Home >> Toyota >> 2021 >> C-HR LE >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System (W/O Canister Pump) - Diagnostic Codes (P0010-P0351) >> SFI SYSTEM (w/o Canister Pump Module) >> DTC P0107: Manifold Absolute Pressure / Barometric Pressure Circuit Low Input; DTC P0108: Manifold Absolute Pressure / Barometric Pressure Circuit High Input [10/2017 - 12/2021] >> Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC P0107: Manifold Absolute Pressure / Barometric Pressure Circuit Low Input; DTC P0108: Manifold Absolute Pressure / Barometric Pressure Circuit High Input [10/2017 - 12/2021]: Description

The manifold absolute pressure sensor detects pressure inside the intake manifold as an absolute pressure with a built-in sensor and outputs a voltage. Based on the voltage from the manifold absolute pressure sensor, the ECM controls the purge VSV and corrects any errors in the air fuel ratio due to change in pressure.

GTY319518Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0107 Manifold Absolute Pressure / Barometric Pressure Circuit Low Input The output voltage from the manifold absolute pressure sensor below 0.5 V for 0.5 seconds (1 trip detection logic).
  • Open or short in manifold absolute pressure sensor circuit
  • Manifold absolute pressure sensor
  • ECM
Comes on DTC stored
P0108 Manifold Absolute Pressure / Barometric Pressure Circuit High Input The output voltage from the manifold absolute pressure sensor higher than 4.5 V for 0.5 seconds (1 trip detection logic).
  • Open or short in manifold absolute pressure sensor circuit
  • Manifold absolute pressure sensor
  • ECM
Comes on DTC stored

HINT: 

When either of these DTCs is output, check the manifold absolute pressure using the Techstream. Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / MAP.

Manifold Absolute Pressure Malfunction
Approximately 0 kPa (abs) [0 mmHg (abs)]
  • Short in PIM circuit to ground
  • Short in PIM circuit to EPIM circuit
  • Open in VCPM circuit
130 kPa (abs) [975 mmHg (abs)] or higher
  • Short in VCPM circuit to PIM circuit
  • Open in PIM circuit
  • Open in EPIM circuit