Typical Enabling Conditions
U0110 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C14C8: Brake system voltage circuit high U0293 (Case 1): Lost communication with HV (C-Bus) U0293 (Case 2): Lost communication with HV (C1-bus) |
| All of the following conditions are met | A and B |
| A. VM1 voltage | Higher than 7.3 V, and less than 23.2 V |
| B. Following condition is met | 3 seconds or more |
| IG2 voltage | less than 9.5 V |
U0129 AND U117D
| Monitor runs whenever the following DTCs are not stored | C123E: Brake system voltage input open circuit C137C: Brake system voltage input out of range low C137D: Brake system voltage input out of range high C14C7 (Case 1 and 2): Brake system voltage circuit low C14C8: Brake system voltage circuit high |
| IG1 | On |
U0293 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C137C (Case 5 and 6): Brake system voltage input out of range low C137D: Brake system voltage input out of range high C14C8: Brake system voltage circuit high |
| Both of the following conditions are met | A and B |
| A. VM1 voltage | Higher than 7.3 V, and less than 23.2 V |
| B. Following condition is met | 3 seconds or more |
| IG2 voltage | Higher than 9.5 V |
U1150 (CASE 2)
| Monitor runs whenever the following DTCs are not stored | C137C (Case 5 and 6): Brake system voltage input out of range low C137D: Brake system voltage input out of range high C14C8: Brake system voltage circuit high U0293 (Case 1): Lost communication with HV (C-Bus) U0293 (Case 2): Lost communication with HV (C1-Bus) |
| Both of the following conditions are met | A and B |
| A. VM1 voltage | Higher than 7.3 V, and less than 23.2 V |
| B. Following condition is met | 3 seconds or more |
| IG2 voltage | Higher than 9.5 V |