DTC P0443-13: Evaporative Emission System Purge Control Valve "A" Circuit Open [11/2018 - 08/2020]: Procedure
- PERFORM ACTIVE TEST USING TECHSTREAM (ACTIVATE THE EVAP PURGE VSV)
- Disconnect the fuel vapor feed hose assembly (canister side) of the purge VSV.
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Put the engine in Inspection Mode (Maintenance Mode).
Powertrain > Hybrid Control > Utility
Tester Display Inspection Mode - Start the engine.
- Enter the following menus: Powertrain / Engine / Active Test / Activate the EVAP Purge VSV.
Powertrain > Engine > Active Test
Tester Display Activate the EVAP Purge VSV - When the purge VSV is operated using the Techstream, check whether the port of the purge VSV applies suction your finger.
OK
Techstream Operation Specified Condition ON Purge VSV port applies suction to finger OFF Purge VSV port applies no suction to finger HINT:
Jiggle the wire harness and connector to increase the likelihood of detecting malfunctions that do not always occur.
Result
Proceed to OK NG
Result:
OK
CHECK FOR INTERMITTENT PROBLEMS. Refer to CHECK FOR INTERMITTENT PROBLEMS [11/2018 - 08/2020]
Result:
NG
See step 2
- INSPECT PURGE VSV
- Inspect the purge VSV.
Refer to INSPECTION [11/2018 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE PURGE VSV. Refer to REMOVAL [11/2018 - ]
Result:
OK
See step 3
- Inspect the purge VSV.
- CHECK TERMINAL VOLTAGE (POWER SOURCE OF PURGE VSV)
*a Front view of wire harness connector
(to Purge VSV)- Disconnect the purge VSV connector.
- Turn the power switch on (IG).
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition C19-1 - Body ground Power switch on (IG) 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (EFI-MAIN NO. 1 RELAY - PURGE VSV)
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (PURGE VSV - ECM)
- Disconnect the purge VSV connector.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition C19-2 - C45-66 (PRG) Always Below 1 Ω C19-2 or C45-66 (PRG) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE ECM. Refer to REMOVAL [11/2018 - 02/2019] , or refer to REMOVAL [02/2019 - 08/2020]
Result:
NG