Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated) [08/2015 - ]: Procedure
- PERFORM INITIALIZATION
- Initialize the power window regulator motor (Refer to INITIALIZATION [08/2015 - ] ).
- Check if the power window AUTO UP/DOWN function operates (Refer to OPERATION CHECK [08/2015 - 08/2017]
, or refer to OPERATION CHECK [08/2017 - ]
).
OK
AUTO UP/DOWN function operates.
Result:
OK
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result:
NG
See step 2
- CHECK MOVEMENT OF DOOR GLASS
- Remove the installation bolt of the door glass and hold the glass by hand. When raising the glass by hand, check that the glass moves smoothly.NOTE:
- Make sure that the door glass fits into the glass run properly.
- Make sure that the glass run is not deformed, and does not have foreign matter.
OK
Door glass moves smoothly.
Result:
OK
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY (APPLICABLE LOCATION)
(Refer to REMOVAL [08/2015 - 08/2017] , or refer to REMOVAL [08/2017 - ] )
Result:
NG
INSTALL DOOR GLASS AND/OR GLASS RUN PROPERLY
- Remove the installation bolt of the door glass and hold the glass by hand. When raising the glass by hand, check that the glass moves smoothly.