Monitor Result
Refer to detailed information in Checking Monitor Status.
Refer to CHECKING MONITOR STATUS [09/2016 - ]
P2401: EVAPORATIVE SYSTEM / VACUUM PMP OFF
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $CB | Multiply by 0.001 | kPa | Test value for leak detection pump stuck OFF |
P2402: EVAPORATIVE SYSTEM / VACUUM PMP ON
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $CD | Multiply by 0.001 | kPa | Test value for leak detection pump stuck ON |
P2420: EVAPORATIVE SYSTEM / VENT VALVE OFF
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $CE | Multiply by 0.001 | kPa | Test value for vent valve stuck off |
P2419: EVAPORATIVE SYSTEM / VENT VALVE ON
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $CF | Multiply by 0.001 | kPa | Test value for vent valve stuck on |
P043E: EVAPORATIVE SYSTEM / ORIFICE CLOGGED
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $D0 | Multiply by 0.001 | kPa | Test value for reference orifice low flow |
P043F: EVAPORATIVE SYSTEM / ORIFICE HI-FLW
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $D1 | Multiply by 0.001 | kPa | Test value for reference orifice high flow |
P0441: EVAPORATIVE SYSTEM / PURGE VSV CLOSED
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $D4 | Multiply by 0.001 | kPa | Test value for purge VSV stuck closed |
P0441: EVAPORATIVE SYSTEM / PURGE VSV OPENED
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $D5 | Multiply by 0.001 | kPa | Test value for purge VSV stuck open |
P0441: EVAPORATIVE SYSTEM / PURGE FLOW
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $D7 | Multiply by 0.001 | kPa | Test value for purge flow insufficient |
P1420: EVAPORATIVE SYSTEM / CNST SMALL LEAK
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $D8 | Multiply by 0.001 | kPa | Test value for canister small leak |
P1421: EVAPORATIVE SYSTEM / CNST GROSS LEAK
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $D9 | Multiply by 0.001 | kPa | Test value for canister gross leak |
P1422: EVAPORATIVE SYSTEM / TANK SMALL LEAK
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $DA | Multiply by 0.001 | kPa | Test value for fuel tank small leak |
P1423: EVAPORATIVE SYSTEM / TANK GROSS LEAK
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $DB | Multiply by 0.001 | kPa | Test value for fuel tank gross leak |
P2451: EVAPORATIVE SYSTEM / TANK CLS VAL OP
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $DC | Multiply by 0.001 | kPa | Test value for tank closed valve close stuck |
P2450: EVAPORATIVE SYSTEM / TANK CLS VAL CL
| Monitor ID | Test ID | Scaling | Unit | Description |
|---|---|---|---|---|
| $3D | $DD | Multiply by 0.001 | kPa | Test value for tank closed valve open stuck |