Height Control Sensor
HEIGHT CONTROL SENSOR
| Connector Condition | Tester Connection | Condition | Specified Condition | |
|---|---|---|---|---|
| Component without harness connected | 1 (SHG) - 2 (SHRR) | Link moves upward from standard position to bound side (Height low) | From 38.8° to bound side link stop position | Approx. 0.5 V |
| 38.8° (Full Bound) | Approx. 0.7 V | |||
| Standard position | - | Approx. 2.25 V | ||
| Link moves downward from standard position to rebound side (Height high) | Horizontal Position | Approx. 2.47 V | ||
| 64.4° (Full Rebound) | Approx. 4.5 V | |||
| From 64.4° to rebound side link stop position | Approx. 4.5 V | |||