Fail-Safe Chart [08/2016 - ]
- DISPLACEMENT OF NON-DETECTION RANGE TO THE OPENING DIRECTION
- If the power window position or learned value is abnormal, the following power window operations will prohibited.POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
Power Window Operation Condition Ignition switch ON Ignition switch off
(Key-off operation permitted)Ignition switch off
(Key-off operation prohibited)Manual up (Driver door window) • X X Manual down (Driver door window) • X X Auto up (Driver door window) X X X Auto down (Driver door window) X X X HINT:
- •: Operates without jam protection/catch protection
- X: Operation prohibited
Fail-safe deactivation condition
- When the pulse sensor is normal, to deactivate fail-safe mode, pull up the power window switch to the auto up position and hold it for at least 1 second to fully close the power window from the fully open position. As a result, the auto up/down function will return.
- If the power window position or learned value is abnormal, the following power window operations will prohibited.
- INITIAL FAILURE
- During initialization, if the door glass position or initialization complete status cannot be properly read from the non-volatile memory, the following power window operations will prohibited.POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
Power Window Operation Condition Ignition switch ON Ignition switch off
(Key-off operation permitted)Ignition switch off
(Key-off operation prohibited)Manual up (Driver door window) • X X Manual down (Driver door window) • X X Auto up (Driver door window) X X X Auto down (Driver door window) X X X HINT:
- •: Operates without jam protection/catch protection
- X: Operation prohibited
Fail-safe deactivation condition
- Initialize the power window regulator motor assembly.
Refer to INITIALIZATION [08/2016 - ]
- During initialization, if the door glass position or initialization complete status cannot be properly read from the non-volatile memory, the following power window operations will prohibited.
- LIN COMMUNICATION FAILURE
- If the LIN communication system is malfunctioning (communication stop), the power window control system prohibits operation as follows.POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
Power Window Operation Condition Always Manual up •* Manual down • Auto up X Auto down X HINT:
- •: Operates without jam protection/catch protection
- X: Operation prohibited
- *: Jam protection/catch protection can operate.
Fail-safe deactivation condition
- Check LIN communication system.
- If the LIN communication system is malfunctioning (communication stop), the power window control system prohibits operation as follows.
- PULSE FAILURE AND LIN COMMUNICATION FAILURE
- If the LIN communication system is malfunctioning (communication stop) and the pulse sensor is malfunctioning, the following power window operations are prohibited.POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
Power Window Operation Condition Always Manual up X Manual down X Auto up X Auto down X HINT:
- X: Operation prohibited
- Switch on the door:
When the jam protection function does not operate due to LIN communication failure, the manual up and auto up functions will not operate as the state of the IG signal is unknown.
- Remote switch operation:
Operation is not possible during LIN communication failure.
- If the LIN communication system is malfunctioning (communication stop) and the pulse sensor is malfunctioning, the following power window operations are prohibited.
- DISPLACEMENT OF NON-DETECTION RANGE TO THE OPENING DIRECTION AND LIN COMMUNICATION FAILURE / INITIAL FAILURE AND LIN COMMUNICATION FAILURE
- If the LIN communication system is malfunctioning and the power window position and learned value are abnormal, or the LIN communication system is malfunctioning and the power window position or initialization complete status cannot be properly read from the non-volatile memory during initialization, the following power window operations are prohibited.POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
Power Window Operation Condition Always Manual up •* Manual down • Auto up X Auto down X HINT:
- •: Operates without jam protection/catch protection
- X: Operation prohibited
- *: Jam protection/catch protection can operate and window reverses upon reaching the fully closed position.
- Remote switch operation:
Operation is not possible during LIN communication failure.
- If the LIN communication system is malfunctioning and the power window position and learned value are abnormal, or the LIN communication system is malfunctioning and the power window position or initialization complete status cannot be properly read from the non-volatile memory during initialization, the following power window operations are prohibited.