LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2018 >> 86 Base, Automatic Trans >> Repair and Diagnosis (Single Page) >> Engine Mechanical >> Starter >> Engine Starting System (Service Specifications) >> Fa20 Starting >> Service Data [06/2016 - 03/2017] >> Service Data [06/2016 - 03/2017]
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data [06/2016 - 03/2017]

Starter assembly Standard current Below 90 A at 11.5 V
Starter armature assembly Standard runout for Manual Transmission 0.05 mm (0.002 in.)
for Automatic Transmission 0.02 mm (0.0008 in.)
Maximum runout for Manual Transmission 0.10 mm (0.004 in.)
for Automatic Transmission 0.05 mm (0.002 in.)
Standard depth
Segment - Mold
for Manual Transmission 0.50 mm (0.020 in.)
for Automatic Transmission 0.7 mm (0.0276 in.)
Minimum depth
Segment - Mold
for Automatic Transmission 0.20 mm (0.0079 in.)
Standard resistance Segment - Segment
for Automatic Transmission
Below 1 Ω
Commutator - Armature coil core
for Automatic Transmission
10 kΩ or higher
Standard diameter for Automatic Transmission 29 mm (1.1417 in.)
Minimum diameter for Automatic Transmission 28 mm (1.1024 in.)
Brush length Standard length for Manual Transmission 12.3 mm (0.484 in.)
for Automatic Transmission 14.4 mm (0.5669 in.)
Minimum length for Manual Transmission 7.0 mm (0.276 in.)
for Automatic Transmission 9.0 mm (0.3543 in.)
Standard brush spring force for Manual Transmission 15.9 to 19.5 N (1.6 to 2.0 kgf, 3.6 to 4.4 lbf)
Minimum brush spring force for Manual Transmission 2.5 N (0.3 kgf, 0.6 lbf)
Standard resistance
for Automatic Transmission
A - B
A - C
B - D
C - D
10 kΩ or higher
A - D
B - C
Below 1 Ω
Starter magnetic switch assembly Standard resistance
Terminal 50 - Terminal C
for Manual Transmission Below 1 Ω
for Automatic Transmission Below 1 Ω
Standard resistance
Terminal 50 - Switch body
for Manual Transmission Below 1 Ω
for Automatic Transmission Below 2 Ω
Standard resistance
Terminal 30 - Terminal C
for Manual Transmission 1 MΩ or higher
Ignition switch assembly Standard resistance
All combinations of all terminals
LOCK 10 kΩ or higher
Standard resistance
2 (AM1) - 3 (ACC)
ACC Below 1 Ω
Standard resistance
2 (AM1) - 3 (ACC) - 4 (IG1)
6 (IG2) - 7 (AM2)
ON Below 1 Ω
Standard resistance
1 (ST1) - 2 (AM1) - 4 (IG1)
6 (IG2) - 7 (AM2) - 8 (ST2)
START Below 1 Ω
Starter relay Specified condition 1 - 2
(Battery voltage not applied to terminals 1 and 2)
(Measured temperature : 20 °C (68 °F))
144 to 176 Ω
3 - 5
(Battery voltage is applied between terminals 1 and 2)
Below 1 Ω
3 - 5
(Battery voltage is not applied between terminals 1 and 2)
10 kΩ or higher
Inhibitor relay Specified condition 1 - 2
(Battery voltage not applied to terminals 1 and 2)
(Measured temperature : 20 °C (68 °F))
93.8 to 136.4 Ω
3 - 5
(Battery voltage is applied between terminals 1 and 2)
Below 1 Ω
3 - 5
(Battery voltage is not applied between terminals 1 and 2)
10 kΩ or higher