Service Data [06/2016 - 03/2017]
| Starter assembly | Standard current | Below 90 A at 11.5 V | |
| Starter armature assembly | Standard runout | for Manual Transmission | 0.05 mm (0.002 in.) |
| for Automatic Transmission | 0.02 mm (0.0008 in.) | ||
| Maximum runout | for Manual Transmission | 0.10 mm (0.004 in.) | |
| for Automatic Transmission | 0.05 mm (0.002 in.) | ||
| Standard depth Segment - Mold |
for Manual Transmission | 0.50 mm (0.020 in.) | |
| for Automatic Transmission | 0.7 mm (0.0276 in.) | ||
| Minimum depth Segment - Mold |
for Automatic Transmission | 0.20 mm (0.0079 in.) | |
| Standard resistance | Segment - Segment for Automatic Transmission |
Below 1 Ω | |
| Commutator - Armature coil core for Automatic Transmission |
10 kΩ or higher | ||
| Standard diameter | for Automatic Transmission | 29 mm (1.1417 in.) | |
| Minimum diameter | for Automatic Transmission | 28 mm (1.1024 in.) | |
| Brush length | Standard length | for Manual Transmission | 12.3 mm (0.484 in.) |
| for Automatic Transmission | 14.4 mm (0.5669 in.) | ||
| Minimum length | for Manual Transmission | 7.0 mm (0.276 in.) | |
| for Automatic Transmission | 9.0 mm (0.3543 in.) | ||
| Standard brush spring force | for Manual Transmission | 15.9 to 19.5 N (1.6 to 2.0 kgf, 3.6 to 4.4 lbf) | |
| Minimum brush spring force | for Manual Transmission | 2.5 N (0.3 kgf, 0.6 lbf) | |
| Standard resistance for Automatic Transmission |
A - B A - C B - D C - D |
10 kΩ or higher | |
| A - D B - C |
Below 1 Ω | ||
| Starter magnetic switch assembly | Standard resistance Terminal 50 - Terminal C |
for Manual Transmission | Below 1 Ω |
| for Automatic Transmission | Below 1 Ω | ||
| Standard resistance Terminal 50 - Switch body |
for Manual Transmission | Below 1 Ω | |
| for Automatic Transmission | Below 2 Ω | ||
| Standard resistance Terminal 30 - Terminal C |
for Manual Transmission | 1 MΩ or higher | |
| Ignition switch assembly | Standard resistance All combinations of all terminals |
LOCK | 10 kΩ or higher |
| Standard resistance 2 (AM1) - 3 (ACC) |
ACC | Below 1 Ω | |
| Standard resistance 2 (AM1) - 3 (ACC) - 4 (IG1) 6 (IG2) - 7 (AM2) |
ON | Below 1 Ω | |
| Standard resistance 1 (ST1) - 2 (AM1) - 4 (IG1) 6 (IG2) - 7 (AM2) - 8 (ST2) |
START | Below 1 Ω | |
| Starter relay | Specified condition | 1 - 2 (Battery voltage not applied to terminals 1 and 2) (Measured temperature : 20 °C (68 °F)) |
144 to 176 Ω |
| 3 - 5 (Battery voltage is applied between terminals 1 and 2) |
Below 1 Ω | ||
| 3 - 5 (Battery voltage is not applied between terminals 1 and 2) |
10 kΩ or higher | ||
| Inhibitor relay | Specified condition | 1 - 2 (Battery voltage not applied to terminals 1 and 2) (Measured temperature : 20 °C (68 °F)) |
93.8 to 136.4 Ω |
| 3 - 5 (Battery voltage is applied between terminals 1 and 2) |
Below 1 Ω | ||
| 3 - 5 (Battery voltage is not applied between terminals 1 and 2) |