STA Signal Circuit [08/2020 - 12/2021]: Procedure
- READ VALUE USING TECHSTREAM (STARTER SW)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Data List / Starter SW.
Powertrain > Engine > Data List
Tester Display Starter SW - Read the values displayed on the Techstream when the ignition switch is ON and START.
OK
Techstream Display Condition Normal Condition Starter SW Ignition switch ON OFF Ignition switch START ON Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [10/2019 - 10/2023]
Result:
NG
See step 2
- CHECK HARNESS AND CONNECTOR (ECM - ST NO. 2 RELAY)
- Disconnect the ECM connector.
- Remove the ST NO. 2 relay from the No. 1 engine room relay block and No. 1 junction block assembly.
- Disconnect the engine stop and start ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A24-30 (STA) - 2 (ST NO. 2 relay) Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [10/2019 - 10/2023]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR