LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2021 >> Prius Limited >> Repair and Diagnosis >> Quick Lookups >> DTC Index >> Hybrid / Battery Control DTCS >> Rear Motor Generator Control System
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Rear Motor Generator Control System

REAR MOTOR GENERATOR CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION

DTC Code Description
P06B3-1C Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P0A1C-1F Drive Motor "B" Control Module Circuit Intermittent
P0A45-16 Drive Motor "B" Position Sensor Circuit Voltage Below Threshold
P0A45-1F Drive Motor "B" Position Sensor Circuit Intermittent
P0A45-21 Drive Motor "B" Position Sensor Signal Amplitude < Minimum
P0A45-22 Drive Motor "B" Position Sensor Signal Amplitude > Maximum
P0A69-12 Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery
P0A69-14 Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open
P0A69-1C Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range
P0A69-1F Drive Motor "B" Phase V Current(High Resolution) Circuit Intermittent
P0A6C-12 Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery
P0A6C-14 Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open
P0A6C-1C Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range
P0A6C-1F Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent
P0A79-9E Drive Motor "B" Inverter Stuck On
P0AF2-11 Drive Motor Inverter Temperature Sensor "B" Circuit Short to Ground
P0AF2-15 Drive Motor Inverter Temperature Sensor "B" Circuit Short to Battery or Open
P0AF2-1F Drive Motor Inverter Temperature Sensor "B" Circuit Intermittent
P0BD1-11 Drive Motor Inverter Temperature Sensor "C" Circuit Circuit Short to Ground
P0BD1-15 Drive Motor Inverter Temperature Sensor "C" Circuit Circuit Short to Battery or Open
P0BD1-1F Drive Motor Inverter Temperature Sensor "C" Circuit Circuit Intermittent
P0BF5-12 Drive Motor "B" Phase V Current Sensor Circuit Short to Battery
P0BF5-14 Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open
P0BF5-1F Drive Motor "B" Phase V Current Sensor Circuit Intermittent
P0BF5-28 Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BF9-12 Drive Motor "B" Phase W Current Sensor Circuit Short to Battery
P0BF9-14 Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open
P0BF9-1F Drive Motor "B" Phase W Current Sensor Circuit Intermittent
P0BF9-28 Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0C02-1D Drive Motor "B" System Circuit Current Out of Range
P0C1A-00 Drive Motor "B" Execution Torque Performance
P0C31-00 Drive Motor Inverter Temperature Sensor "C" Circuit
P0C55-13 Drive Motor "B" Position Sensor Circuit "A" Circuit Open
P0C55-16 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C55-17 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C55-1F Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent
P0C5F-13 Drive Motor "B" Position Sensor Circuit "B" Circuit Open
P0C5F-16 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5F-17 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0C5F-1F Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent
P0C7A-17 Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold
P0DA3-16 Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold
P0DA3-17 Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold
P0DA3-1F Drive Motor "B" Inverter Voltage Sensor "A" Circuit Intermittent
P1C2C-1C Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range
P1C2C-49 Drive Motor "B" Control Module AD Converter Circuit Internal Electronic Failure
P1C5E-19 Drive Motor "B" Inverter Circuit Current Above Threshold
P1C61-1F Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Intermittent
P1C63-1F Drive Motor "B" Control Module Offset Power Circuit Intermittent
P1C66-1F Drive Motor "B" Control Module Circuit Intermittent
P1CAE-49 Drive Motor "B" Position Sensor Internal Electronic Failure
P1CB1-38 Drive Motor "B" Position Sensor REF Signal Frequency Incorrect
P1CE4-9E Drive Motor "B" Inverter Voltage Sensor "A" Stuck On
P262C-1C Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range
P3104-62 Drive Motor Inverter Temperature Sensor "B" Signal Compare Failure
P3149-1F Lost Communication between Drive Motor "A" and "B" Circuit Intermittent
P3149-87 Lost Communication between Drive Motor "A" and "B" Missing Message
P31E4-1F Drive Motor "B" Phase V Current Sensor Circuit Intermittent
P31E5-1F Drive Motor "B" Phase W Current Sensor Circuit Intermittent
P33C0-12 Drive Motor "B" Phase V Current Sensor Sub Circuit Short to Battery
P33C0-14 Drive Motor "B" Phase V Current Sensor Sub Circuit Short to Ground or Open
P33C0-1F Drive Motor "B" Phase V Current Sensor Sub Circuit Intermittent
P33C0-28 Drive Motor "B" Phase V Current Sensor Sub Signal Bias Level Out of Range / Zero Adjustment Failure
P33C5-12 Drive Motor "B" Phase W Current Sensor Sub Circuit Short to Battery
P33C5-14 Drive Motor "B" Phase W Current Sensor Sub Circuit Short to Ground or Open
P33C5-1F Drive Motor "B" Phase W Current Sensor Sub Circuit Intermittent
P33C5-28 Drive Motor "B" Phase W Current Sensor Sub Signal Bias Level Out of Range / Zero Adjustment Failure
P33D8-62 Drive Motor "B" Phase V Current Sensor Signal Compare Failure
P33D9-62 Drive Motor "B" Phase W Current Sensor Signal Compare Failure