Installation [11/2018 - 08/2020]: Procedure
- INSTALL MASS AIR FLOW METER SUB-ASSEMBLY
HINT:
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
- w/ Canister Pump Module:
Refer to INITIALIZATION [11/2018 - 10/2019] , or refer to INITIALIZATION [10/2019 - 08/2020]
- w/o Canister Pump Module:
Refer to INITIALIZATION [11/2018 - 08/2020]
- Install the mass air flow meter sub-assembly with the 2 screws.NOTE:
- If the mass air flow meter sub-assembly has been struck or dropped, replace it.
- If reusing the mass air flow meter sub-assembly, be sure to inspect the O-ring.
- Make sure that the O-ring is not cracked or moved out of place when installing the mass air flow meter sub-assembly.
- Connect the mass air flow meter sub-assembly connector.
- w/ Canister Pump Module: