Jam Protection Function does not Operate [12/2013 - ]: Procedure
- PERFORM INITIALIZATION (APPLICABLE LOCATION)
- Initialize the power window regulator motor assembly (applicable location).
Refer to INITIALIZATION [12/2013 - ]
NEXT
- Initialize the power window regulator motor assembly (applicable location).
- CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP / DOWN FUNCTION)
- Check if the power window auto up and down function operates normally.
Refer to OPERATION CHECK [12/2013 - ]
OK
Auto up and down function is normal.
Result
Proceed to OK NG
Result: 2
NG
GO TO OTHER PROBLEM (Proceed to Problem Symptoms Table). Refer to PROBLEM SYMPTOMS TABLE [12/2013 - ]
Result: 1
OK
See step 3
- Check if the power window auto up and down function operates normally.
- CHECK JAM PROTECTION FUNCTION OPERATING RANGE
- Check if the jam protection function operates normally for the applicable power window.
HINT:
The jam protection function will not operate within 4 mm (0.157 in.) of the fully closed position.
OK
Jam protection function operates normally.
Result
Result Proceed to OK A NG (Driver door power window) B NG (Front passenger door power window)
Result: 1
A
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result: 2
B
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (FOR DRIVER DOOR OR FRONT PASSENGER DOOR). Refer to REMOVAL [12/2013 - ]
- Check if the jam protection function operates normally for the applicable power window.