Installation [02/2017 - 08/2020]: Procedure
- INSTALL NO. 2 ECM BRACKET
- Install the No. 2 ECM bracket to the ECM with the 2 screws.
Torque: 4.5 N*m (46 kgf*cm, 40 in.*lbf)
- Install the No. 2 ECM bracket to the ECM with the 2 screws.
- INSTALL NO. 1 ECM BRACKET
- Install the No. 1 ECM bracket to the ECM with the 2 screws.
Torque: 4.5 N*m (46 kgf*cm, 40 in.*lbf)
- Install the No. 1 ECM bracket to the ECM with the 2 screws.
- INSTALL ECM
- Install the ECM with the bolt and nut.
Bolt
Torque: 12.5 N*m (127 kgf*cm, 9 ft.*lbf)
Nut
Torque: 8.0 N*m (82 kgf*cm, 71 in.*lbf)
NOTE:If the ECM has been struck or dropped, replace it.
- Engage the 2 claws to connect the engine wire to the No. 1 engine room relay block.
- Connect the 3 connectors to the engine room relay block assembly.
- Install the No. 1 relay block cover to the No. 1 engine room relay block.
- Connect the 2 ECM connectors and lower the 2 levers.NOTE:
- When connecting the ECM connectors, make sure that dirt, water or other foreign matter does not contact the connecting parts of the ECM connectors.
- Be sure to securely connect the ECM connectors.
- Install the ECM with the bolt and nut.
- INSTALL AIR CLEANER CASE SUB-ASSEMBLY
- Install the air cleaner case sub-assembly to the vehicle with the 2 bolts.
Torque: 4.0 N*m (41 kgf*cm, 35 in.*lbf)
- Install the air cleaner filter element sub-assembly to the air cleaner case sub-assembly.
- Install the air cleaner case sub-assembly to the vehicle with the 2 bolts.
- INSTALL NO. 1 AIR CLEANER INLET
Refer to PROCEDURE - STEP 23 [02/2017 - 10/2017] , or refer to PROCEDURE - STEP 24 [10/2017 - 05/2018] , or refer to PROCEDURE - STEP 25 [05/2018 - 09/2019] , or refer to PROCEDURE - STEP 26 [09/2019 - 12/2021]
- INSTALL RADIATOR COVER
Refer to PROCEDURE - STEP 4 [02/2017 - 10/2017] , or refer to PROCEDURE - STEP 4 [10/2017 - 09/2019] , or refer to PROCEDURE - STEP 4 [09/2019 - ]
- INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE
See step 3 [02/2017 - 10/2017] See step 3 [10/2017 - 12/2021]
- INSTALL NO. 2 CYLINDER HEAD COVER
See step 4
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Refer to PROCEDURE - STEP 2
NOTE:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Refer to INITIALIZATION [02/2017 - 10/2017] , or refer to INITIALIZATION [10/2017 - 05/2018] , or refer to INITIALIZATION [05/2018 - 09/2019] , or refer to INITIALIZATION [09/2019 - 08/2020]
- PERFORM INITIALIZATION
Refer to INITIALIZATION [02/2017 - 10/2017] , or refer to INITIALIZATION [10/2017 - 05/2018] , or refer to INITIALIZATION [05/2018 - 09/2019] , or refer to INITIALIZATION [09/2019 - 08/2020]