Continuously Variable Valve Lift Controller
CONTINUOUSLY VARIABLE VALVE LIFT CONTROLLER
| Part Tightened | N*m | kgf*cm | ft.*lbf | in.*lbf | |||
|---|---|---|---|---|---|---|---|
| Continuously variable valve lift controller assembly x Camshaft housing sub-assembly | 18 N*m ( | 184 kgf*cm, | 13 ft.*lbf) | ||||
| Wire harness clamp bracket x Camshaft housing sub-assembly | 18 N*m ( | 184 kgf*cm, | 13 ft.*lbf) | ||||
| Purge valve (purge VSV) x Cylinder head cover sub-assembly | 10 N*m ( | 102 kgf*cm, | 7 ft.*lbf) | ||||
| Ignition coil assembly x Cylinder head cover sub-assembly | 10 N*m ( | 102 kgf*cm, | 7 ft.*lbf) | ||||
| Engine wire x Cylinder head cover sub-assembly (Bolt A) | 8.5 N*m ( | 87 kgf*cm, | 75 in.*lbf) | ||||
| Engine wire x Cylinder head cover sub-assembly (Bolt B) | 8.0 N*m ( | 82 kgf*cm, | 71 in.*lbf) | ||||
| Engine wire x Cylinder head sub-assembly (Nut) | 8.0 N*m ( | 82 kgf*cm, | 71 in.*lbf) | ||||