DTC B1796: Sleep Operation Failure of Occupant Classification ECU [11/2015 - ]: Procedure
- REPLACE OCCUPANT DETECTION ECU
- Turn the ignition switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Replace the occupant detection ECU (Refer to REMOVAL [11/2015 - ] ).
- Connect the cable to the negative (-) auxiliary battery terminal.
NEXT
See step 2
- PERFORM ZERO POINT CALIBRATION AND SENSITIVITY CHECK
- Using the Techstream, perform Zero Point Calibration and Sensitivity Check (Refer to INITIALIZATION [11/2015 - 06/2017]
NEXT