Power Windows do not Operate Using All Window Switch [08/2013 - ]: Procedure
- CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the H5 power window regulator master switch assembly connector.
- Measure the voltage and resistance according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition H5-6 (B) - Body ground Ignition switch ON 11 to 14 V Standard Resistance
Tester Connection Condition Specified Condition H5-1 (E) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 2
- REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
- Replace the power window regulator master switch assembly.
Refer to REMOVAL [08/2013 - ]
Result
Proceed to NEXT
Result: 1
NEXT
See step 3
- Replace the power window regulator master switch assembly.
- CHECK POWER WINDOW CONTROL SYSTEM
- Check the operation of the power windows by using the power window regulator master switch assembly, power window regulator switch assembly and rear power window regulator switch assemblies (for LH door or RH door).
Refer to OPERATION CHECK [08/2013 - 08/2016] Refer to OPERATION CHECK [08/2016 - ]
OK
All power windows operate normally.
Result
Proceed to OK NG
Result: 1
OK
END (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY WAS DEFECTIVE)
Result: 2
NG
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU). Refer to REMOVAL [08/2013 - ]
- Check the operation of the power windows by using the power window regulator master switch assembly, power window regulator switch assembly and rear power window regulator switch assemblies (for LH door or RH door).