DTC C1AC2: Slave Module Horizontal Axis Misalignment [08/2021 - ]: Procedure
- CHECK INSTALLATION CONDITION
- Check the installation condition of the blind spot monitor sensor RH.
Refer to ADJUSTMENT [08/2021 - ]
HINT:
Take the appropriate action in accordance with the result.
Result:
NEXT
See step 2
- Check the installation condition of the blind spot monitor sensor RH.
- PERFORM BEAM AXIS CONFIRMATION
- Install the rear bumper.
- w/ Mudguard
Refer to INSTALLATION [08/2021 - ]
- w/o Mudguard
Refer to INSTALLATION [08/2021 - ]
- w/ Mudguard
- Perform Blind Spot Monitor Beam Axis Confirmation using the Techstream.
Refer to ADJUSTMENT [08/2021 - ]
Result:
OK
END
Result:
NG
REPLACE BLIND SPOT MONITOR SENSOR RH. Refer to REMOVAL [08/2021 - ]
- Install the rear bumper.