DTC P104A: VALVEMATIC SDOWN Circuit [08/2016 - ]: Description
WARNING: This page is about a different variant/trim than selected.
The ECM turns the power supply to the continuously variable valve lift controller assembly on/off. Normally, when the ignition switch is ON, +B voltage is constantly supplied to the continuously variable valve lift controller assembly. However, when a malfunction is detected in the VALVEMATIC system, the ECM turns the power supply to the continuously variable valve lift controller assembly off. The power supply is turned on/off through the shutdown (SDWN) signal line between the ECM and continuously variable valve lift controller assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P104A | VALVEMATIC SDOWN Circuit | Shutdown (SDWN) signal line has a short circuit to +B or ground (1 trip detection logic):
|
|
Comes on | DTC stored | DTC for Mexico Models - Applies |