DTC P0038: A/F / O2 Heater Control Circuit High Bank 1 Sensor 2 [11/2021 - ]: Procedure
- CHECK HARNESS BETWEEN ECM AND HEATED OXYGEN SENSOR CONNECTOR (SHORT TO POWER SUPPLY)
- Turn the ignition switch to OFF.
- Disconnect the connector from ECM.
- Measure the voltage between ECM connector and engine ground.
Connector & terminal
B1-7 (RO2HR) - Engine ground
Is the voltage 10 V or higher?
Result Proceed to Yes (Repair the short circuit to power supply in harness between ECM connector and heated oxygen sensor connector.) A No B
Result:
A
REPAIR HARNESS
Result:
B
See step 2
- CHECK GROUND CIRCUIT FOR ECM (OPEN CIRCUIT)
- Measure the resistance between the ECM connector and engine ground.
Connector & terminal
A5-69 (GNDEG3) - Engine ground
A5-70 (GNDEG4) - Engine ground
A5-71 (GNDEG1) - Engine ground
A5-72 (GNDEG2) - Engine ground
Is the resistance less than 5 Ω?
Result Proceed to Yes (Check the heated oxygen sensor.) A No (Repair the following item.) - Open circuit of harness between ECM connector and engine ground
- Poor contact of coupling connector
B
Result:
A
CHECK HEATED OXYGEN SENSOR. Refer to INSPECTION [11/2021 - ]
Result:
B
REPAIR RELATED PARTS
- Measure the resistance between the ECM connector and engine ground.