DTC P0597-12: Thermostat Heater Control Circuit Short to Battery [11/2018 - 08/2020]: Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK HARNESS AND CONNECTOR (THERMOSTAT HEATER (WATER INLET WITH THERMOSTAT SUB-ASSEMBLY) - ECM)
- Disconnect the thermostat heater (water inlet with thermostat sub-assembly) connector.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition F5-2 (ETM-) or C45-7 (HTHM) - other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE ECM. Refer to REMOVAL [11/2018 - 02/2019] , or refer to REMOVAL [02/2019 - 08/2020]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR