Hybrid Battery System
HYBRID BATTERY SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [09/2016 - 12/2018]
| DTC Code | Description |
|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open |
| P060629 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message |
| P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060A87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message |
| P060B16 | Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold |
| P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure |
| P062F44 | Hybrid/EV Battery Energy Control Module EEPROM Data Memory Failure |
| P062F46 | Hybrid/EV Battery Energy Control Module EEPROM Calibration / Parameter Memory Failure |
| P0A1D94 | Hybrid/EV Powertrain Control Module Unexpected Operation |
| P0A8111 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground |
| P0A8115 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open |
| P0A8196 | Hybrid/EV Battery Cooling Fan 1 Component Internal Failure |
| P0A9563 | High Voltage Fuse Accumulated Load History |
| P0A9611 | Hybrid/EV Battery Cooling Fan 2 Circuit Short to Ground |
| P0A9615 | Hybrid/EV Battery Cooling Fan 2 Circuit Short to Auxiliary Battery or Open |
| P0A9696 | Hybrid/EV Battery Cooling Fan 2 Component Internal Failure |
| P0A9B11 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Ground |
| P0A9B15 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0A9B1C | Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range |
| P0A9B2A | Hybrid/EV Battery Temperature Sensor "A" Signal Stuck In Range |
| P0AAC11 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground |
| P0AAC15 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0AB111 | Hybrid/EV Battery Air Temperature Sensor "B" Circuit Short to Ground |
| P0AB115 | Hybrid/EV Battery Air Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open |
| P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground |
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range |
| P0AC511 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Ground |
| P0AC515 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open |
| P0AC51C | Hybrid/EV Battery Temperature Sensor "B" Voltage Out of Range |
| P0AC52A | Hybrid/EV Battery Temperature Sensor "B" Signal Stuck In Range |
| P0ACA11 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Ground |
| P0ACA15 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P0ACA1C | Hybrid/EV Battery Temperature Sensor "C" Voltage Out of Range |
| P0ACA2A | Hybrid/EV Battery Temperature Sensor "C" Signal Stuck In Range |
| P0AE811 | Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Ground |
| P0AE815 | Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Auxiliary Battery or Open |
| P0AE81C | Hybrid/EV Battery Temperature Sensor "D" Voltage Out of Range |
| P0AE82A | Hybrid/EV Battery Temperature Sensor "D" Signal Stuck In Range |
| P0B0E11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground |
| P0B0E15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open |
| P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure |
| P0BC211 | Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Ground |
| P0BC215 | Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Auxiliary Battery or Open |
| P0BC21C | Hybrid/EV Battery Temperature Sensor "E" Voltage Out of Range |
| P0BC22A | Hybrid/EV Battery Temperature Sensor "E" Signal Stuck In Range |
| P0C3000 | Hybrid/EV Battery State of Charge High |
| P0C3311 | Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Ground |
| P0C3315 | Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Auxiliary Battery or Open |
| P0C331C | Hybrid/EV Battery Temperature Sensor "F" Voltage Out of Range |
| P0C332A | Hybrid/EV Battery Temperature Sensor "F" Signal Stuck In Range |
| P0C7C11 | Hybrid/EV Battery Temperature Sensor "G" Circuit Short to Ground |
| P0C7C15 | Hybrid/EV Battery Temperature Sensor "G" Circuit Short to Auxiliary Battery or Open |
| P0C7C1C | Hybrid/EV Battery Temperature Sensor "G" Voltage Out of Range |
| P0C7C2A | Hybrid/EV Battery Temperature Sensor "G" Signal Stuck In Range |
| P0C8111 | Hybrid/EV Battery Temperature Sensor "H" Circuit Short to Ground |
| P0C8115 | Hybrid/EV Battery Temperature Sensor "H" Circuit Short to Auxiliary Battery or Open |
| P0C811C | Hybrid/EV Battery Temperature Sensor "H" Voltage Out of Range |
| P0C812A | Hybrid/EV Battery Temperature Sensor "H" Signal Stuck In Range |
| P0C8811 | Hybrid/EV Battery Temperature Sensor "I" Circuit Short to Ground |
| P0C8815 | Hybrid/EV Battery Temperature Sensor "I" Circuit Short to Auxiliary Battery or Open |
| P0C881C | Hybrid/EV Battery Temperature Sensor "I" Voltage Out of Range |
| P0C882A | Hybrid/EV Battery Temperature Sensor "I" Signal Stuck In Range |
| P0C8D11 | Hybrid/EV Battery Temperature Sensor "J" Circuit Short to Ground |
| P0C8D15 | Hybrid/EV Battery Temperature Sensor "J" Circuit Short to Auxiliary Battery or Open |
| P0C8D1C | Hybrid/EV Battery Temperature Sensor "J" Voltage Out of Range |
| P0C8D2A | Hybrid/EV Battery Temperature Sensor "J" Signal Stuck In Range |
| P0C9211 | Hybrid/EV Battery Temperature Sensor "K" Circuit Short to Ground |
| P0C9215 | Hybrid/EV Battery Temperature Sensor "K" Circuit Short to Auxiliary Battery or Open |
| P0C921C | Hybrid/EV Battery Temperature Sensor "K" Voltage Out of Range |
| P0C922A | Hybrid/EV Battery Temperature Sensor "K" Signal Stuck In Range |
| P0C9711 | Hybrid/EV Battery Temperature Sensor "L" Circuit Short to Ground |
| P0C9715 | Hybrid/EV Battery Temperature Sensor "L" Circuit Short to Auxiliary Battery or Open |
| P0C971C | Hybrid/EV Battery Temperature Sensor "L" Voltage Out of Range |
| P0C972A | Hybrid/EV Battery Temperature Sensor "L" Signal Stuck In Range |
| P0CA811 | Hybrid/EV Battery Temperature Sensor "M" Circuit Short to Ground |
| P0CA815 | Hybrid/EV Battery Temperature Sensor "M" Circuit Short to Auxiliary Battery or Open |
| P0CA81C | Hybrid/EV Battery Temperature Sensor "M" Voltage Out of Range |
| P0CA82A | Hybrid/EV Battery Temperature Sensor "M" Signal Stuck In Range |
| P0CAD11 | Hybrid/EV Battery Temperature Sensor "N" Circuit Short to Ground |
| P0CAD15 | Hybrid/EV Battery Temperature Sensor "N" Circuit Short to Auxiliary Battery or Open |
| P0CAD1C | Hybrid/EV Battery Temperature Sensor "N" Voltage Out of Range |
| P0CAD2A | Hybrid/EV Battery Temperature Sensor "N" Signal Stuck In Range |
| P0CB211 | Hybrid/EV Battery Temperature Sensor "O" Circuit Short to Ground |
| P0CB215 | Hybrid/EV Battery Temperature Sensor "O" Circuit Short to Auxiliary Battery or Open |
| P0CB21C | Hybrid/EV Battery Temperature Sensor "O" Voltage Out of Range |
| P0CB22A | Hybrid/EV Battery Temperature Sensor "O" Signal Stuck In Range |
| P0D0A11 | Hybrid/EV Battery Charging System Positive Contactor Control Circuit Short to Ground |
| P0D0A15 | Hybrid/EV Battery Charging System Positive Contactor Control Circuit Short to Auxiliary Battery or Open |
| P0D1111 | Hybrid/EV Battery Charging System Negative Contactor Control Circuit Short to Ground |
| P0D1115 | Hybrid/EV Battery Charging System Negative Contactor Control Circuit Short to Auxiliary Battery or Open |
| P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance |
| P0E6D11 | Hybrid/EV Battery Charging System Precharge Contactor Control Circuit Short to Ground |
| P0E6D15 | Hybrid/EV Battery Charging System Precharge Contactor Control Circuit Short to Auxiliary Battery or Open |
| P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range |
| P1A051C | Hybrid Battery Stack 3 Cell Voltage Detection Voltage Out of Range |
| P1A0A1C | Hybrid Battery Stack 4 Cell Voltage Detection Voltage Out of Range |
| P1A101C | Hybrid Battery Stack 5 Cell Voltage Detection Voltage Out of Range |
| P1A6017 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold |
| P1A6116 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold |
| P1A6317 | Hybrid/EV Battery Stack 3 Cell Circuit Voltage Above Threshold |
| P1A6416 | Hybrid/EV Battery Stack 3 Cell Circuit Voltage Below Threshold |
| P1A6617 | Hybrid/EV Battery Stack 4 Cell Circuit Voltage Above Threshold |
| P1A6716 | Hybrid/EV Battery Stack 4 Cell Circuit Voltage Below Threshold |
| P1A6917 | Hybrid/EV Battery Stack 5 Cell Circuit Voltage Above Threshold |
| P1A6A16 | Hybrid/EV Battery Stack 5 Cell Circuit Voltage Below Threshold |
| P1A8000 | Hybrid/EV Battery Stack 1 Delta SOC High |
| P1A8100 | Hybrid/EV Battery Stack 1 Delta SOC High (Extreme) |
| P1A8500 | Hybrid/EV Battery Stack 2 Delta SOC High |
| P1A8600 | Hybrid/EV Battery Stack 2 Delta SOC High (Extreme) |
| P1A8A00 | Hybrid/EV Battery Stack 3 Delta SOC High |
| P1A8B00 | Hybrid/EV Battery Stack 3 Delta SOC High (Extreme) |
| P1A9000 | Hybrid/EV Battery Stack 4 Delta SOC High |
| P1A9100 | Hybrid/EV Battery Stack 4 Delta SOC High (Extreme) |
| P1A9500 | Hybrid/EV Battery Stack 5 Delta SOC High |
| P1A9600 | Hybrid/EV Battery Stack 5 Delta SOC High (Extreme) |
| P1AC413 | Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open |
| P1AC49E | Hybrid/EV Battery Stack 1 Current Interrupt Device Stuck On |
| P1AC513 | Hybrid/EV Battery Stack 2 Current Interrupt Device Circuit Open |
| P1AC59E | Hybrid/EV Battery Stack 2 Current Interrupt Device Stuck On |
| P1AC613 | Hybrid/EV Battery Stack 3 Current Interrupt Device Circuit Open |
| P1AC69E | Hybrid/EV Battery Stack 3 Current Interrupt Device Stuck On |
| P1AC713 | Hybrid/EV Battery Stack 4 Current Interrupt Device Circuit Open |
| P1AC79E | Hybrid/EV Battery Stack 4 Current Interrupt Device Stuck On |
| P1AC813 | Hybrid/EV Battery Stack 5 Current Interrupt Device Circuit Open |
| P1AC89E | Hybrid/EV Battery Stack 5 Current Interrupt Device Stuck On |
| P1AFC00 | System Voltage (AM) Circuit Voltage Below Threshold |
| P1AFD00 | Flying Capacitor Circuit Voltage Out of Range |
| P1AFD1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range |
| P1AFF00 | Hybrid/EV Battery ECU Multiple Reset |
| P1B4011 | Hybrid/EV Battery Heater 1 Temperature Sensor Circuit Short to Ground |
| P1B4015 | Hybrid/EV Battery Heater 1 Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B4511 | Hybrid/EV Battery Heater 2 Temperature Sensor Circuit Short to Ground |
| P1B4515 | Hybrid/EV Battery Heater 2 Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B4A62 | Hybrid/EV Battery Heater Temperature Sensor Signal Compare Failure |
| P1B4B72 | Hybrid/EV Battery Heater Relay Actuator Stuck Open |
| P1B4B73 | Hybrid/EV Battery Heater Relay Actuator Stuck Closed |
| P1B5011 | Junction Block Positive Contactor Temperature Sensor Circuit Short to Ground |
| P1B5015 | Junction Block Positive Contactor Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B502A | Junction Block Positive Contactor Temperature Sensor Signal Stuck In Range |
| P1B5511 | Junction Block Negative Contactor Temperature Sensor Circuit Short to Ground |
| P1B5515 | Junction Block Negative Contactor Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B552A | Junction Block Negative Contactor Temperature Sensor Signal Stuck In Range |
| P1B5A62 | Junction Block Positive / Negative Temperature Sensor Signal Compare Failure |
| P1C8549 | High Voltage Power Resource Internal Electronic Failure |
| P1C9F11 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Ground |
| P1C9F15 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Auxiliary Battery or Open |
| P1C9F1C | Hybrid/EV Battery Current Sensor for Driving Control Voltage Out of Range |
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery |
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open |
| P1CC81E | Hybrid/EV Battery Stack 1 Voltage Difference Out of Range |
| P1CC91E | Hybrid/EV Battery Stack 2 Voltage Difference Out of Range |
| P1CCA1E | Hybrid/EV Battery Stack 3 Voltage Difference Out of Range |
| P1CCB1E | Hybrid/EV Battery Stack 4 Voltage Difference Out of Range |
| P1CE51E | Hybrid/EV Battery Stack 5 Voltage Difference Out of Range |
| P300000 | Hybrid/EV Battery Discharge Control Malfunction |
| P300016 | Hybrid/EV Battery Control System Circuit Voltage Below Threshold |
| P30004B | Hybrid/EV Battery Control System Over Temperature |
| P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range |
| P306562 | Hybrid/EV Battery Temperature Sensor "Group 1" Signal Compare Failure |
| P306A62 | Hybrid/EV Battery Temperature Sensor "Group 2" Signal Compare Failure |
| P306B62 | Hybrid/EV Battery Temperature Sensor "Group 3" Signal Compare Failure |
| P306F62 | Hybrid/EV Battery Temperature Sensor "Group 4" Signal Compare Failure |
| P30FF62 | Hybrid/EV Battery Temperature Sensor "Group 5" Signal Compare Failure |
| P310362 | Hybrid/EV Battery Air Temperature Sensor "A"/"B" Signal Compare Failure |
| P31AA17 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold |
| P31AB16 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold |
| P31B300 | Hybrid/EV Battery Voltage High |
| P31B400 | Extreme Hybrid/EV Battery Charging Current |
| P31B549 | Hybrid/EV Battery Internal Electronic Failure |
| P33DA1E | Hybrid/EV Battery Stack 1 Circuit Resistance Out of Range |
| P33DB1E | Hybrid/EV Battery Stack 2 Circuit Resistance Out of Range |
| P33DC1E | Hybrid/EV Battery Stack 3 Circuit Resistance Out of Range |
| P33DD1E | Hybrid/EV Battery Stack 4 Circuit Resistance Out of Range |
| P33DE1E | Hybrid/EV Battery Stack 5 Circuit Resistance Out of Range |
| P33E01B | Hybrid/EV Battery Stack 1 Circuit Resistance Above Threshold |
| P33E11B | Hybrid/EV Battery Stack 2 Circuit Resistance Above Threshold |
| P33E21B | Hybrid/EV Battery Stack 3 Circuit Resistance Above Threshold |
| P33E31B | Hybrid/EV Battery Stack 4 Circuit Resistance Above Threshold |
| P33E41B | Hybrid/EV Battery Stack 5 Circuit Resistance Above Threshold |
| P33E600 | Hybrid/EV Battery Stack 1 Capacity Decline |
| P33E700 | Hybrid/EV Battery Stack 2 Capacity Decline |
| P33E800 | Hybrid/EV Battery Stack 3 Capacity Decline |
| P33E900 | Hybrid/EV Battery Stack 4 Capacity Decline |
| P33EA00 | Hybrid/EV Battery Stack 5 Capacity Decline |
| P33EC16 | (Extreme) Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold |
| P33ED16 | (Extreme) Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold |
| P33EE16 | (Extreme) Hybrid/EV Battery Stack 3 Cell Circuit Voltage Below Threshold |
| P33EF16 | (Extreme) Hybrid/EV Battery Stack 4 Cell Circuit Voltage Below Threshold |
| P33F016 | (Extreme) Hybrid/EV Battery Stack 5 Cell Circuit Voltage Below Threshold |
| U010087 | Lost Communication with ECM/PCM "A" Missing Message |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U115087 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message |
HYBRID BATTERY SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [12/2018 - 05/2019]
| DTC Code | Description |
|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open |
| P060629 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message |
| P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060A87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message |
| P060B16 | Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold |
| P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure |
| P062F44 | Hybrid/EV Battery Energy Control Module EEPROM Data Memory Failure |
| P062F46 | Hybrid/EV Battery Energy Control Module EEPROM Calibration / Parameter Memory Failure |
| P0A1D94 | Hybrid/EV Powertrain Control Module Unexpected Operation |
| P0A8111 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground |
| P0A8115 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open |
| P0A8196 | Hybrid/EV Battery Cooling Fan 1 Component Internal Failure |
| P0A9563 | High Voltage Fuse Accumulated Load History |
| P0A9611 | Hybrid/EV Battery Cooling Fan 2 Circuit Short to Ground |
| P0A9615 | Hybrid/EV Battery Cooling Fan 2 Circuit Short to Auxiliary Battery or Open |
| P0A9696 | Hybrid/EV Battery Cooling Fan 2 Component Internal Failure |
| P0A9B11 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Ground |
| P0A9B15 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0A9B1C | Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range |
| P0A9B2A | Hybrid/EV Battery Temperature Sensor "A" Signal Stuck In Range |
| P0AA716 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Voltage Below Threshold |
| P0AA717 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Voltage Above Threshold |
| P0AAC11 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground |
| P0AAC15 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0AB111 | Hybrid/EV Battery Air Temperature Sensor "B" Circuit Short to Ground |
| P0AB115 | Hybrid/EV Battery Air Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open |
| P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground |
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range |
| P0AC511 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Ground |
| P0AC515 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open |
| P0AC51C | Hybrid/EV Battery Temperature Sensor "B" Voltage Out of Range |
| P0AC52A | Hybrid/EV Battery Temperature Sensor "B" Signal Stuck In Range |
| P0ACA11 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Ground |
| P0ACA15 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P0ACA1C | Hybrid/EV Battery Temperature Sensor "C" Voltage Out of Range |
| P0ACA2A | Hybrid/EV Battery Temperature Sensor "C" Signal Stuck In Range |
| P0AE811 | Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Ground |
| P0AE815 | Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Auxiliary Battery or Open |
| P0AE81C | Hybrid/EV Battery Temperature Sensor "D" Voltage Out of Range |
| P0AE82A | Hybrid/EV Battery Temperature Sensor "D" Signal Stuck In Range |
| P0B0E11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground |
| P0B0E15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open |
| P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure |
| P0BC211 | Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Ground |
| P0BC215 | Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Auxiliary Battery or Open |
| P0BC21C | Hybrid/EV Battery Temperature Sensor "E" Voltage Out of Range |
| P0BC22A | Hybrid/EV Battery Temperature Sensor "E" Signal Stuck In Range |
| P0C3000 | Hybrid/EV Battery State of Charge High |
| P0C3311 | Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Ground |
| P0C3315 | Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Auxiliary Battery or Open |
| P0C331C | Hybrid/EV Battery Temperature Sensor "F" Voltage Out of Range |
| P0C332A | Hybrid/EV Battery Temperature Sensor "F" Signal Stuck In Range |
| P0C7C11 | Hybrid/EV Battery Temperature Sensor "G" Circuit Short to Ground |
| P0C7C15 | Hybrid/EV Battery Temperature Sensor "G" Circuit Short to Auxiliary Battery or Open |
| P0C7C1C | Hybrid/EV Battery Temperature Sensor "G" Voltage Out of Range |
| P0C7C2A | Hybrid/EV Battery Temperature Sensor "G" Signal Stuck In Range |
| P0C8111 | Hybrid/EV Battery Temperature Sensor "H" Circuit Short to Ground |
| P0C8115 | Hybrid/EV Battery Temperature Sensor "H" Circuit Short to Auxiliary Battery or Open |
| P0C811C | Hybrid/EV Battery Temperature Sensor "H" Voltage Out of Range |
| P0C812A | Hybrid/EV Battery Temperature Sensor "H" Signal Stuck In Range |
| P0C8811 | Hybrid/EV Battery Temperature Sensor "I" Circuit Short to Ground |
| P0C8815 | Hybrid/EV Battery Temperature Sensor "I" Circuit Short to Auxiliary Battery or Open |
| P0C881C | Hybrid/EV Battery Temperature Sensor "I" Voltage Out of Range |
| P0C882A | Hybrid/EV Battery Temperature Sensor "I" Signal Stuck In Range |
| P0C8D11 | Hybrid/EV Battery Temperature Sensor "J" Circuit Short to Ground |
| P0C8D15 | Hybrid/EV Battery Temperature Sensor "J" Circuit Short to Auxiliary Battery or Open |
| P0C8D1C | Hybrid/EV Battery Temperature Sensor "J" Voltage Out of Range |
| P0C8D2A | Hybrid/EV Battery Temperature Sensor "J" Signal Stuck In Range |
| P0C9211 | Hybrid/EV Battery Temperature Sensor "K" Circuit Short to Ground |
| P0C9215 | Hybrid/EV Battery Temperature Sensor "K" Circuit Short to Auxiliary Battery or Open |
| P0C921C | Hybrid/EV Battery Temperature Sensor "K" Voltage Out of Range |
| P0C922A | Hybrid/EV Battery Temperature Sensor "K" Signal Stuck In Range |
| P0C9711 | Hybrid/EV Battery Temperature Sensor "L" Circuit Short to Ground |
| P0C9715 | Hybrid/EV Battery Temperature Sensor "L" Circuit Short to Auxiliary Battery or Open |
| P0C971C | Hybrid/EV Battery Temperature Sensor "L" Voltage Out of Range |
| P0C972A | Hybrid/EV Battery Temperature Sensor "L" Signal Stuck In Range |
| P0CA811 | Hybrid/EV Battery Temperature Sensor "M" Circuit Short to Ground |
| P0CA815 | Hybrid/EV Battery Temperature Sensor "M" Circuit Short to Auxiliary Battery or Open |
| P0CA81C | Hybrid/EV Battery Temperature Sensor "M" Voltage Out of Range |
| P0CA82A | Hybrid/EV Battery Temperature Sensor "M" Signal Stuck In Range |
| P0CAD11 | Hybrid/EV Battery Temperature Sensor "N" Circuit Short to Ground |
| P0CAD15 | Hybrid/EV Battery Temperature Sensor "N" Circuit Short to Auxiliary Battery or Open |
| P0CAD1C | Hybrid/EV Battery Temperature Sensor "N" Voltage Out of Range |
| P0CAD2A | Hybrid/EV Battery Temperature Sensor "N" Signal Stuck In Range |
| P0CB211 | Hybrid/EV Battery Temperature Sensor "O" Circuit Short to Ground |
| P0CB215 | Hybrid/EV Battery Temperature Sensor "O" Circuit Short to Auxiliary Battery or Open |
| P0CB21C | Hybrid/EV Battery Temperature Sensor "O" Voltage Out of Range |
| P0CB22A | Hybrid/EV Battery Temperature Sensor "O" Signal Stuck In Range |
| P0D0A11 | Hybrid/EV Battery Charging System Positive Contactor Control Circuit Short to Ground |
| P0D0A15 | Hybrid/EV Battery Charging System Positive Contactor Control Circuit Short to Auxiliary Battery or Open |
| P0D1111 | Hybrid/EV Battery Charging System Negative Contactor Control Circuit Short to Ground |
| P0D1115 | Hybrid/EV Battery Charging System Negative Contactor Control Circuit Short to Auxiliary Battery or Open |
| P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance |
| P0E6D11 | Hybrid/EV Battery Charging System Precharge Contactor Control Circuit Short to Ground |
| P0E6D15 | Hybrid/EV Battery Charging System Precharge Contactor Control Circuit Short to Auxiliary Battery or Open |
| P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range |
| P1A051C | Hybrid Battery Stack 3 Cell Voltage Detection Voltage Out of Range |
| P1A0A1C | Hybrid Battery Stack 4 Cell Voltage Detection Voltage Out of Range |
| P1A101C | Hybrid Battery Stack 5 Cell Voltage Detection Voltage Out of Range |
| P1A6017 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold |
| P1A6116 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold |
| P1A6317 | Hybrid/EV Battery Stack 3 Cell Circuit Voltage Above Threshold |
| P1A6416 | Hybrid/EV Battery Stack 3 Cell Circuit Voltage Below Threshold |
| P1A6617 | Hybrid/EV Battery Stack 4 Cell Circuit Voltage Above Threshold |
| P1A6716 | Hybrid/EV Battery Stack 4 Cell Circuit Voltage Below Threshold |
| P1A6917 | Hybrid/EV Battery Stack 5 Cell Circuit Voltage Above Threshold |
| P1A6A16 | Hybrid/EV Battery Stack 5 Cell Circuit Voltage Below Threshold |
| P1A8000 | Hybrid/EV Battery Stack 1 Delta SOC High |
| P1A8100 | Hybrid/EV Battery Stack 1 Delta SOC High (Extreme) |
| P1A8500 | Hybrid/EV Battery Stack 2 Delta SOC High |
| P1A8600 | Hybrid/EV Battery Stack 2 Delta SOC High (Extreme) |
| P1A8A00 | Hybrid/EV Battery Stack 3 Delta SOC High |
| P1A8B00 | Hybrid/EV Battery Stack 3 Delta SOC High (Extreme) |
| P1A9000 | Hybrid/EV Battery Stack 4 Delta SOC High |
| P1A9100 | Hybrid/EV Battery Stack 4 Delta SOC High (Extreme) |
| P1A9500 | Hybrid/EV Battery Stack 5 Delta SOC High |
| P1A9600 | Hybrid/EV Battery Stack 5 Delta SOC High (Extreme) |
| P1AC413 | Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open |
| P1AC49E | Hybrid/EV Battery Stack 1 Current Interrupt Device Stuck On |
| P1AC513 | Hybrid/EV Battery Stack 2 Current Interrupt Device Circuit Open |
| P1AC59E | Hybrid/EV Battery Stack 2 Current Interrupt Device Stuck On |
| P1AC613 | Hybrid/EV Battery Stack 3 Current Interrupt Device Circuit Open |
| P1AC69E | Hybrid/EV Battery Stack 3 Current Interrupt Device Stuck On |
| P1AC713 | Hybrid/EV Battery Stack 4 Current Interrupt Device Circuit Open |
| P1AC79E | Hybrid/EV Battery Stack 4 Current Interrupt Device Stuck On |
| P1AC813 | Hybrid/EV Battery Stack 5 Current Interrupt Device Circuit Open |
| P1AC89E | Hybrid/EV Battery Stack 5 Current Interrupt Device Stuck On |
| P1AFC00 | System Voltage (AM) Circuit Voltage Below Threshold |
| P1AFD00 | Flying Capacitor Circuit Voltage Out of Range |
| P1AFD1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range |
| P1AFF00 | Hybrid/EV Battery ECU Multiple Reset |
| P1B4011 | Hybrid/EV Battery Heater 1 Temperature Sensor Circuit Short to Ground |
| P1B4015 | Hybrid/EV Battery Heater 1 Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B4511 | Hybrid/EV Battery Heater 2 Temperature Sensor Circuit Short to Ground |
| P1B4515 | Hybrid/EV Battery Heater 2 Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B4A62 | Hybrid/EV Battery Heater Temperature Sensor Signal Compare Failure |
| P1B4B72 | Hybrid/EV Battery Heater Relay Actuator Stuck Open |
| P1B4B73 | Hybrid/EV Battery Heater Relay Actuator Stuck Closed |
| P1B5011 | Junction Block Positive Contactor Temperature Sensor Circuit Short to Ground |
| P1B5015 | Junction Block Positive Contactor Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B502A | Junction Block Positive Contactor Temperature Sensor Signal Stuck In Range |
| P1B5511 | Junction Block Negative Contactor Temperature Sensor Circuit Short to Ground |
| P1B5515 | Junction Block Negative Contactor Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B552A | Junction Block Negative Contactor Temperature Sensor Signal Stuck In Range |
| P1B5A62 | Junction Block Positive / Negative Temperature Sensor Signal Compare Failure |
| P1C8549 | High Voltage Power Resource Internal Electronic Failure |
| P1C9F11 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Ground |
| P1C9F15 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Auxiliary Battery or Open |
| P1C9F1C | Hybrid/EV Battery Current Sensor for Driving Control Voltage Out of Range |
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery |
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open |
| P1CC81E | Hybrid/EV Battery Stack 1 Voltage Difference Out of Range |
| P1CC91E | Hybrid/EV Battery Stack 2 Voltage Difference Out of Range |
| P1CCA1E | Hybrid/EV Battery Stack 3 Voltage Difference Out of Range |
| P1CCB1E | Hybrid/EV Battery Stack 4 Voltage Difference Out of Range |
| P1CE51E | Hybrid/EV Battery Stack 5 Voltage Difference Out of Range |
| P300000 | Hybrid/EV Battery Discharge Control Malfunction |
| P300016 | Hybrid/EV Battery Control System Circuit Voltage Below Threshold |
| P30004B | Hybrid/EV Battery Control System Over Temperature |
| P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range |
| P306562 | Hybrid/EV Battery Temperature Sensor "Group 1" Signal Compare Failure |
| P306A62 | Hybrid/EV Battery Temperature Sensor "Group 2" Signal Compare Failure |
| P306B62 | Hybrid/EV Battery Temperature Sensor "Group 3" Signal Compare Failure |
| P306F62 | Hybrid/EV Battery Temperature Sensor "Group 4" Signal Compare Failure |
| P30FF62 | Hybrid/EV Battery Temperature Sensor "Group 5" Signal Compare Failure |
| P310362 | Hybrid/EV Battery Air Temperature Sensor "A"/"B" Signal Compare Failure |
| P31AA17 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold |
| P31AB16 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold |
| P31B300 | Hybrid/EV Battery Voltage High |
| P31B400 | Extreme Hybrid/EV Battery Charging Current |
| P31B549 | Hybrid/EV Battery Internal Electronic Failure |
| P33DA1E | Hybrid/EV Battery Stack 1 Circuit Resistance Out of Range |
| P33DB1E | Hybrid/EV Battery Stack 2 Circuit Resistance Out of Range |
| P33DC1E | Hybrid/EV Battery Stack 3 Circuit Resistance Out of Range |
| P33DD1E | Hybrid/EV Battery Stack 4 Circuit Resistance Out of Range |
| P33DE1E | Hybrid/EV Battery Stack 5 Circuit Resistance Out of Range |
| P33E01B | Hybrid/EV Battery Stack 1 Circuit Resistance Above Threshold |
| P33E11B | Hybrid/EV Battery Stack 2 Circuit Resistance Above Threshold |
| P33E21B | Hybrid/EV Battery Stack 3 Circuit Resistance Above Threshold |
| P33E31B | Hybrid/EV Battery Stack 4 Circuit Resistance Above Threshold |
| P33E41B | Hybrid/EV Battery Stack 5 Circuit Resistance Above Threshold |
| P33E600 | Hybrid/EV Battery Stack 1 Capacity Decline |
| P33E700 | Hybrid/EV Battery Stack 2 Capacity Decline |
| P33E800 | Hybrid/EV Battery Stack 3 Capacity Decline |
| P33E900 | Hybrid/EV Battery Stack 4 Capacity Decline |
| P33EA00 | Hybrid/EV Battery Stack 5 Capacity Decline |
| P33EC16 | (Extreme) Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold |
| P33ED16 | (Extreme) Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold |
| P33EE16 | (Extreme) Hybrid/EV Battery Stack 3 Cell Circuit Voltage Below Threshold |
| P33EF16 | (Extreme) Hybrid/EV Battery Stack 4 Cell Circuit Voltage Below Threshold |
| P33F016 | (Extreme) Hybrid/EV Battery Stack 5 Cell Circuit Voltage Below Threshold |
| U010087 | Lost Communication with ECM/PCM "A" Missing Message |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U115087 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message |
HYBRID BATTERY SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION [05/2019 - ]
| DTC Code | Description |
|---|---|
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open |
| P060629 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Signal Invalid |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message |
| P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060A87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message |
| P060B16 | Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold |
| P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure |
| P062F44 | Hybrid/EV Battery Energy Control Module EEPROM Data Memory Failure |
| P062F46 | Hybrid/EV Battery Energy Control Module EEPROM Calibration / Parameter Memory Failure |
| P0A1D94 | Hybrid/EV Powertrain Control Module Unexpected Operation |
| P0A8100 | Hybrid/EV Battery Cooling Fan 1 Control Circuit High |
| P0A8111 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground |
| P0A8115 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open |
| P0A814B | Hybrid/EV Battery Cooling Fan 1 Over Temperature |
| P0A8196 | Hybrid/EV Battery Cooling Fan 1 Component Internal Failure |
| P0A8198 | Hybrid/EV Battery Cooling Fan 1 Component or System Over Temperature |
| P0A9563 | High Voltage Fuse Accumulated Load History |
| P0A9600 | Hybrid/EV Battery Cooling Fan 2 Control Circuit High |
| P0A9611 | Hybrid/EV Battery Cooling Fan 2 Circuit Short to Ground |
| P0A9615 | Hybrid/EV Battery Cooling Fan 2 Circuit Short to Auxiliary Battery or Open |
| P0A964B | Hybrid/EV Battery Cooling Fan 2 Over Temperature |
| P0A9696 | Hybrid/EV Battery Cooling Fan 2 Component Internal Failure |
| P0A9698 | Hybrid/EV Battery Cooling Fan 2 Component or System Over Temperature |
| P0A9B11 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Ground |
| P0A9B15 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0A9B1C | Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range |
| P0A9B2A | Hybrid/EV Battery Temperature Sensor "A" Signal Stuck In Range |
| P0AA716 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Voltage Below Threshold |
| P0AA717 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Voltage Above Threshold |
| P0AAC11 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground |
| P0AAC15 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0AB111 | Hybrid/EV Battery Air Temperature Sensor "B" Circuit Short to Ground |
| P0AB115 | Hybrid/EV Battery Air Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open |
| P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground |
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open |
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range |
| P0AC511 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Ground |
| P0AC515 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open |
| P0AC51C | Hybrid/EV Battery Temperature Sensor "B" Voltage Out of Range |
| P0AC52A | Hybrid/EV Battery Temperature Sensor "B" Signal Stuck In Range |
| P0ACA11 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Ground |
| P0ACA15 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
| P0ACA1C | Hybrid/EV Battery Temperature Sensor "C" Voltage Out of Range |
| P0ACA2A | Hybrid/EV Battery Temperature Sensor "C" Signal Stuck In Range |
| P0AE811 | Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Ground |
| P0AE815 | Hybrid/EV Battery Temperature Sensor "D" Circuit Short to Auxiliary Battery or Open |
| P0AE81C | Hybrid/EV Battery Temperature Sensor "D" Voltage Out of Range |
| P0AE82A | Hybrid/EV Battery Temperature Sensor "D" Signal Stuck In Range |
| P0B0E11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground |
| P0B0E15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open |
| P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure |
| P0BC211 | Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Ground |
| P0BC215 | Hybrid/EV Battery Temperature Sensor "E" Circuit Short to Auxiliary Battery or Open |
| P0BC21C | Hybrid/EV Battery Temperature Sensor "E" Voltage Out of Range |
| P0BC22A | Hybrid/EV Battery Temperature Sensor "E" Signal Stuck In Range |
| P0C3000 | Hybrid/EV Battery State of Charge High |
| P0C3311 | Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Ground |
| P0C3315 | Hybrid/EV Battery Temperature Sensor "F" Circuit Short to Auxiliary Battery or Open |
| P0C331C | Hybrid/EV Battery Temperature Sensor "F" Voltage Out of Range |
| P0C332A | Hybrid/EV Battery Temperature Sensor "F" Signal Stuck In Range |
| P0C7C11 | Hybrid/EV Battery Temperature Sensor "G" Circuit Short to Ground |
| P0C7C15 | Hybrid/EV Battery Temperature Sensor "G" Circuit Short to Auxiliary Battery or Open |
| P0C7C1C | Hybrid/EV Battery Temperature Sensor "G" Voltage Out of Range |
| P0C7C2A | Hybrid/EV Battery Temperature Sensor "G" Signal Stuck In Range |
| P0C8111 | Hybrid/EV Battery Temperature Sensor "H" Circuit Short to Ground |
| P0C8115 | Hybrid/EV Battery Temperature Sensor "H" Circuit Short to Auxiliary Battery or Open |
| P0C811C | Hybrid/EV Battery Temperature Sensor "H" Voltage Out of Range |
| P0C812A | Hybrid/EV Battery Temperature Sensor "H" Signal Stuck In Range |
| P0C8811 | Hybrid/EV Battery Temperature Sensor "I" Circuit Short to Ground |
| P0C8815 | Hybrid/EV Battery Temperature Sensor "I" Circuit Short to Auxiliary Battery or Open |
| P0C881C | Hybrid/EV Battery Temperature Sensor "I" Voltage Out of Range |
| P0C882A | Hybrid/EV Battery Temperature Sensor "I" Signal Stuck In Range |
| P0C8D11 | Hybrid/EV Battery Temperature Sensor "J" Circuit Short to Ground |
| P0C8D15 | Hybrid/EV Battery Temperature Sensor "J" Circuit Short to Auxiliary Battery or Open |
| P0C8D1C | Hybrid/EV Battery Temperature Sensor "J" Voltage Out of Range |
| P0C8D2A | Hybrid/EV Battery Temperature Sensor "J" Signal Stuck In Range |
| P0C9211 | Hybrid/EV Battery Temperature Sensor "K" Circuit Short to Ground |
| P0C9215 | Hybrid/EV Battery Temperature Sensor "K" Circuit Short to Auxiliary Battery or Open |
| P0C921C | Hybrid/EV Battery Temperature Sensor "K" Voltage Out of Range |
| P0C922A | Hybrid/EV Battery Temperature Sensor "K" Signal Stuck In Range |
| P0C9711 | Hybrid/EV Battery Temperature Sensor "L" Circuit Short to Ground |
| P0C9715 | Hybrid/EV Battery Temperature Sensor "L" Circuit Short to Auxiliary Battery or Open |
| P0C971C | Hybrid/EV Battery Temperature Sensor "L" Voltage Out of Range |
| P0C972A | Hybrid/EV Battery Temperature Sensor "L" Signal Stuck In Range |
| P0CA811 | Hybrid/EV Battery Temperature Sensor "M" Circuit Short to Ground |
| P0CA815 | Hybrid/EV Battery Temperature Sensor "M" Circuit Short to Auxiliary Battery or Open |
| P0CA81C | Hybrid/EV Battery Temperature Sensor "M" Voltage Out of Range |
| P0CA82A | Hybrid/EV Battery Temperature Sensor "M" Signal Stuck In Range |
| P0CAD11 | Hybrid/EV Battery Temperature Sensor "N" Circuit Short to Ground |
| P0CAD15 | Hybrid/EV Battery Temperature Sensor "N" Circuit Short to Auxiliary Battery or Open |
| P0CAD1C | Hybrid/EV Battery Temperature Sensor "N" Voltage Out of Range |
| P0CAD2A | Hybrid/EV Battery Temperature Sensor "N" Signal Stuck In Range |
| P0CB211 | Hybrid/EV Battery Temperature Sensor "O" Circuit Short to Ground |
| P0CB215 | Hybrid/EV Battery Temperature Sensor "O" Circuit Short to Auxiliary Battery or Open |
| P0CB21C | Hybrid/EV Battery Temperature Sensor "O" Voltage Out of Range |
| P0CB22A | Hybrid/EV Battery Temperature Sensor "O" Signal Stuck In Range |
| P0D0A11 | Hybrid/EV Battery Charging System Positive Contactor Control Circuit Short to Ground |
| P0D0A15 | Hybrid/EV Battery Charging System Positive Contactor Control Circuit Short to Auxiliary Battery or Open |
| P0D1111 | Hybrid/EV Battery Charging System Negative Contactor Control Circuit Short to Ground |
| P0D1115 | Hybrid/EV Battery Charging System Negative Contactor Control Circuit Short to Auxiliary Battery or Open |
| P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance |
| P0E6D11 | Hybrid/EV Battery Charging System Precharge Contactor Control Circuit Short to Ground |
| P0E6D15 | Hybrid/EV Battery Charging System Precharge Contactor Control Circuit Short to Auxiliary Battery or Open |
| P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range |
| P1A051C | Hybrid Battery Stack 3 Cell Voltage Detection Voltage Out of Range |
| P1A0A1C | Hybrid Battery Stack 4 Cell Voltage Detection Voltage Out of Range |
| P1A101C | Hybrid Battery Stack 5 Cell Voltage Detection Voltage Out of Range |
| P1A6017 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Above Threshold |
| P1A6116 | Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold |
| P1A6317 | Hybrid/EV Battery Stack 3 Cell Circuit Voltage Above Threshold |
| P1A6416 | Hybrid/EV Battery Stack 3 Cell Circuit Voltage Below Threshold |
| P1A6617 | Hybrid/EV Battery Stack 4 Cell Circuit Voltage Above Threshold |
| P1A6716 | Hybrid/EV Battery Stack 4 Cell Circuit Voltage Below Threshold |
| P1A6917 | Hybrid/EV Battery Stack 5 Cell Circuit Voltage Above Threshold |
| P1A6A16 | Hybrid/EV Battery Stack 5 Cell Circuit Voltage Below Threshold |
| P1A8000 | Hybrid/EV Battery Stack 1 Delta SOC High |
| P1A8100 | Hybrid/EV Battery Stack 1 Delta SOC High (Extreme) |
| P1A8500 | Hybrid/EV Battery Stack 2 Delta SOC High |
| P1A8600 | Hybrid/EV Battery Stack 2 Delta SOC High (Extreme) |
| P1A8A00 | Hybrid/EV Battery Stack 3 Delta SOC High |
| P1A8B00 | Hybrid/EV Battery Stack 3 Delta SOC High (Extreme) |
| P1A9000 | Hybrid/EV Battery Stack 4 Delta SOC High |
| P1A9100 | Hybrid/EV Battery Stack 4 Delta SOC High (Extreme) |
| P1A9500 | Hybrid/EV Battery Stack 5 Delta SOC High |
| P1A9600 | Hybrid/EV Battery Stack 5 Delta SOC High (Extreme) |
| P1AC413 | Hybrid/EV Battery Stack 1 Current Interrupt Device Circuit Open |
| P1AC49E | Hybrid/EV Battery Stack 1 Current Interrupt Device Stuck On |
| P1AC513 | Hybrid/EV Battery Stack 2 Current Interrupt Device Circuit Open |
| P1AC59E | Hybrid/EV Battery Stack 2 Current Interrupt Device Stuck On |
| P1AC613 | Hybrid/EV Battery Stack 3 Current Interrupt Device Circuit Open |
| P1AC69E | Hybrid/EV Battery Stack 3 Current Interrupt Device Stuck On |
| P1AC713 | Hybrid/EV Battery Stack 4 Current Interrupt Device Circuit Open |
| P1AC79E | Hybrid/EV Battery Stack 4 Current Interrupt Device Stuck On |
| P1AC813 | Hybrid/EV Battery Stack 5 Current Interrupt Device Circuit Open |
| P1AC89E | Hybrid/EV Battery Stack 5 Current Interrupt Device Stuck On |
| P1AFC00 | System Voltage (AM) Circuit Voltage Below Threshold |
| P1AFD00 | Flying Capacitor Circuit Voltage Out of Range |
| P1AFD1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range |
| P1AFF00 | Hybrid/EV Battery ECU Multiple Reset |
| P1B4011 | Hybrid/EV Battery Heater 1 Temperature Sensor Circuit Short to Ground |
| P1B4015 | Hybrid/EV Battery Heater 1 Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B4511 | Hybrid/EV Battery Heater 2 Temperature Sensor Circuit Short to Ground |
| P1B4515 | Hybrid/EV Battery Heater 2 Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B4A62 | Hybrid/EV Battery Heater Temperature Sensor Signal Compare Failure |
| P1B4B72 | Hybrid/EV Battery Heater Relay Actuator Stuck Open |
| P1B4B73 | Hybrid/EV Battery Heater Relay Actuator Stuck Closed |
| P1B5011 | Junction Block Positive Contactor Temperature Sensor Circuit Short to Ground |
| P1B5015 | Junction Block Positive Contactor Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B502A | Junction Block Positive Contactor Temperature Sensor Signal Stuck In Range |
| P1B5511 | Junction Block Negative Contactor Temperature Sensor Circuit Short to Ground |
| P1B5515 | Junction Block Negative Contactor Temperature Sensor Circuit Short to Auxiliary Battery or Open |
| P1B552A | Junction Block Negative Contactor Temperature Sensor Signal Stuck In Range |
| P1B5A62 | Junction Block Positive / Negative Temperature Sensor Signal Compare Failure |
| P1C8549 | High Voltage Power Resource Internal Electronic Failure |
| P1C9F11 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Ground |
| P1C9F15 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Auxiliary Battery or Open |
| P1C9F1C | Hybrid/EV Battery Current Sensor for Driving Control Voltage Out of Range |
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery |
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open |
| P1CC81E | Hybrid/EV Battery Stack 1 Voltage Difference Out of Range |
| P1CC91E | Hybrid/EV Battery Stack 2 Voltage Difference Out of Range |
| P1CCA1E | Hybrid/EV Battery Stack 3 Voltage Difference Out of Range |
| P1CCB1E | Hybrid/EV Battery Stack 4 Voltage Difference Out of Range |
| P1CE51E | Hybrid/EV Battery Stack 5 Voltage Difference Out of Range |
| P300000 | Hybrid/EV Battery Discharge Control Malfunction |
| P300016 | Hybrid/EV Battery Control System Circuit Voltage Below Threshold |
| P30004B | Hybrid/EV Battery Control System Over Temperature |
| P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range |
| P306562 | Hybrid/EV Battery Temperature Sensor "Group 1" Signal Compare Failure |
| P306A62 | Hybrid/EV Battery Temperature Sensor "Group 2" Signal Compare Failure |
| P306B62 | Hybrid/EV Battery Temperature Sensor "Group 3" Signal Compare Failure |
| P306F62 | Hybrid/EV Battery Temperature Sensor "Group 4" Signal Compare Failure |
| P30FF62 | Hybrid/EV Battery Temperature Sensor "Group 5" Signal Compare Failure |
| P310362 | Hybrid/EV Battery Air Temperature Sensor "A"/"B" Signal Compare Failure |
| P31AA17 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Above Threshold |
| P31AB16 | Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold |
| P31B300 | Hybrid/EV Battery Voltage High |
| P31B400 | Extreme Hybrid/EV Battery Charging Current |
| P31B549 | Hybrid/EV Battery Internal Electronic Failure |
| P33DA1E | Hybrid/EV Battery Stack 1 Circuit Resistance Out of Range |
| P33DB1E | Hybrid/EV Battery Stack 2 Circuit Resistance Out of Range |
| P33DC1E | Hybrid/EV Battery Stack 3 Circuit Resistance Out of Range |
| P33DD1E | Hybrid/EV Battery Stack 4 Circuit Resistance Out of Range |
| P33DE1E | Hybrid/EV Battery Stack 5 Circuit Resistance Out of Range |
| P33E01B | Hybrid/EV Battery Stack 1 Circuit Resistance Above Threshold |
| P33E11B | Hybrid/EV Battery Stack 2 Circuit Resistance Above Threshold |
| P33E21B | Hybrid/EV Battery Stack 3 Circuit Resistance Above Threshold |
| P33E31B | Hybrid/EV Battery Stack 4 Circuit Resistance Above Threshold |
| P33E41B | Hybrid/EV Battery Stack 5 Circuit Resistance Above Threshold |
| P33E600 | Hybrid/EV Battery Stack 1 Capacity Decline |
| P33E700 | Hybrid/EV Battery Stack 2 Capacity Decline |
| P33E800 | Hybrid/EV Battery Stack 3 Capacity Decline |
| P33E900 | Hybrid/EV Battery Stack 4 Capacity Decline |
| P33EA00 | Hybrid/EV Battery Stack 5 Capacity Decline |
| P33EC16 | (Extreme) Hybrid/EV Battery Stack 1 Cell Circuit Voltage Below Threshold |
| P33ED16 | (Extreme) Hybrid/EV Battery Stack 2 Cell Circuit Voltage Below Threshold |
| P33EE16 | (Extreme) Hybrid/EV Battery Stack 3 Cell Circuit Voltage Below Threshold |
| P33EF16 | (Extreme) Hybrid/EV Battery Stack 4 Cell Circuit Voltage Below Threshold |
| P33F016 | (Extreme) Hybrid/EV Battery Stack 5 Cell Circuit Voltage Below Threshold |
| U010087 | Lost Communication with ECM/PCM "A" Missing Message |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message |
| U115087 | Lost Communication with Hybrid Powertrain Control Module (Hybrid/EV Battery Local Bus) Missing Message |