Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch [08/2015 - ]: Procedure
- READ VALUE USING TECHSTREAM (MASTER SWITCH)
- Read the Data List according to the display on the Techstream (Refer to DATA LIST / ACTIVE TEST [08/2015 - ]
).MASTER SWITCH
Tester Display Measurement Item/Range Normal Condition Diagnostic Note D Door P/W Auto SW Driver door power window auto switch signal / OFF or ON OFF: Driver door power window auto switch not being operated
ON: Driver door power window auto switch being operated- OK
On the Techstream screen, ON or OFF is displayed accordingly.
Result:
NG
REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY
(Refer to REMOVAL [08/2015 - ] )
Result:
OK
See step 2
- Read the Data List according to the display on the Techstream (Refer to DATA LIST / ACTIVE TEST [08/2015 - ]
).
- READ VALUE USING TECHSTREAM (D-DOOR MOTOR)
- Read the Data List according to the display on the Techstream (Refer to DATA LIST / ACTIVE TEST [08/2015 - ]
).D-DOOR MOTOR
Tester Display Measurement Item/Range Normal Condition Diagnostic Note D Door P/W Auto SW Driver door power window auto switch signal / OFF or ON OFF: Driver door power window auto switch not being operated
ON: Driver door power window auto switch being operated- OK
On the Techstream screen, ON or OFF is displayed accordingly.
Result:
NG
See step 5
Result:
OK
See step 3
- Read the Data List according to the display on the Techstream (Refer to DATA LIST / ACTIVE TEST [08/2015 - ]
).
- PERFORM INITIALIZATION (FOR DRIVER DOOR)
- Initialize the front power window regulator motor assembly LH (Refer to INITIALIZATION [08/2015 - ] ).
Result:
NEXT
See step 4
- CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP / DOWN FUNCTION)
- Check that the driver door power window moves when the auto up and down function of the multiplex network master switch assembly is operated (Refer to OPERATION CHECK [08/2015 - ]
).
OK
Driver door auto up and down function is normal.
Result:
OK
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result:
NG
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
(Refer to REMOVAL [08/2015 - ] )
- Check that the driver door power window moves when the auto up and down function of the multiplex network master switch assembly is operated (Refer to OPERATION CHECK [08/2015 - ]
).
- REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY
- Replace the multiplex network master switch assembly (Refer to REMOVAL [08/2015 - ] ).
Result:
NEXT
See step 6
- CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP / DOWN FUNCTION)
- Check that the driver door power window moves when the auto up and down function of the multiplex network master switch assembly is operated (Refer to OPERATION CHECK [08/2015 - ]
).
OK
Driver door auto up and down function is normal.
Result:
OK
END (MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY WAS DEFECTIVE)
Result:
NG
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
(Refer to REMOVAL [08/2015 - ] )