Key Cannot be Removed or Inserted [06/2016 - ]: Procedure
- CHECK WIRE HARNESS AND CONNECTOR (ACC VOLTAGE)
- Disconnect the D42 control unit relay assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition D42-6 (ACC) - Body ground Ignition switch ON 11 to 14 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to control unit relay assembly)
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 2
- Disconnect the D42 control unit relay assembly connector.
- CHECK WIRE HARNESS AND CONNECTOR (CONTROL UNIT RELAY ASSEMBLY - BODY GROUND)
- Disconnect the D42 control unit relay assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D42-1 (E) - Body ground Always Below 1 Ω
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 3
- INSPECT P SWITCH (FLOOR SHIFT LEVER HOUSING)
- Inspect the P switch (floor shift lever housing) (Refer to PROCEDURE - Step 1 ).
Result:
NG
REPLACE P SWITCH (FLOOR SHIFT LEVER HOUSING)
(Refer to DISASSEMBLY [06/2016 - ] )
Result:
OK
See step 4
- CHECK WIRE HARNESS AND CONNECTOR (CONTROL UNIT RELAY ASSEMBLY - P SWITCH (FLOOR SHIFT LEVER HOUSING)
- Disconnect the D42 control unit relay assembly connector.
- Disconnect the D28 P switch (floor shift lever housing) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
Tester Connection Condition Specified Condition D42-4 (P) - D28-1 (P) Always Below 1 Ω Standard Resistance (Check for Short)
Tester Connection Condition Specified Condition D42-4 (P) or D28-1 (P) - Body ground Always 10 kΩ or higher
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 5
- CHECK WIRE HARNESS AND CONNECTOR (P SWITCH (FLOOR SHIFT LEVER HOUSING) - BODY GROUND)
- Disconnect the D28 P switch (floor shift lever housing) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D28-3 (E) - Body ground Always Below 1 Ω
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 6
- INSPECT KEY INTER LOCK SOLENOID
- Disconnect the D60 key inter lock solenoid connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 13.05 to 15.95 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Key Inter Lock Solenoid)
Result:
NG
REPLACE KEY INTER LOCK SOLENOID
(Refer to DISASSEMBLY [06/2016 - 03/2017] Refer to DISASSEMBLY [03/2017 - ] )
Result:
OK
See step 7
- Disconnect the D60 key inter lock solenoid connector.
- CHECK WIRE HARNESS AND CONNECTOR (CONTROL UNIT RELAY ASSEMBLY - KEY INTER LOCK SOLENOID)
- Disconnect the D42 control unit relay assembly connector.
- Disconnect the D60 key inter lock solenoid connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
Tester Connection Condition Specified Condition D42-5 (KLS+) - D60-2 Always Below 1 Ω Standard Resistance (Check for Short)
Tester Connection Condition Specified Condition D42-5 (KLS+) or D60-2 - Body ground Always 10 kΩ or higher
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 8
- CHECK WIRE HARNESS AND CONNECTOR (KEY INTER LOCK SOLENOID - BODY GROUND)
- Disconnect the D60 key inter lock solenoid connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition D60-1 - Body ground Always Below 1 Ω
Result:
OK
REPLACE CONTROL UNIT RELAY ASSEMBLY
(Refer to REMOVAL [06/2016 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR