Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
| Duration that both of the following conditions (a) and (b) are met |
6 seconds or more |
| (a) Difference in fuel pressure between actual and target |
3 MPa (30.6 kgf/cm2
, 435 psi) or higher |
| (b) Actual discharge rate of high pressure fuel pump |
0 mm3