Data List / Active Test [08/2014 - ]
WARNING: This page is about a different variant/trim than selected.
- DATA LIST NOTE:
- Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obtained. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
- In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under identical conditions in order to reach an overall judgment by comparing all the items in the Data List.
- Connect the Techstream to the DLC3.
- Start plug-in charging the vehicle.
HINT:
If plug-in charging is started with the power switch on (IG), the power switch will be turned off automatically.
- Turn the power switch on (IG).NOTE:
If the power switch is turned on (IG) during plug-in charging, the power switch will be turned off automatically after several tens of seconds.
- Enter the following menus: Powertrain / Plug-in Control / Data List
- Check the results by referring to the following table.
HINT:
- When reviewing Data List information, try to select only the specific Data List items related to the inspection being performed. If all items are selected when checking the Data List, the interval between updates for each item will be longer, resulting in delayed or incorrect data.
Tester Display Measurement Item/Range Normal Condition Charge Mode Charge mode/
Min.: -128, Max.: 1270: Not charging
2: ChargingCharging Control Status Charge control status/
Min.: -128, Max.: 127- 0:Initial state
- 1:Start
- 2:Charging
- 3:Interrupted
- 4:End
Diagnostic Note:
Progress of charging sequence can be checked.Plug-in Charge Start Signal Power source condition of plug-in charge system/
ON or OFFON: Power ON
OFF: Power OFFDiagnostic Note:
An activation signal generated by the plug-in charge control ECU assembly.HV Control Status HV system control mode (driving/charging)/
Min.: -128, Max.: 127- 0: Unconfirmed (initial state)
- 1: Normal (driving) mode
- 2: Plug-in (charging) mode
On-Board Charger Input Voltage Effective AC voltage (VAC sensor value) input to the electric vehicle charger assembly from the charging inlet/
Min.: 0.0 V, Max.: 6553.5 VAlmost the same as rated voltage On-Board Charger Input Voltage Sensor Offset - Displays offset value of the VAC sensor input voltage (AC voltage) sent from the electric vehicle charger cable assembly to the electric vehicle charger assembly.
- Min.: -500 V, Max.: 500 V
- Rated Electricity Power Supply Rated power for charging when the electric vehicle charger cable assembly is connected/
Min.: -328.00 kW, Max.: 327.67 kW1.44 kW: Rated power AC 100 V
2.00 kW: Rated power AC 200 VDiagnostic Note:
The rated power appropriate for the capacity of the electric vehicle charger assembly is set based on the AC voltage and rated amperage.Charger Output Current Amperage (ICHG sensor value) output from the electric vehicle charger assembly/
Min.: -125.000 A, Max.: 124.996 A- On-Board Charger Current Sensor Voltage Output voltage of the ICHG sensor based on the amperage output from the electric vehicle charger assembly/
Min.: 0.00 V, Max.: 79.99 V1.64 to 2.36 V: Power switch on (IG), electric vehicle charger cable assembly not connected
1.64 to 7.00 V: Plug-in chargingCharger Output Voltage Voltage (VCHG sensor value) output from the electric vehicle charger assembly/
Min.: 0.0 V, Max.: 32767.5 V- On-Board Charger Voltage Sensor Voltage Output voltage of the VCHG sensor based on the voltage output from the electric vehicle charger assembly/
Min.: 0.00 V, Max.: 79.99 V1.72 to 2.22 V: Power switch on (IG), electric vehicle charger cable assembly not connected
1.72 to 6.00 V: Plug-in charging+B Auxiliary battery voltage/
Min.: 0.000 V, Max.: 65.535 VConstant:
10.0 to 15.0 VState of Charge (All Bat) HV battery state of charge/
Min.: 0.0 %, Max.: 100.0 %Constant:
0.0 to 100.0 %Plug-in Charging Request Continuous charging status/
ON or OFFON: Continuous charging
OFF: Other than continuous chargingCPLT Duty Ratio Duty value of CPLT signal generated at the electric vehicle charger cable assembly side (including EVSE (charging station))./
Min.: 0.0 %, Max.: 100.0 %0.0 to 100.0 % Diagnostic Note: - Allowable amperage from EVSE (charging station) can be determined based on CPLT duty. (Allowable amperage [A] = CPLT duty value x 0.6)
- The plug-in charge control ECU assembly commands the electric vehicle charger assembly to limit the amperage (ILMT, etc.) based on CPLT duty value, however the allowable amperage is not exactly the same as the value obtained using the above formula.
CPLT Pulse Time Duration of 1 cycle of CPLT/
Min.: 0 μs, Max.: 65535 μs980 to 1020 μs: CPLT (control pilot signal) generated Diagnostic Note:
Whether a non-standard cable was used can be checked.CPLT Output Voltage CPLT terminal voltage/
Min.: 0.0 V, Max.: 25.5 V8 to 10 V: Connected, not ready to receive power
5 to 7 V: Connected, ready to receive power, indoor charging ventilation not required
3 V: Connected, ready to receive power, indoor charging ventilation required
0 V: Not connected to the EVSE (charging station) system or power unavailableDiagnostic Note:
Charging condition can be determined.Charge Request to Charger Electric vehicle charger assembly activation request/
ON or OFFON: Electric vehicle charger assembly activation requested
OFF: Electric vehicle charger assembly deactivation requestedCurrent Upper Limit Value Upper limit of amperage which can be input from the EVSE (charging station)/
Min.: -328.00 A, Max.: 327.67 A- Diagnostic Note:
ILMT duty value requested by the plug-in charge control ECU assembly to the electric vehicle charger assembly at the ILMT terminal.AC Upper Limit Duty ILMT duty value/
Min.: 0.0 %, Max.: 100.0 %0.0 to 100.0 % Charger State Pulse Duty Ratio Electric vehicle charger assembly charging status indicated by duty/
Min.: 0.0 %, Max.: 100.0 %0.0 to 38.0 %: Stand-by
38.0 to 65.0 %: Ready
65.0 to 100.0 %: Abnormal interruptionCharger State Pulse Time Duration of 1 cycle of Charger State Pulse Duty Ratio/
Min.: 0 ms, Max.: 65535 ms97 to 103 ms Target Charge Power Charging power target value/
Min.: -328.00 kW, Max.: 327.67 kW- Request Charge Power Charging power command sent from the plug-in charge control ECU assembly to the electric vehicle charger assembly/
Min.: -328.00 kW, Max.: 327.67 kW0.00 to 2.00 kW Request Charge Power Duty Ratio Charging power duty value/
Min.: 0.0 %, Max.: 100.0 %15.0 to 61.7 % Offset Value of Charge Power Request Charging power compensation value/
Min.: -328.00 kW, Max.: 327.67 kW- Calculated Value of Charge Power Input Calculated value of monitoring power at the HV battery/
Min.: -328.00 kW, Max.: 327.67 kW- Calculated Value of Charge Power Output Calculated value of power supplied from the electric vehicle charger assembly/
Min.: -328.00 kW, Max.: 327.67 kW- CHRB Status CHRB relay status/
ON or OFFON: CHRB relay closed
OFF: CHRB relay openCHRG Status CHRG relay status/
ON or OFFON: CHRG relay closed
OFF: CHRG relay openCHRB Control Status Request sent to CHRB relay excitation cable/
ON or OFFON: CHRB relay close requested
OFF: CHRB relay open requestedCHRG Control Status Request sent to CHRG relay excitation cable/
ON or OFFON: CHRG relay close requested
OFF: CHRG relay open requestedVoltage with Charge Cable Connected PISW terminal voltage used for checking electric vehicle charger cable assembly connection condition/
Min.: 0.00 V, Max.: 79.99 V1.20 to 1.80 V: Electric vehicle charger cable assembly inserted
4.00 to 4.50 V: Electric vehicle charger cable assembly not inserted
2.50 to 3.10 V: Electric vehicle charger cable assembly inserted and the latch release button (PI switch) engagedCharge Cable Inserted Electric vehicle charger cable assembly insertion condition without considering ON/OFF of the latch release button (PI switch)/
ON or OFFON: Electric vehicle charger cable assembly inserted
OFF: Electric vehicle charger cable assembly not insertedCharge Cable Engaged Electric vehicle charger cable assembly latch release button (PI switch) condition/
ON or OFFON: Latch release button (PI switch) released when electric vehicle charger cable assembly inserted
OFF: Latch release button (PI switch) engaged when electric vehicle charger cable assembly insertedCharge Lid Turn Off Light Status Charging inlet light turn off request/
ON or OFFON: Charging inlet light not illuminated
OFF: Charging inlet light illuminatedDiagnostic Note:
A turn off request is sent when the electric vehicle charger cable assembly is connected or the power switch is turned on (READY).
Check of the charging inlet light function can be performed together with checking the results of "Charge Cable Inserted" and "Charge Cable Engaged".Charge Lid SW Charging port lid switch status/
ON or OFFON: Charging port lid closed
OFF: Charging port lid openStates of Pre Air-Conditioner on Battery Remote climate control system operation condition/
ON or OFFON: Remote climate control system operating
OFF: Remote climate control system not operatingCharge Indicate Light Status Charging indicator illumination status/
Min.: 0, Max.: 255- 0: Charging Indicator turned off
- 1: Charging Indicator blinking in short intervals
- 2: Charging indicator blinking in long intervals
- 3: Charging indicator illuminated
Timer Lamp Light Request Charging timer indicator illumination status/
ON or OFFON: Charging timer indicator illuminated
OFF: Charging timer indicator not illuminatedCharging Timer SW Charging timer switch condition/
ON or OFFON: Charging timer switch operated
OFF: Charging timer switch not operatedTimer Setting Status(Send) Charging timer setting status sent from plug-in charge control ECU assembly to the meter ECU/
No Timer Setting, Start Timer Being Set, Start Timer Setting Being Changed, Start Timer Set, End Timer Being Set, End Timer Setting Being Changed or End Timer Set- Timer Setting Status(Received) Charging timer setting status sent from the meter ECU to the plug-in charge control ECU assembly/
No Timer Setting, Start Timer Being Set, Start Timer Setting Being Changed, Start Timer Set, End Timer Being Set, End Timer Setting Being Changed or End Timer Set- Time until Timer Charging Start Time remaining until charging starts/
Min.: 0 min, Max.: 65535 min- Timer Setting Time Time set by time setting switch/
Min.: 0, Max.: 2550- Current Time Current time on the meter clock of the vehicle/
Min.: 0, Max.: 65535- Number of Timer Settings Accumulated number of times timer has been set/
Min.: 0, Max.: 255- Timer Setting Cancel Request(DCM) Timer charging cancellation request from DCM (telematics transceiver)/
ON or UnknownON: Timer charging cancellation requested Timer Setting Cancel Request(WCG) Timer charging cancellation request from WCG/
ON or UnknownON: Timer charging cancellation requested Communication Status with Meter Communication status with the meter ECU/
Normal or AbnormalNormal: Communication exists
Abnormal: Communication does not existTime when Timer Setting Canceled (Latest) Time when timer charging was last canceled/
Min.: 0, Max.: 2550- Number of Timer Settings when Timer Setting Canceled (Latest) Accumulated number of times the timer was set when timer charging was last canceled/
Min.: 0, Max.: 255- Cause of Timer Cancel (Latest) Reasons for when timer charging was last canceled/
Unknown, Timer SW Stuck ON, Meter Comm Malf, ECU Malf, Timer Count Malf, Charge Incapable, Request by DCM, Request by WCG, Timer SW Op, Normal Charge or Other- Time when Timer Setting Canceled (2nd Latest) Time when timer charging was canceled once before the last/
Min.: 0, Max.: 2550- Number of Timer Settings when Timer Setting Canceled (2nd Latest) Accumulated number of times the timer was set when timer charging was canceled once before the last/
Min.: 0, Max.: 255- Cause of Timer Cancel (2nd Latest) Reasons for when timer charging was canceled once before last/
Unknown, Timer SW Stuck ON, Meter Comm Malf, ECU Malf, Timer Count Malf, Charge Incapable, Request by DCM, Request by WCG, Timer SW Op, Normal Charge or Other- Time when Timer Setting Canceled (3rd Latest) Time when timer charging was canceled twice before last/
Min.: 0, Max.: 2550- Number of Timer Settings when Timer Setting Canceled (3rd Latest) Accumulated number of times the timer was set when timer charging was canceled twice before last/
Min.: 0, Max.: 255- Cause of Timer Cancel (3rd Latest) Reasons for when timer charging was canceled twice before last/
Unknown, Timer SW Stuck ON, Meter Comm Malf, ECU Malf, Timer Count Malf, Charge Incapable, Request by DCM, Request by WCG, Timer SW Op, Normal Charge or Other- Time when Timer Setting Canceled (4th Latest) Time when timer charging was canceled 3 times before last/
Min.: 0, Max.: 2550- Number of Timer Settings when Timer Setting Canceled (4th Latest) Accumulated number of times the timer was set when timer charging was canceled 3 times before last/
Min.: 0, Max.: 255- Cause of Timer Cancel (4th Latest) Reasons for when timer charging was canceled 3 times before last/
Unknown, Timer SW Stuck ON, Meter Comm Malf, ECU Malf, Timer Count Malf, Charge Incapable, Request by DCM, Request by WCG, Timer SW Op, Normal Charge or Other- Time when Timer Setting Canceled (5th Latest) Time when timer charging was canceled 4 times before last/
Min.: 0, Max.: 2550- Number of Timer Settings when Timer Setting Canceled (5th Latest) Accumulated number of times the timer was set when timer charging was canceled 4 times before last/
Min.: 0, Max.: 255- Cause of Timer Cancel (5th Latest) Reasons for when timer charging was canceled 4 times before last/
Unknown, Timer SW Stuck ON, Meter Comm Malf, ECU Malf, Timer Count Malf, Charge Incapable, Request by DCM, Request by WCG, Timer SW Op, Normal Charge or Other- Number of Charges Suspended(ECU) Accumulated number of times charging was interrupted due to ECU related causes/
Min.: 0, Max.: 65535- Diagnostic Note:
When a temporary communication error occurs in the plug-in charge control ECU assembly or auxiliary battery voltage drops.Number of Charges Suspended(Charger) Accumulated number of times charging was interrupted due to electric vehicle charger assembly related causes/
Min.: 0, Max.: 65535- Diagnostic Note:
When a VCHG sensor wire temporary malfunction occurs.Number of Charges Suspended(AC Line) Accumulated number of times charging was interrupted due to AC line related causes/
Min.: 0, Max.: 65535- Diagnostic Note:
Due to AC line interruption, CPLT unexpected pulse, etc.Number of Charges Suspended(Battery) Accumulated number of times charging was interrupted due to HV battery related causes/
Min.: 0, Max.: 65535- Diagnostic Note:
When temporary cancellation of charging is judged by the hybrid battery control.Number of Charges Canceled(Charge Connector Not Engaged Properly) Accumulated number of times charging was canceled due to improper engagement of the charge connector/
Max.: 0, Max.: 255- Number of Charges Canceled(Power Failure) Accumulated number of times charging canceled due to improper engagement of the charge connector/
Max.: 0, Max.: 255- Number of Charges Canceled(Battery Temperature) Accumulated number of times charging canceled due to HV battery related causes/
Max.: 0, Max.: 255- Number of Charges Canceled(+B) Accumulated number of times charging canceled due to excessive auxiliary battery load/
Max.: 0, Max.: 255- Number of Charges Delayed(Charge Control Value Low) Accumulated number of times charging delayed due to HV battery related causes/
Max.: 0, Max.: 255- Number of Charges Delayed(Charger Output Low) Accumulated number of times charging delayed due to electric vehicle charger assembly related causes/
Max.: 0, Max.: 255- Number of Charges Delayed(+B) Accumulated number of times charging delayed due to excessive auxiliary battery load/
Max.: 0, Max.: 255- DTC Clear Warm Up Number of times the engine is warmed up after clearing DTCs/
Min.: 0, Max.: 255- Diagnostic Note:
MIL OFF, engine coolant temperature increases from below 22°C (71.6°F) before starting the engine to above 70°C (158°F) after starting the engine: Increases onceDTC Clear Run Distance Drive distance after clearing DTCs/
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)- DTC Clear Min Elapsed time after clearing DTCs/
Min.: 0 min, Max.: 65535 min- Engine Coolant Temp Engine coolant temperature/
Min.: -40°C (-40°F), Max.: 140°C (284°F)Cold start→Fully warmed up:
Gradually rises
After warming up:
80 to 100°C (176 to 212°F)Engine Revolution Engine speed/
Min.: 0 rpm, Max.: 16383 rpmWhile idling after the engine is warmed up and inspection mode:
Approximately 1000 rpm
While driving at a constant speed:
No significant fluctuationVehicle Spd Vehicle speed/
Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)Vehicle stopped:
0 km/h (0 mph)
While driving at a constant speed:
No significant fluctuationEngine Run Time Elapsed time after starting engine/
Min.: 0 s, Max.: 65535 sElapsed time after starting engine Diagnostic Note:
After the power switch is turned on (READY), elapsed time from initial engine start until the power switch is turned off.Calculate Load Calculated load/
Min.: 0.0 %, Max.: 100.0 %Engine idling with warm engine, air conditioner off, park (P) and inspection mode selected:
11.0 to 22.0 %
Engine speed of 2500 rpm, air conditioner off, park (P) and inspection mode selected:
12.1 to 18.2 %Throttle Position Throttle position sensor/
Min.: 0.0 %, Max.: 100.0 %Throttle valve fully closed:
10.0 to 24.0 %MIL on Engine Run Time Driving time after a malfunction occurs/
Min.: 0 min, Max.: 65535 min- MIL Status MIL status/
ON or OFFMIL ON: ON MIL on Run Distance Travel distance after a malfunction occurs/
Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)- OBD Requirements OBD requirements - Number of Emission DTC The number of emission DTCs - Complete Parts Monitor Comprehensive component monitor/
COMPL or INCMPL- Component Monitor CMPL Comprehensive component monitor/
Disable or Enable- Num of Current Code The number of current DTCs/
Min.: 0, Max.: 255- Num of History Code The number of history DTCs/
Min.: 0, Max.: 255- Check Mode Check Mode/
ON or OFF-