Stop and Start Cancel Switch Circuit [10/2023 - ]: Procedure
- READ VALUE USING TECHSTREAM (STOP&START CANCEL SWITCH)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Powertrain / Stop and Start / Data List / Stop&Start Cancel Switch.
Powertrain > Stop and Start > Data List
Tester Display Stop&Start Cancel Switch - Read the value when the stop and start system cancel switch (eco run cancel switch assembly) is pressed.
OK
Techstream Display Condition Normal Condition Stop&Start Cancel Switch Stop and start system cancel switch (eco run cancel switch assembly) is pressed ON Stop and start system cancel switch (eco run cancel switch assembly) is not pressed OFF Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [10/2023 - ]
Result:
NG
See step 2
- INSPECT STOP AND START SYSTEM CANCEL SWITCH (ECO RUN CANCEL SWITCH ASSEMBLY)
- Inspect the stop and start system cancel switch (eco run cancel switch assembly).
Refer to INSPECTION [11/2018 - ]
Result
Proceed to OK NG
Result:
NG
REPLACE STOP AND START SYSTEM CANCEL SWITCH (ECO RUN CANCEL SWITCH ASSEMBLY). Refer to REMOVAL [10/2023 - ]
Result:
OK
See step 3
- Inspect the stop and start system cancel switch (eco run cancel switch assembly).
- CHECK HARNESS AND CONNECTOR (STOP AND START SYSTEM CANCEL SWITCH (ECO RUN CANCEL SWITCH ASSEMBLY) - BODY GROUND)
- Disconnect the stop and start system cancel switch (eco run cancel switch assembly) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G51-2 (E) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - STOP AND START SYSTEM CANCEL SWITCH (ECO RUN CANCEL SWITCH ASSEMBLY))
- Disconnect the engine stop and start ECU connector.
- Disconnect the stop and start system cancel switch (eco run cancel switch assembly) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A32-5 (ECAN) - G51-5 (ECU) Always Below 1 Ω A32-5 (ECAN) or G51-5 (ECU) - Body ground and other terminals Always 10 kΩ or higher Result
Proceed to OK NG
Result:
OK
REPLACE ENGINE STOP AND START ECU. Refer to REMOVAL [10/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR