Freeze Frame Data [06/2015 - ]
- CHECK FREEZE FRAME DATA
HINT:
The transmission control ECU assembly records vehicle and driving condition information as freeze frame data the moment a DTC is stored. Freeze frame data can help determine the vehicle conditions when the malfunction occurred and help duplicate conditions when troubleshooting.
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Transmission Control / Trouble Codes.
- Select a DTC in order to display its freeze frame data.
Body Electrical > Transmission Control > Trouble Codes
- LIST OF FREEZE FRAME DATA
Body Electrical > Transmission Control
Tester Display Measurement Item Reference Value Diagnostic Note Shift Pos Display (P) Shift position display (P) ON / OFF - Shift Pos Display (Not P) Shift position display (not P) ON / OFF - Master Caution Display Master caution display Disp / Nondisp - PSW Indicator Mode PSW indicator mode OFF / ON - U Phase Voltage Value U phase voltage value 0 to 39 V - V Phase Voltage Value V phase voltage value 0 to 39 V - W Phase Voltage Value W phase voltage value 0 to 39 V - Battery Voltage Value BATT voltage value 0 to 19 V - IG (+B) Voltage Value IG (+B) voltage value 0 to 19 V - Cmplte of Learn Lck Pos Completion of lock position learning OK / NG - Cmplte of Learn Unlck Pos Completion of unlock position learning OK / NG - # of Trip Cuntr after Learn Counter for number of trip after learning 0 to 65535 - Main Relay for Motor Drive P CON relay (transaxle parking lock control relay) for motor drive ON / OFF - U Phase Crnt-Carry Status U phase current-carrying status ON / OFF - V Phase Crnt-Carry Status V phase current-carrying status ON / OFF - W Phase Crnt-Carry Status W phase current-carrying status ON / OFF - U Phase Voltage Status U phase voltage status ON / OFF - V Phase Voltage Status V phase voltage status ON / OFF - W Phase Voltage Status W phase voltage status ON / OFF - Battery Voltage Status BATT voltage status ON / OFF - IG (+B) Phase Vol Status IG (+B) phase voltage status ON / OFF - ACC Condition Signal ACC condition signal ON / OFF - Init Drv Cntrl Completed Initial drive control completed OK / NG - Cmplte of Detct Lck Pos Completion of detecting lock position OK / NG - Cmplte of Detct Unlck Pos Completion of detecting unlock position OK / NG - P/Not P Move Shft Range P/Not P movable shift range Set / Unset - Main Relay P CON relay (transaxle parking lock control relay) Normal / Abnoml - Current flag record Current flag record ON / OFF - Fail Rank Fail rank 0 to 255 - Number of Trip after Low Voltage Actuator Abnormal Number of trips since shift control actuator assembly did not operate due to decrease in auxiliary battery voltage 0 to 31 - Low Voltage Actuator Abnormal History History of shift control actuator assembly not operating due to decrease in auxiliary battery voltage ON / OFF - Detail Information 1 - - - Detail Information 2 - - - Detail Information 3 - - - Detail Information 4 - - - Detail Information 5 - - - Detail Information 6 - - - Detail Information 7 - - - Detail Information 8 - - - Detail Information 9 - - - Detail Information 10 - - - Detail Information 11 - - - Detail Information 12 - - - Detail Information 13 - - - Detail Information 14 - - - Detail Information 15 - - - Detail Information 16 - - - Detail Information 17 - - - Detail Information 18 - - - Detail Information 19 - - - Detail Information 20 - - - Detail Information 21 - - - Detail Information 22 - - - Detail Information 23 - - - Detail Information 24 - - - Detail Information 25 - - - Detail Information 26 - - - Detail Information 27 - - - Detail Information 28 - - - Detail Information 29 - - - Detail Information 30 - - - Detail Information 31 - - - Detail Information 32 - - - Detail Information 33 - - -