LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Toyota >> 2023 >> GR86 Base, Automatic Trans >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System - Diagnostic Codes (6 Of 6) & Circuit Tests >> SFI System >> DTC P2401: EVAP System Leak Detection Pump Control Circuit Low [11/2021 - ] >> Monitor Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Monitor Description

OUTLINE OF DIAGNOSIS 

Detect the open or short circuit of the vacuum pump in canister pump module.

Judge as NG if out of specification.

COMPONENT DESCRIPTION 

GTY1050988Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
*1 Canister pump module *2 Switching valve
*3 Reference orifice (0.02 inch orifice) *4 Pressure sensor
*5 Vacuum pump *6 Drain filter
*7 Purge valve *8 Intake manifold
*9 Fuel tank assembly *10 Charcoal canister assembly

EXECUTION CONDITION 

Secondary parameters Execution condition
Ignition switch or soaking timer ON
Battery voltage 10.9 V or higher
Vacuum pump drive signal in the canister pump module OFF

GENERAL DRIVING CYCLE 

Always perform the diagnosis continuously.

DIAGNOSTIC METHOD 

If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.

Judgment value 

Malfunction Criteria Threshold Value
Voltage detected by vacuum pump in the canister pump module 3 V or less

Time needed for diagnosis 

2500 ms

Malfunction indicator light illumination 

Illuminates as soon as a malfunction occurs.