Monitor Description
The ECM illuminates the MIL and stores a DTC when either one of the following conditions, which could cause emission deterioration, is detected (2 trip detection logic).
- Within the first 1000 crankshaft revolutions after the engine starts, an excessive number of misfires (approximately 10 to 50 misfires per 1000 crankshaft revolutions) occurs once.
The ECM flashes the MIL (immediate detection logic) and stores a DTC (2 trip detection logic) when either one of the following conditions, which could cause damage to the three-way catalytic converter, is detected.
- At a high engine speed, a sufficient amount of misfires to damage the catalyst occurring within 200 crankshaft revolutions is detected once.
- At a normal engine speed, a sufficient amount of misfires to damage the catalyst occurring within 200 crankshaft revolutions is detected 3 times.