Service Data

Item Specification
Battery electrolyte specific gravity 1.22 to 1.29 [20 °C (68 °F)]
Battery load test current 55D23L (60 A*h/20HR): 180 A
GR35 (60 A*h/20HR): 180 A
N-55 (50 A*h/20HR): 130 A
Battery parasitic draw (When the ignition is off, all doors and the bonnet are closed.) 40 to 65 mA
Generator standard voltage [IG-ON] Terminal 1A: B+
Terminal 2A: Approx. 1 V or less
Terminal 2B: Approx. 0 V
Generator standard voltage [Idle, 20 °C (68 °F)] Terminal 1A: 13 to 15 V
Terminal 2A: Approx. 3 to 8 V
Terminal 2B: Turn the electrical loads (such as headlights, blower motor, rear window defogger, brake lights) on and verify that the voltage reading increases.
Generator generated current minimum value 70% of the nominal output current (nominal output current: 100 A) [Ambient temp. 20 °C (68 °F), voltage 13.0 to 15.0 V, both engine and generator are hot]
Generator rotor resistance (between slip rings) [20 °C (68 °F)] 1.9 to 2.2 ohms
Generator brush length Standard: 22.5 mm (0.886 in)
Minimum: 5.0 mm (0.20 in)
Generator brush spring force Standard: 4.1 to 5.3 N (0.42 to 0.54 kgf, 1.0 to 1.1 lbf)
Minimum: 1.7 N (0.17 kgf, 0.38 lbf)