DTC P0403-18: Exhaust Gas Recirculation "A" Circuit Current Below Threshold; DTC P0403-19: Exhaust Gas Recirculation "A" Circuit Current Above Threshold; DTC P1400-18: Exhaust Gas Recirculation "A" Control Circuit 2 Circuit Current Below Threshold; DTC P1400-19: Exhaust Gas Recirculation "A" Control Circuit 2 Circuit Current Above Threshold [06/2020 - 08/2020]: Description
WARNING: This page is about a different variant/trim than selected.
Refer to DTC P0401-9C.
Refer to DTC P0401-9C: Exhaust Gas Recirculation "A" Low / Insufficient Flow [06/2020 - 08/2020]
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P0403-18 | Exhaust Gas Recirculation "A" Circuit Current Below Threshold | Open or short in EGR A circuit for 1 second or more (1 trip detection logic). |
|
Comes on | DTC stored | SAE Code: P0489 |
| P0403-19 | Exhaust Gas Recirculation "A" Circuit Current Above Threshold | Short in EGR A circuit for 1 second or more (1 trip detection logic). |
|
Comes on | DTC stored | SAE Code: P0490 |
| P1400-18 | Exhaust Gas Recirculation "A" Control Circuit 2 Circuit Current Below Threshold | Open or short in EGR B circuit for 1 second or more (1 trip detection logic). |
|
Comes on | DTC stored | SAE Code: P0489 |
| P1400-19 | Exhaust Gas Recirculation "A" Control Circuit 2 Circuit Current Above Threshold | Short in EGR B circuit for 1 second or more (1 trip detection logic). |
|
Comes on | DTC stored | SAE Code: P0490 |