Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated) [11/2015 - ]: Procedure
- PERFORM INITIALIZATION (DRIVER DOOR WINDOW MOTOR)
- Initialize the power window regulator motor assembly LH (for driver door) (Refer to INITIALIZATION [11/2015 - 06/2017] Refer to INITIALIZATION [06/2017 - ] ).
NEXT
See step 2
- CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION (FOR DRIVER DOOR))
- Check that the driver door power window moves when the auto up and down functions of the power window regulator master switch assembly are operated (Refer to OPERATION CHECK [11/2015 - 06/2017]
Refer to OPERATION CHECK [06/2017 - ]
).
OK
Driver door power window auto up and down function is normal.
Result:
OK
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result:
NG
See step 3
- Check that the driver door power window moves when the auto up and down functions of the power window regulator master switch assembly are operated (Refer to OPERATION CHECK [11/2015 - 06/2017]
Refer to OPERATION CHECK [06/2017 - ]
).
- CHECK WINDOW GLASS SLIDING MOVEMENT (FOR DRIVER DOOR)
- Remove the window regulator.
- Install the window glass onto the door glass run.
- Check if the door window regulator operates smoothly.
- Check that the window glass slides smoothly when sliding it up by hand.
OK
Door window glass slides smoothly.
HINT:
Ensure the following:
- The window glass fits with the glass run without improper contact or deformation.
- Foreign matter is not caught in the glass run.
WARNING:Perform initialization again.
Result:
OK
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (FOR DRIVER DOOR)
Refer to REMOVAL [11/2015 - ] )
Result:
NG
FIT WINDOW GLASS CORRECTLY (REMOVE FOREIGN MATTER CAUSING IMPROPER FIT OR REPLACE PARTS)