Front Passenger Side Power Window Auto Up / Down Function does not Operate with Front Passenger Side Power Window Switch [08/2015 - ]: Procedure
- READ VALUE USING TECHSTREAM (P-DOOR MOTOR)
- Read the Data List according to the display on the Techstream (Refer to DATA LIST / ACTIVE TEST [08/2015 - ]
).P-DOOR MOTOR
Tester Display Measurement Item/Range Normal Condition Diagnostic Note P Door P/W Auto SW Front passenger side power window auto up/down signal / ON or OFF ON: Front passenger side power window auto up/down switch operated
OFF: Front passenger side power window regulator switch not operated- OK
On the Techstream screen, ON or OFF is displayed accordingly.
Result:
NG
See step 4
Result:
OK
See step 2
- Read the Data List according to the display on the Techstream (Refer to DATA LIST / ACTIVE TEST [08/2015 - ]
).
- PERFORM INITIALIZATION (FOR FRONT PASSENGER DOOR)
- Initialize the front power window regulator motor assembly RH (Refer to INITIALIZATION [08/2015 - ] ).
Result:
NEXT
See step 3
- CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP / DOWN FUNCTION)
- Check that the front passenger door power window moves when the auto up and down function of the power window regulator switch assembly is operated (Refer to OPERATION CHECK [08/2015 - ]
).
OK
Front passenger door auto up and down function is normal.
Result:
OK
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result:
NG
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
(Refer to REMOVAL [08/2015 - ] )
- Check that the front passenger door power window moves when the auto up and down function of the power window regulator switch assembly is operated (Refer to OPERATION CHECK [08/2015 - ]
).
- INSPECT POWER WINDOW REGULATOR SWITCH ASSEMBLY
- Remove the power window regulator switch assembly (Refer to REMOVAL [08/2015 - ] ).
- Inspect the power window regulator switch assembly (Refer to INSPECTION [08/2015 - ] ).
Result:
NG
REPLACE POWER WINDOW REGULATOR SWITCH ASSEMBLY
(Refer to REMOVAL [08/2015 - ] )
Result:
OK
See step 5
- CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR SWITCH ASSEMBLY - FRONT POWER WINDOW REGULATOR MOTOR RH)
- Disconnect the I3 power window regulator switch assembly connector.
- Disconnect the I4 front power window regulator motor assembly RH connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition I3-8 (AUTO) - I4-4 (AUTO) Always Below 1 Ω I3-1 (GND) - Body ground Always Below 1 Ω I3-8 (AUTO) or I4-4 (AUTO) - Body ground Always 10 kΩ or higher
Result:
OK
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
(Refer to REMOVAL [08/2015 - ] )
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR