Home >> Toyota >> 2020 >> Prius LE AWD-e >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 12 (Motor Generator Control System (Lithium-Ion Battery) - Diagnostics - Introduction (2 Of 2)) >> MOTOR GENERATOR CONTROL SYSTEM (for LITHIUM-ION BATTERY) >> Diagnostic Trouble Code Chart [11/2015 - 11/2017] >> Diagnostic Trouble Code Chart [11/2015 - 11/2017]
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnostic Trouble Code Chart [11/2015 - 11/2017]

WARNING: This page is about a different variant/trim than selected.
MOTOR GENERATOR CONTROL SYSTEM

DTC No. Detection Item MIL Warning Indicate Link
P0335-00 Crankshaft Position Sensor "A" Does not come on Master Warning Light:
Comes on
Refer to DTC P0335-00: Crankshaft Position Sensor "A"; DTC P0335-31: Crankshaft Position Sensor "A" No Signal [11/2015 - ]
P0335-31 Crankshaft Position Sensor "A" No Signal Does not come on Master Warning Light:
Comes on
Refer to DTC P0335-00: Crankshaft Position Sensor "A"; DTC P0335-31: Crankshaft Position Sensor "A" No Signal [11/2015 - ]
P0340-00 Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Does not come on Master Warning Light:
Comes on
Refer to DTC P0340-00: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor; DTC P0340-31: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal [11/2015 - ]
P0340-31 Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal Does not come on Master Warning Light:
Comes on
Refer to DTC P0340-00: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor; DTC P0340-31: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal [11/2015 - ]
P062F-44 Internal Control Module EEPROM Data Memory Failure Comes on Master Warning Light:
Does not come on
Refer to DTC P062F-44: Internal Control Module EEPROM Data Memory Failure [11/2015 - ]
P062F-46 Generator Control Module (EEPROM Learning Value) Calibration / Parameter Memory Failure Comes on Master Warning Light:
Comes on
Refer to DTC P062F-46: Generator Control Module (EEPROM Learning Value) Calibration / Parameter Memory Failure [11/2015 - ]
P06B0-1C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P06D6-1C Generator Control Module Offset Power Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P0A00-11 Motor Electronics Coolant Temperature Sensor Circuit Short to Ground Comes on Master Warning Light:
Comes on
Refer to DTC P0A00-11: Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; DTC P0A00-15: Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open [11/2015 - ]
P0A00-15 Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open Comes on Master Warning Light:
Comes on
Refer to DTC P0A00-11: Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; DTC P0A00-15: Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open [11/2015 - ]
P0A00-1C Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Refer to DTC P0A00-1C: Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range; DTC P0A00-1F: Motor Electronics Coolant Temperature Sensor Circuit Intermittent [11/2015 - 11/2017]
P0A00-1F Motor Electronics Coolant Temperature Sensor Circuit Intermittent Comes on Master Warning Light:
Comes on
Refer to DTC P0A00-1C: Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range; DTC P0A00-1F: Motor Electronics Coolant Temperature Sensor Circuit Intermittent [11/2015 - 11/2017]
P0A08-12 DC/DC Converter Status Circuit Short to Battery Does not come on Master Warning Light:
Comes on
Refer to DTC P0A08-12: DC/DC Converter Status Circuit Short to Battery; DTC P0A08-14: DC/DC Converter Status Circuit Short to Ground or Open [11/2015 - ]
P0A08-14 DC/DC Converter Status Circuit Short to Ground or Open Does not come on Master Warning Light:
Comes on
Refer to DTC P0A08-12: DC/DC Converter Status Circuit Short to Battery; DTC P0A08-14: DC/DC Converter Status Circuit Short to Ground or Open [11/2015 - ]
P0A11-12 DC/DC Converter Enable Circuit Short to Battery Does not come on Master Warning Light:
Comes on
Refer to DTC P0A11-12: DC/DC Converter Enable Circuit Short to Battery; DTC P0A11-14: DC/DC Converter Enable Circuit Short to Ground or Open [11/2015 - ]
P0A11-14 DC/DC Converter Enable Circuit Short to Ground or Open Does not come on Master Warning Light:
Comes on
Refer to DTC P0A11-12: DC/DC Converter Enable Circuit Short to Battery; DTC P0A11-14: DC/DC Converter Enable Circuit Short to Ground or Open [11/2015 - ]
P0A1A-47 Generator Control Module Watchdog / Safety μC Failure Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P0A1A-49 Generator Control Module Internal Electronic Failure Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P0A1B-1F Generator Control Module Circuit Intermittent Comes on Master Warning Light:
Comes on
Refer to DTC P0A1B-1F: Generator Control Module Circuit Intermittent [11/2015 - 12/2018]
P0A3F-16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0A3F-16: Drive Motor "A" Position Sensor Circuit Voltage Below Threshold; DTC P0A3F-1F: Drive Motor "A" Position Sensor Circuit Intermittent [11/2015 - ]
P0A3F-1F Drive Motor "A" Position Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0A3F-16: Drive Motor "A" Position Sensor Circuit Voltage Below Threshold; DTC P0A3F-1F: Drive Motor "A" Position Sensor Circuit Intermittent [11/2015 - ]
P0A3F-21 Drive Motor "A" Position Sensor Signal Amplitude < Minimum Comes on Master Warning Light:
Comes on
Refer to DTC P0A3F-21: Drive Motor "A" Position Sensor Signal Amplitude < Minimum; DTC P0A3F-22: Drive Motor "A" Position Sensor Signal Amplitude > Maximum [11/2015 - ]
P0A3F-22 Drive Motor "A" Position Sensor Signal Amplitude > Maximum Comes on Master Warning Light:
Comes on
Refer to DTC P0A3F-21: Drive Motor "A" Position Sensor Signal Amplitude < Minimum; DTC P0A3F-22: Drive Motor "A" Position Sensor Signal Amplitude > Maximum [11/2015 - ]
P0A4B-16 Generator Position Sensor Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0A4B-16: Generator Position Sensor Circuit Voltage Below Threshold; DTC P0A4B-1F: Generator Position Sensor Circuit Intermittent [11/2015 - ]
P0A4B-1F Generator Position Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0A4B-16: Generator Position Sensor Circuit Voltage Below Threshold; DTC P0A4B-1F: Generator Position Sensor Circuit Intermittent [11/2015 - ]
P0A4B-21 Generator Position Sensor Signal Amplitude < Minimum Comes on Master Warning Light:
Comes on
Refer to DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A4B-22: Generator Position Sensor Signal Amplitude > Maximum [11/2015 - ]
P0A4B-22 Generator Position Sensor Signal Amplitude > Maximum Comes on Master Warning Light:
Comes on
Refer to DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A4B-22: Generator Position Sensor Signal Amplitude > Maximum [11/2015 - ]
P0A60-12 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery Does not come on Master Warning Light:
Comes on
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [11/2015 - ]
P0A60-14 Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open Does not come on Master Warning Light:
Comes on
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [11/2015 - ]
P0A60-1C Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range Does not come on Master Warning Light:
Comes on
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [11/2015 - ]
P0A60-1F Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [11/2015 - ]
P0A63-12 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery Does not come on Master Warning Light:
Comes on
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [11/2015 - ]
P0A63-14 Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open Does not come on Master Warning Light:
Comes on
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [11/2015 - ]
P0A63-1C Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range Does not come on Master Warning Light:
Comes on
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [11/2015 - ]
P0A63-1F Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [11/2015 - ]
P0A78-73 Drive Motor "A" Inverter Actuator Stuck Closed Comes on Master Warning Light:
Comes on
Refer to DTC P0A78-73: Drive Motor "A" Inverter Actuator Stuck Closed [11/2015 - ]
P0A78-9E Drive Motor "A" Inverter Stuck On Comes on Master Warning Light:
Comes on
Refer to DTC P0A78-9E: Drive Motor "A" Inverter Stuck On; DTC P1C5D-19: Drive Motor "A" Inverter Circuit Current Above Threshold [11/2015 - ]
P0A7A-73 Generator Inverter Actuator Stuck Closed Comes on Master Warning Light:
Comes on
Refer to DTC P0A7A-73: Generator Inverter Actuator Stuck Closed [11/2015 - ]
P0A7A-9E Generator Inverter Stuck On Comes on Master Warning Light:
Comes on
Refer to DTC P0A7A-9E: Generator Inverter Stuck On; DTC P1C5F-19: Generator Inverter Circuit Current Above Threshold [11/2015 - ]
P0A90-00 Drive Motor "A" Performance Comes on Master Warning Light:
Comes on
Refer to DTC P0A90-00: Drive Motor "A" Performance [11/2015 - ]
P0A92-00 Hybrid Generator Performance Comes on Master Warning Light:
Comes on
Refer to DTC P0A92-00: Hybrid Generator Performance [11/2015 - ]
P0A94-9E DC/DC Converter Stuck On Comes on Master Warning Light:
Comes on
Refer to DTC P0A94-9E: DC/DC Converter Stuck On; DTC P0D33-19: DC/DC Converter Circuit Current Above Threshold [11/2015 - ]
P0AED-11 Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground Comes on Master Warning Light:
Comes on
Refer to DTC P0AED-11: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground; DTC P0AED-15: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open [11/2015 - ]
P0AED-15 Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open Comes on Master Warning Light:
Comes on
Refer to DTC P0AED-11: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground; DTC P0AED-15: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open [11/2015 - ]
P0AED-1C Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Refer to DTC P0AED-1C: Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range; DTC P0AED-1F: Drive Motor Inverter Temperature Sensor "A" Circuit Intermittent [11/2015 - 11/2017]
P0AED-1F Drive Motor Inverter Temperature Sensor "A" Circuit Intermittent Comes on Master Warning Light:
Comes on
Refer to DTC P0AED-1C: Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range; DTC P0AED-1F: Drive Motor Inverter Temperature Sensor "A" Circuit Intermittent [11/2015 - 11/2017]
P0BE5-12 Drive Motor "A" Phase U Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0BE5-14 Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0BE5-1F Drive Motor "A" Phase U Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0BE5-28 Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Refer to DTC P0BE5-28: Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BE9-28: Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BED-28: Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [11/2015 - ]
P0BE9-12 Drive Motor "A" Phase V Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0BE9-14 Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0BE9-1F Drive Motor "A" Phase V Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0BE9-28 Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Refer to DTC P0BE5-28: Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BE9-28: Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BED-28: Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [11/2015 - ]
P0BED-12 Drive Motor "A" Phase W Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0BED-14 Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0BED-1F Drive Motor "A" Phase W Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0BED-28 Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Refer to DTC P0BE5-28: Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BE9-28: Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0BED-28: Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [11/2015 - ]
P0BFD-62 Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure Comes on Master Warning Light:
Comes on
Refer to DTC P0BFD-62: Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C67-1F: Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent [11/2015 - ]
P0BFF-1D Drive Motor "A" Circuit Current Out of Range Comes on Master Warning Light:
Comes on
Refer to DTC P0BFF-1D: Drive Motor "A" Circuit Current Out of Range [11/2015 - ]
P0C19-00 Drive Motor "A" Execution Torque Performance Comes on Master Warning Light:
Comes on
Refer to DTC P0C19-00: Drive Motor "A" Execution Torque Performance [11/2015 - ]
P0C38-11 DC/DC Converter Temperature Sensor "A" Circuit Short to Ground Comes on Master Warning Light:
Comes on
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [11/2015 - ]
P0C38-15 DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open Comes on Master Warning Light:
Comes on
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [11/2015 - ]
P0C38-1C DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Refer to DTC P0C38-1C: DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range; DTC P0C38-1F: DC/DC Converter Temperature Sensor "A" Circuit Intermittent [11/2015 - 11/2017]
P0C38-1F DC/DC Converter Temperature Sensor "A" Circuit Intermittent Comes on Master Warning Light:
Comes on
Refer to DTC P0C38-1C: DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range; DTC P0C38-1F: DC/DC Converter Temperature Sensor "A" Circuit Intermittent [11/2015 - 11/2017]
P0C3D-11 DC/DC Converter Temperature Sensor "B" Circuit Short to Ground Comes on Master Warning Light:
Comes on
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [11/2015 - ]
P0C3D-15 DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open Comes on Master Warning Light:
Comes on
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [11/2015 - ]
P0C3D-1C DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Refer to DTC P0C3D-1C: DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range; DTC P0C3D-1F: DC/DC Converter Temperature Sensor "B" Circuit Intermittent [11/2015 - 11/2017]
P0C3D-1F DC/DC Converter Temperature Sensor "B" Circuit Intermittent Comes on Master Warning Light:
Comes on
Refer to DTC P0C3D-1C: DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range; DTC P0C3D-1F: DC/DC Converter Temperature Sensor "B" Circuit Intermittent [11/2015 - 11/2017]
P0C50-13 Drive Motor "A" Position Sensor Circuit "A" Circuit Open Comes on Master Warning Light:
Comes on
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [11/2015 - ]
P0C50-16 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [11/2015 - ]
P0C50-17 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [11/2015 - ]
P0C50-1F Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [11/2015 - ]
P0C5A-13 Drive Motor "A" Position Sensor Circuit "B" Circuit Open Comes on Master Warning Light:
Comes on
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [11/2015 - ]
P0C5A-16 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [11/2015 - ]
P0C5A-17 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [11/2015 - ]
P0C5A-1F Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [11/2015 - ]
P0C64-13 Generator Position Sensor Circuit "A" Circuit Open Comes on Master Warning Light:
Comes on
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [11/2015 - ]
P0C64-16 Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [11/2015 - ]
P0C64-17 Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [11/2015 - ]
P0C64-1F Generator Position Sensor Circuit "A" Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [11/2015 - ]
P0C69-13 Generator Position Sensor Circuit "B" Circuit Open Comes on Master Warning Light:
Comes on
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [11/2015 - ]
P0C69-16 Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [11/2015 - ]
P0C69-17 Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [11/2015 - ]
P0C69-1F Generator Position Sensor Circuit "B" Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [11/2015 - ]
P0C79-17 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0C79-17: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold [11/2015 - ]
P0CA3-00 DC/DC Converter Step Up Voltage Performance Comes on Master Warning Light:
Comes on
Refer to DTC P0CA3-00: DC/DC Converter Step Up Voltage Performance [11/2015 - ]
P0D2D-16 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold; DTC P0D2D-17: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold; DTC P0D2D-1F: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent [11/2015 - ]
P0D2D-17 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold; DTC P0D2D-17: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold; DTC P0D2D-1F: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent [11/2015 - ]
P0D2D-1F Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold; DTC P0D2D-17: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold; DTC P0D2D-1F: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent [11/2015 - ]
P0D33-19 DC/DC Converter Circuit Current Above Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0A94-9E: DC/DC Converter Stuck On; DTC P0D33-19: DC/DC Converter Circuit Current Above Threshold [11/2015 - ]
P0DFA-62 Generator Phase U-V-W Current Sensor Signal Compare Failure Comes on Master Warning Light:
Comes on
Refer to DTC P0DFA-62: Generator Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C69-1F: Generator Phase U-V-W Current Sensor Circuit Intermittent [11/2015 - ]
P0E00-12 Generator Phase U Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0E00-14 Generator Phase U Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0E00-1F Generator Phase U Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0E00-28 Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E04-28: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E08-28: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [11/2015 - ]
P0E04-12 Generator Phase V Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0E04-14 Generator Phase V Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0E04-1F Generator Phase V Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0E04-28 Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E04-28: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E08-28: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [11/2015 - ]
P0E08-12 Generator Phase W Current Sensor Circuit Short to Battery Comes on Master Warning Light:
Comes on
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0E08-14 Generator Phase W Current Sensor Circuit Short to Ground or Open Comes on Master Warning Light:
Comes on
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0E08-1F Generator Phase W Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [11/2015 - ]
P0E08-28 Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning Light:
Comes on
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E04-28: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E08-28: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [11/2015 - ]
P0E31-16 DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E31-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E31-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [11/2015 - ]
P0E31-17 DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E31-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E31-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [11/2015 - ]
P0E31-1F DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E31-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E31-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [11/2015 - ]
P0E51-11 DC/DC Converter Current Sensor Circuit Short to Ground Comes on Master Warning Light:
Comes on
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E51-15: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E51-1F: DC/DC Converter Current Sensor Circuit Intermittent [11/2015 - ]
P0E51-15 DC/DC Converter Current Sensor Circuit Short to Battery or Open Comes on Master Warning Light:
Comes on
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E51-15: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E51-1F: DC/DC Converter Current Sensor Circuit Intermittent [11/2015 - ]
P0E51-1C DC/DC Converter Current Sensor Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Refer to DTC P0E51-1C: DC/DC Converter Current Sensor Circuit Voltage Out of Range [11/2015 - ]
P0E51-1F DC/DC Converter Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E51-15: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E51-1F: DC/DC Converter Current Sensor Circuit Intermittent [11/2015 - ]
P0E51-2A DC/DC Converter Current Sensor Signal Stuck In Range Comes on Master Warning Light:
Comes on
Refer to DTC P0E51-2A: DC/DC Converter Current Sensor Signal Stuck In Range [11/2015 - ]
P0E57-17 DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0E57-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold [11/2015 - ]
P0E71-00 Generator Execution Torque Performance Comes on Master Warning Light:
Comes on
Refer to DTC P0E71-00: Generator Execution Torque Performance [11/2015 - ]
P1C2A-1C Generator A/D Converter Circuit Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P1C2A-49 Generator A/D Converter Circuit Internal Electronic Failure Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P1C2B-1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P1C2B-49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P1C2E-46 Motor Generator ECU (EEPROM) Calibration / Parameter Memory Failure Does not come on Master Warning Light:
Comes on
Refer to DTC P1C2E-46: Motor Generator ECU (EEPROM) Calibration / Parameter Memory Failure [11/2015 - ]
P1C5D-19 Drive Motor "A" Inverter Circuit Current Above Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0A78-9E: Drive Motor "A" Inverter Stuck On; DTC P1C5D-19: Drive Motor "A" Inverter Circuit Current Above Threshold [11/2015 - ]
P1C5F-19 Generator Inverter Circuit Current Above Threshold Comes on Master Warning Light:
Comes on
Refer to DTC P0A7A-9E: Generator Inverter Stuck On; DTC P1C5F-19: Generator Inverter Circuit Current Above Threshold [11/2015 - ]
P1C60-1F Generator Control Module Position Sensor REF Power Source Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P1C62-1F Generator Control Module Offset Power Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P1C64-1F Generator Control Module Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C64-1F: Generator Control Module Circuit Intermittent; DTC P1CAF-38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [11/2015 - ]
P1C65-1F Generator Control Module Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C65-1F: Generator Control Module Circuit Intermittent; DTC P1CB0-38: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [11/2015 - ]
P1C67-1F Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0BFD-62: Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C67-1F: Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent [11/2015 - ]
P1C69-1F Generator Phase U-V-W Current Sensor Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P0DFA-62: Generator Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C69-1F: Generator Phase U-V-W Current Sensor Circuit Intermittent [11/2015 - ]
P1CA5-1D Hybrid Generator Circuit Current Out of Range Comes on Master Warning Light:
Comes on
Refer to DTC P1CA5-1D: Hybrid Generator Circuit Current Out of Range [11/2015 - ]
P1CAC-49 Generator Position Sensor Internal Electronic Failure Comes on Master Warning Light:
Comes on
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C64-1F: Generator Control Module Circuit Intermittent; DTC P1CAF-38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [11/2015 - ]
P1CAD-49 Drive Motor "A" Position Sensor Internal Electronic Failure Comes on Master Warning Light:
Comes on
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C65-1F: Generator Control Module Circuit Intermittent; DTC P1CB0-38: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [11/2015 - ]
P1CAF-38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect Comes on Master Warning Light:
Comes on
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C64-1F: Generator Control Module Circuit Intermittent; DTC P1CAF-38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [11/2015 - ]
P1CB0-38 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect Comes on Master Warning Light:
Comes on
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C65-1F: Generator Control Module Circuit Intermittent; DTC P1CB0-38: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [11/2015 - ]
P1CB5-9E DC/DC Converter Voltage Sensor "A"(VL) Stuck On Comes on Master Warning Light:
Comes on
Refer to DTC P1CB5-9E: DC/DC Converter Voltage Sensor "A"(VL) Stuck On [11/2015 - ]
P1CB6-9E Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On Comes on Master Warning Light:
Comes on
Refer to DTC P1CB6-9E: Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On [11/2015 - ]
P1CB7-46 Generator Control Module (EEPRM Backup Power) Calibration / Parameter Memory Failure Does not come on Master Warning Light:
Comes on
Refer to DTC P1CB7-46: Generator Control Module (EEPRM Backup Power) Calibration / Parameter Memory Failure [11/2015 - 12/2018]
P1CB7A2 Motor Generator System Voltage Low Does not come on Master Warning Light:
Comes on
Refer to DTC P1CB7-A2: Motor Generator System Voltage Low [11/2015 - 12/2018]
P1CCC-96 DC/DC Converter Enable Component Internal Failure Does not come on Master Warning Light:
Comes on
Refer to DTC P1CCC-96: DC/DC Converter Enable Component Internal Failure [11/2015 - ]
P3124-1F Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent Does not come on Master Warning Light:
Does not come on
Refer to DTC P3124-1F: Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent; DTC P3124-87: Lost Communication between Drive Motor "A" and HV ECU Missing Message [11/2015 - ]
P3124-87 Lost Communication between Drive Motor "A" and HV ECU Missing Message Does not come on Master Warning Light:
Comes on
Refer to DTC P3124-1F: Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent; DTC P3124-87: Lost Communication between Drive Motor "A" and HV ECU Missing Message [11/2015 - ]
P3133-83 Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P3133-86 Communication Error from Generator to Drive Motor "A" Signal Invalid Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P3133-87 Communication Error from Generator to Drive Motor "A" Missing Message Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P3134-83 Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P3134-86 Communication Error from Drive Motor "A" to Generator Signal Invalid Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P3134-87 Communication Error from Drive Motor "A" to Generator Missing Message Comes on Master Warning Light:
Comes on
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range; DTC P0A1A-47: Generator Control Module Watchdog / Safety μC Failure; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit Circuit Voltage Out of Range; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [11/2015 - ]
P314F-1F DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent Comes on Master Warning Light:
Comes on
Refer to DTC P314F-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [11/2015 - ]
P3153-1D DC/DC Converter Current Sensor Circuit Current Out of Range Does not come on Master Warning Light:
Comes on
Refer to DTC P3153-1D: DC/DC Converter Current Sensor Circuit Current Out of Range [11/2015 - ]
U0100-87 Lost Communication With ECM/PCM "A" Missing Message Comes on Master Warning Light:
Comes on
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U0293-87: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U1170-87: Lost Communication With Brake System Control Module (ch2) Missing Message [11/2015 - 12/2018]
U0293-87 Lost Communication With Hybrid Powertrain Control Module Missing Message Comes on Master Warning Light:
Comes on
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U0293-87: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U1170-87: Lost Communication With Brake System Control Module (ch2) Missing Message [11/2015 - 12/2018]
U1170-87 Lost Communication With Brake System Control Module (ch2) Missing Message Does not come on Master Warning Light:
Comes on
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U0293-87: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U1170-87: Lost Communication With Brake System Control Module (ch2) Missing Message [11/2015 - 12/2018]