Component Operating Range
U0110 (CASE 2)
| Communication status with inverter with converter assembly (PL-Bus) | Valid |
U0129
| All of the following conditions are met | - |
| VM1 voltage | Higher than 7.3 V, and less than 23.2 V |
| IGR voltage | Higher than 9.5 V |
| Communication status with ECB* (C1-Bus) | Valid |
*: Electronically Controlled Brake System
U0293 (CASE 2)
| Both of the following conditions are met | - |
| Communication status with hybrid vehicle control ECU (C1-Bus) send at IGP power on | Valid |
| Communication status with hybrid vehicle control ECU (C1-Bus) send at IGR power on | Valid |
U1150 (CASE 2)
| Both of the following conditions are met | - |
| Communication status with hybrid vehicle control ECU (PL-Bus) send at IGP power on | Valid |
| Communication status with hybrid vehicle control ECU (PL-Bus) send at IGR power on | Valid |
U117D
| All of the following conditions are met | - |
| VM1 voltage | Higher than 7.3 V, and less than 23.2 V |
| IGR voltage | Higher than 9.5 V |
| Communication status with ECB* (PL-Bus) | Valid |
*: Electronically Controlled Brake System