Remote Up / Down Function does not Operate [11/2018 - ]: Procedure
- READ VALUE USING TECHSTREAM (MASTER SWITCH)
- Using the Techstream, read the data for the condition when the multiplex network master switch assembly was operated.
Refer to DATA LIST / ACTIVE TEST [11/2018 - 10/2023] , or refer to DATA LIST / ACTIVE TEST [10/2023 - 11/2024] , or refer to DATA LIST / ACTIVE TEST [11/2024 - ]
Body Electrical > Master Switch > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note P Door P/W Auto SW Front passenger door power window auto up and down switch signal OFF or ON OFF: Front passenger door power window auto switch not being operated
ON: Front passenger door power window auto switch being operated- RR Door P/W Auto SW Rear RH door power window auto up and down switch signal OFF or ON OFF: Rear RH door power window auto switch not being operated
ON: Rear RH door power window auto switch being operated- RL Door P/W Auto SW Rear LH door power window auto up and down switch signal OFF or ON OFF: Rear LH door power window auto switch not being operated
ON: Rear LH door power window auto switch being operated- P Door P/W Up SW Front passenger door power window manual up switch signal OFF or ON OFF: Front passenger door power window manual up switch not being operated
ON: Front passenger door power window manual up switch being operated- RR Door P/W up switch Rear RH door power window manual up switch signal OFF or ON OFF: Rear RH door power window manual up switch not being operated
ON: Rear RH door power window manual up switch being operated- RL Door P/W up switch Rear LH door power window manual up switch signal OFF or ON OFF: Rear LH door power window manual up switch not being operated
ON: Rear LH door power window manual up switch being operated- Body Electrical > Master Switch > Data List
Tester Display P Door P/W Auto SW RR Door P/W Auto SW RL Door P/W Auto SW P Door P/W Up SW RR Door P/W up switch RL Door P/W up switch OK
On the Techstream screen, ON or OFF is displayed accordingly.
Result
Result Proceed to NG A OK (when the window for which remote operation is impossible is the front passenger side window) B OK (when the window for which remote operation is impossible is the rear right side window) C OK (when the window for which remote operation is impossible is the rear left side window) D
Result:
A
REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY
Refer to REMOVAL [11/2018 - ]
Result:
B
REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
Refer to REMOVAL [11/2018 - 02/2019] , or refer to REMOVAL [02/2019 - 10/2019] , or refer to REMOVAL [10/2019 - 08/2020] , or refer to REMOVAL [08/2020 - 12/2021] , or refer to REMOVAL [12/2021 - 10/2022] , or refer to REMOVAL [10/2022 - 10/2023] , or refer to REMOVAL [10/2023 - ]
Result:
C
REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
Refer to REMOVAL [11/2018 - 02/2019] , or refer to REMOVAL [02/2019 - 10/2019] , or refer to REMOVAL [10/2019 - 08/2020] , or refer to REMOVAL [08/2020 - 12/2021] , or refer to REMOVAL [12/2021 - 10/2022] , or refer to REMOVAL [10/2022 - 10/2023] , or refer to REMOVAL [10/2023 - ]
Result:
D
REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
Refer to REMOVAL [11/2018 - 02/2019] , or refer to REMOVAL [02/2019 - 10/2019] , or refer to REMOVAL [10/2019 - 08/2020] , or refer to REMOVAL [08/2020 - 12/2021] , or refer to REMOVAL [12/2021 - 10/2022] , or refer to REMOVAL [10/2022 - 10/2023] , or refer to REMOVAL [10/2023 - ]
- Using the Techstream, read the data for the condition when the multiplex network master switch assembly was operated.