Typical Enabling Conditions
P0715:
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
P0717:
| The monitor will run whenever this DTC is not present. | P0746, P0748: Shift solenoid valve SL1 P0776, P0778: Shift solenoid valve SL2 P0796, P0798: Shift solenoid valve SL3 P2808, P2810: Shift solenoid valve SL2 |
| Shift change | Shift change is completed before starting next shift change operation |
| TCM selected gear | 2nd, 3rd, 4th, 5th or 6th |
| Output shaft speed | 1000 rpm or more |
| Park/neutral position switch | OFF |
| R switch | OFF |
| Engine | Running |
| Transmission range switch circuit fail (P0705) | Not detected |
| Turbine speed sensor range check fail (P0715) | Not detected |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |