Diagnostic Trouble Code Chart [03/2023 - 01/2025]
WARNING: This page is about a different car, the 2025 Toyota Prius, 2024 Toyota Prius Prime, and 2023 Toyota Prius Prime. However, it is still accessible from the selected car via links, so may be relevant.
PLUG-IN CHARGE CONTROL SYSTEM
| DTC No. | Detection Item | MIL | Warning Indicate | DTC Output from | Priority | Note | Link |
|---|---|---|---|---|---|---|---|
| P0560-14 | System Voltage (BATT) Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0562 |
Refer to DTC P0560-14: System Voltage (BATT) Circuit Short to Ground or Open [03/2023 - ] |
| P060B-1C | Plug-in Control Module A/D Processing Circuit Voltage Out of Range | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P060B |
Refer to DTC P060B-1C: Plug-in Control Module A/D Processing Circuit Voltage Out of Range; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P060B-71: Plug-in Control Module A/D Processing Actuator Stuck [03/2023 - ] |
| P060B-49 | Plug-in Control Module A/D Processing Internal Electronic Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P060B |
Refer to DTC P060B-1C: Plug-in Control Module A/D Processing Circuit Voltage Out of Range; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P060B-71: Plug-in Control Module A/D Processing Actuator Stuck [03/2023 - ] |
| P060B-71 | Plug-in Control Module A/D Processing Actuator Stuck | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P060B |
Refer to DTC P060B-1C: Plug-in Control Module A/D Processing Circuit Voltage Out of Range; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P060B-71: Plug-in Control Module A/D Processing Actuator Stuck [03/2023 - ] |
| P062F-44 | Plug-in Control Module EEPROM Data Memory Failure | Comes on | Master Warning: Does not come on |
Plug-in Control | A | SAE Code: P062F |
Refer to DTC P062F-44: Plug-in Control Module EEPROM Data Memory Failure [03/2023 - ] |
| P0688-1F | Plug-in Control Module Power Relay Sense Circuit Intermittent | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P2511 |
Refer to DTC P0688-1F: Plug-in Control Module Power Relay Sense Circuit Intermittent [03/2023 - ] |
| P0D07-00 | Hybrid/EV Battery Charging System Positive Contactor Stuck Closed | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D08 | Refer to DTC P0D07-00: Hybrid/EV Battery Charging System Positive Contactor Stuck Closed [03/2023 - 01/2025] |
| P0D07-73 | Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D08 | Refer to DTC P0D07-73: Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed [03/2023 - 01/2025] |
| P0D0E-73 | Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D0F | Refer to DTC P0D0E-73: Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed [03/2023 - 01/2025] |
| P0D2A-19 | Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Current Above Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D2A |
Refer to DTC P0D2A-19: Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Current Above Threshold [03/2023 - ] |
| P0D38-12 | Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Auxiliary Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D3B |
Refer to DTC P0D38-12: Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Auxiliary Battery; DTC P0D38-14: Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Ground or Open [03/2023 - ] |
| P0D38-14 | Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D3A |
Refer to DTC P0D38-12: Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Auxiliary Battery; DTC P0D38-14: Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Ground or Open [03/2023 - ] |
| P0D38-28 | Hybrid/EV Battery Charger Input Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D39 |
Refer to DTC P0D38-28: Hybrid/EV Battery Charger Input Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0D38-9E | Hybrid/EV Battery Charger Input Current Sensor Overcurrent Detection Circuit Stuck On | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D38 |
Refer to DTC P0D38-9E: Hybrid/EV Battery Charger Input Current Sensor Overcurrent Detection Circuit Stuck On [03/2023 - ] |
| P0D4C-1C | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D4D | Refer to DTC P0D4C-1C: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range [03/2023 - ] |
| P0D4C-36 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Signal Frequency Too Low | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D4E |
Refer to DTC P0D4C-36: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Signal Frequency Too Low [03/2023 - ] |
| P0D4C-37 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Signal Frequency Too High | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D4F |
Refer to DTC P0D4C-37: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Signal Frequency Too High [03/2023 - ] |
| P0D4C-9E | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Stuck On | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D4C |
Refer to DTC P0D4C-9E: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Stuck On [03/2023 - ] |
| P0D51-12 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit High Circuit Short to Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D54 |
Refer to DTC P0D51-12: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit High Circuit Short to Battery; DTC P0D51-14: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Low Circuit Short to Ground or Open [03/2023 - ] |
| P0D51-14 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Low Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D53 |
Refer to DTC P0D51-12: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit High Circuit Short to Battery; DTC P0D51-14: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Low Circuit Short to Ground or Open [03/2023 - ] |
| P0D51-28 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D52 |
Refer to DTC P0D51-28: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0D51-9E | Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Stuck On | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D51 |
Refer to DTC P0D51-9E: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Stuck On [03/2023 - ] |
| P0D56-11 | Charging Connector Proximity Detection Circuit Short to Ground | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D58 |
Refer to DTC P0D56-11: Charging Connector Proximity Detection Circuit Short to Ground [03/2023 - ] |
| P0D56-15 | Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D59 |
Refer to DTC P0D56-15: Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open [03/2023 - ] |
| P0D5C-00 | Charger Input/Output Power Difference High | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D5C |
Refer to DTC P0D5C-00: Charger Input/Output Power Difference High [03/2023 - ] |
| P0D5E-00 | Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D5E | Refer to DTC P0D5E-00: Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long [03/2023 - 01/2025] |
| P0E5E-87 | Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0E5E |
Refer to DTC P0E5E-87: Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message [03/2023 - ] |
| P0E61-9E | Hybrid/EV Battery Charger Enable Circuit Stuck On | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0E64 | Refer to DTC P0E61-9E: Hybrid/EV Battery Charger Enable Circuit Stuck On [03/2023 - ] |
| P0E6A-73 | Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0E6B | Refer to DTC P0E6A-73: Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed [03/2023 - 01/2025] |
| P0EF7-16 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0EF9 |
Refer to DTC P0EF7-16: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold; DTC P0EF7-17: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold [03/2023 - ] |
| P0EF7-17 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0EFA |
Refer to DTC P0EF7-16: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold; DTC P0EF7-17: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold [03/2023 - ] |
| P0EF7-28 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0EF8 |
Refer to DTC P0EF7-28: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0EFB-16 | Hybrid/EV Battery Charger "A" Input Voltage Sensor "C" Circuit Low Circuit Voltage Below Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0EFD |
Refer to DTC P0EFB-16: Hybrid/EV Battery Charger "A" Input Voltage Sensor "C" Circuit Low Circuit Voltage Below Threshold [03/2023 - ] |
| P1661-00 | Battery Charger "A" Inlet-Outlet Switching Contactor Stuck Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1663 |
Refer to DTC P1661-00: Battery Charger "A" Inlet-Outlet Switching Contactor Stuck Open [03/2023 - ] |
| P1661-73 | Battery Charger "A" Inlet-Outlet Switching Contactor Actuator Stuck Closed | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1662 |
Refer to DTC P1661-73: Battery Charger "A" Inlet-Outlet Switching Contactor Actuator Stuck Closed [03/2023 - ] |
| P1684-49 | AC Onboard Charger Module Processor Internal Electronic Failure | Does not come on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1684 |
Refer to DTC P1684-49: AC Onboard Charger Module Processor Internal Electronic Failure [03/2023 - ] |
| P1687-49 | AC Onboard Charger Module A/D Processing Internal Electronic Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1687 |
Refer to DTC P1687-49: AC Onboard Charger Module A/D Processing Internal Electronic Failure [03/2023 - ] |
| P1951-62 | Charger "A" DC/DC Converter Temperature Sensor (for Charging)/Hybrid/EV Output Temperature Sensor Signal Compare Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1951 |
Refer to DTC P1951-62: Charger "A" DC/DC Converter Temperature Sensor (for Charging)/Hybrid/EV Output Temperature Sensor Signal Compare Failure [03/2023 - ] |
| P1958-16 | Charger "A" Power Feeding Output Voltage Sensor Circuit Voltage Below Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P195A |
Refer to DTC P1958-16: Charger "A" Power Feeding Output Voltage Sensor Circuit Voltage Below Threshold [03/2023 - ] |
| P19AF-00 | Charger "A" DC/DC Converter Malfunction (for Power Feeding) | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P19AF |
Refer to DTC P19AF-00: Charger "A" DC/DC Converter Malfunction (for Power Feeding) [03/2023 - ] |
| P19C5-12 | Hybrid/EV Output Temperature Sensor Circuit Short to Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P19C8 |
Refer to DTC P19C5-12: Hybrid/EV Output Temperature Sensor Circuit Short to Battery; DTC P19C5-14: Hybrid/EV Output Temperature Sensor Circuit Short to Ground or Open [03/2023 - ] |
| P19C5-14 | Hybrid/EV Output Temperature Sensor Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P19C7 |
Refer to DTC P19C5-12: Hybrid/EV Output Temperature Sensor Circuit Short to Battery; DTC P19C5-14: Hybrid/EV Output Temperature Sensor Circuit Short to Ground or Open [03/2023 - ] |
| P19CC-19 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Current (ICHG) High Circuit Current Above Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P19CC |
Refer to DTC P19CC-19: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current (ICHG) High Circuit Current Above Threshold [03/2023 - ] |
| P19D0-14 | Hybrid/EV Battery Charger Control Module "A" Sensor Power Supply "A" Circuit Short to Ground or Open | Does not come on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P19D1 |
Refer to DTC P19D0-14: Hybrid/EV Battery Charger Control Module "A" Sensor Power Supply "A" Circuit Short to Ground or Open [03/2023 - ] |
| P1C00-12 | Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Auxiliary Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C03 |
Refer to DTC P1C00-12: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Auxiliary Battery; DTC P1C00-14: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Ground or Open [03/2023 - ] |
| P1C00-14 | Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C02 |
Refer to DTC P1C00-12: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Auxiliary Battery; DTC P1C00-14: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Ground or Open [03/2023 - ] |
| P1C00-16 | Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Voltage Below Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C01 |
Refer to DTC P1C00-16: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Voltage Below Threshold [03/2023 - ] |
| P1C00-9E | Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C00 |
Refer to DTC P1C00-9E: Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On [03/2023 - ] |
| P1C05-12 | PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C08 |
Refer to DTC P1C05-12: PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery; DTC P1C05-14: PFC Inverter Temperature Sensor Circuit Short to Ground or Open [03/2023 - ] |
| P1C05-14 | PFC Inverter Temperature Sensor Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C07 |
Refer to DTC P1C05-12: PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery; DTC P1C05-14: PFC Inverter Temperature Sensor Circuit Short to Ground or Open [03/2023 - ] |
| P1C0A-12 | DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C0D |
Refer to DTC P1C0A-12: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery; DTC P1C0A-14: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open [03/2023 - ] |
| P1C0A-14 | DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C0C |
Refer to DTC P1C0A-12: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery; DTC P1C0A-14: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open [03/2023 - ] |
| P1C1B-00 | PFC Boosting Circuit Malfunction | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D5C |
Refer to DTC P1C1B-00: PFC Boosting Circuit Malfunction [03/2023 - ] |
| P1C1C-00 | DC/DC Converter Malfunction (for Charging) | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D5C |
Refer to DTC P1C1C-00: DC/DC Converter Malfunction (for Charging) [03/2023 - ] |
| P1C1D-00 | Charging Power Low | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D5C |
Refer to DTC P1C1D-00: Charging Power Low [03/2023 - ] |
| P1C1E-00 | Charging Power High | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D5C |
Refer to DTC P1C1E-00: Charging Power High [03/2023 - ] |
| P1C25-62 | PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C25 |
Refer to DTC P1C25-62: PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure [03/2023 - ] |
| P1C26-17 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Voltage Above Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P1C26 |
Refer to DTC P1C26-17: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Voltage Above Threshold [03/2023 - ] |
| P1C27-17 | Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Voltage Above Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C27 |
Refer to DTC P1C27-17: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Voltage Above Threshold [03/2023 - ] |
| P1CA4-00 | Charger Pre-charging Malfunction | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D5C |
Refer to DTC P1CA4-00: Charger Pre-charging Malfunction [03/2023 - ] |
| P1CE9-96 | Charger Cooling Fan Revolution Sensor Component Internal Failure | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P1CEA |
Refer to DTC P1CE9-96: Charger Cooling Fan Revolution Sensor Component Internal Failure [03/2023 - ] |
| P1CED-1C | Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range | Does not come on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1CED |
Refer to DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range [03/2023 - ] |
| P1CF0-1C | Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range | Does not come on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1CF0 |
Refer to DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range [03/2023 - ] |
| P1EA0-9E | Solar Charger Enable Circuit Stuck On | Does not come on | Solar Charging Warning Light: Comes on |
Plug-in Control | B | SAE Code: P1EA3 | Refer to DTC P1EA0-9E: Solar Charger Enable Circuit Stuck On [03/2023 - ] |
| P1EA4-1C | Solar Charging Voltage Sensor Circuit Voltage Out of Range | Does not come on | Solar Charging Warning Light: Comes on |
Plug-in Control | B | SAE Code: P1EA5 | Refer to DTC P1EA4-1C: Solar Charging Voltage Sensor Circuit Voltage Out of Range [03/2023 - ] |
| P1EA9-17 | Solar Charging Control Module Circuit Voltage Above Threshold | Does not come on | Solar Charging Warning Light: Comes on |
Plug-in Control | B | SAE Code: P1EA9 | Refer to DTC P1EA9-17: Solar Charging Control Module Circuit Voltage Above Threshold [03/2023 - ] |
| P308F-49 | High Voltage Charging Circuit Short during Pre-Charge | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P308F | Refer to DTC P308F-49: High Voltage Charging Circuit Short during Pre-Charge [03/2023 - 01/2025] |
| P309F-49 | High Voltage Charging Circuit Consumption Circuit Short | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P309F | Refer to DTC P309F-49: High Voltage Charging Circuit Consumption Circuit Short [03/2023 - 01/2025] |
| U0100-87 | Lost Communication with ECM/PCM "A" Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U0100 |
Refer to DTC U0100-87: Lost Communication with ECM/PCM "A" Missing Message; DTC U0155-87: Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message; DTC U0293-87: Lost Communication with Hybrid/EV Powertrain Control Module Missing Message [03/2023 - ] |
| U0155-87 | Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message | Does not come on | Master Warning: Does not come on |
Plug-in Control | B | SAE Code: U0155 |
Refer to DTC U0100-87: Lost Communication with ECM/PCM "A" Missing Message; DTC U0155-87: Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message; DTC U0293-87: Lost Communication with Hybrid/EV Powertrain Control Module Missing Message [03/2023 - ] |
| U01BB-87 | Lost Communication with Battery Charger Control Module "B" Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U01BB | Refer to DTC U01BB-87: Lost Communication with Battery Charger Control Module "B" Missing Message [03/2023 - ] |
| U0293-87 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U0293 |
Refer to DTC U0100-87: Lost Communication with ECM/PCM "A" Missing Message; DTC U0155-87: Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message; DTC U0293-87: Lost Communication with Hybrid/EV Powertrain Control Module Missing Message [03/2023 - ] |
| U113A-87 | Lost Communication with Solar Charging Control Module Missing Message | Does not come on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U113A |
Refer to DTC U113A-87: Lost Communication with Solar Charging Control Module Missing Message [03/2023 - ] |
| U1151-87 | Lost Communication with Hybrid/EV Powertrain Control Module (ch3) Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U1151 |
Refer to DTC U1151-87: Lost Communication with Hybrid/EV Powertrain Control Module (ch3) Missing Message [03/2023 - ] |
| U117B-87 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" (ch2) Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U117B |
Refer to DTC U117B-87: Lost Communication with Hybrid/EV Battery Energy Control Module "A" (ch2) Missing Message [03/2023 - ] |