| P0335-06 |
Crankshaft Position Sensor "A" Algorithm Based Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0336 |
Refer to DTC P0335-06: Crankshaft Position Sensor "A" Algorithm Based Failure; DTC P0335-62: Crankshaft Position Sensor "A" Signal Compare Failure [03/2023 - ] |
| P0335-16 |
Crankshaft Position Sensor "A" Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0337 |
Refer to DTC P0335-16: Crankshaft Position Sensor "A" Circuit Voltage Below Threshold; DTC P0335-17: Crankshaft Position Sensor "A" Circuit Voltage Above Threshold; DTC P0335-23: Crankshaft Position Sensor "A" Signal Stuck Low; DTC P0335-24: Crankshaft Position Sensor "A" Signal Stuck High [03/2023 - ] |
| P0335-17 |
Crankshaft Position Sensor "A" Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0338 |
Refer to DTC P0335-16: Crankshaft Position Sensor "A" Circuit Voltage Below Threshold; DTC P0335-17: Crankshaft Position Sensor "A" Circuit Voltage Above Threshold; DTC P0335-23: Crankshaft Position Sensor "A" Signal Stuck Low; DTC P0335-24: Crankshaft Position Sensor "A" Signal Stuck High [03/2023 - ] |
| P0335-23 |
Crankshaft Position Sensor "A" Signal Stuck Low |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0337 |
Refer to DTC P0335-16: Crankshaft Position Sensor "A" Circuit Voltage Below Threshold; DTC P0335-17: Crankshaft Position Sensor "A" Circuit Voltage Above Threshold; DTC P0335-23: Crankshaft Position Sensor "A" Signal Stuck Low; DTC P0335-24: Crankshaft Position Sensor "A" Signal Stuck High [03/2023 - ] |
| P0335-24 |
Crankshaft Position Sensor "A" Signal Stuck High |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0338 |
Refer to DTC P0335-16: Crankshaft Position Sensor "A" Circuit Voltage Below Threshold; DTC P0335-17: Crankshaft Position Sensor "A" Circuit Voltage Above Threshold; DTC P0335-23: Crankshaft Position Sensor "A" Signal Stuck Low; DTC P0335-24: Crankshaft Position Sensor "A" Signal Stuck High [03/2023 - ] |
| P0335-62 |
Crankshaft Position Sensor "A" Signal Compare Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0336 |
Refer to DTC P0335-06: Crankshaft Position Sensor "A" Algorithm Based Failure; DTC P0335-62: Crankshaft Position Sensor "A" Signal Compare Failure [03/2023 - ] |
| P0340-06 |
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Algorithm Based Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0341 |
Refer to DTC P0340-06: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Algorithm Based Failure; DTC P0340-62: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Compare Failure [03/2023 - ] |
| P0340-16 |
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0342 |
Refer to DTC P0340-16: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Below Threshold; DTC P0340-17: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Above Threshold; DTC P0340-23: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck Low; DTC P0340-24: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck High [03/2023 - ] |
| P0340-17 |
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0343 |
Refer to DTC P0340-16: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Below Threshold; DTC P0340-17: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Above Threshold; DTC P0340-23: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck Low; DTC P0340-24: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck High [03/2023 - ] |
| P0340-23 |
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck Low |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0342 |
Refer to DTC P0340-16: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Below Threshold; DTC P0340-17: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Above Threshold; DTC P0340-23: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck Low; DTC P0340-24: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck High [03/2023 - ] |
| P0340-24 |
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck High |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0343 |
Refer to DTC P0340-16: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Below Threshold; DTC P0340-17: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Circuit Voltage Above Threshold; DTC P0340-23: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck Low; DTC P0340-24: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Stuck High [03/2023 - ] |
| P0340-62 |
Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Compare Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0341 |
Refer to DTC P0340-06: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Algorithm Based Failure; DTC P0340-62: Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor Signal Compare Failure [03/2023 - ] |
| P062F-44 |
Internal Control Module EEPROM Data Memory Failure |
Comes on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P062F |
Refer to DTC P062F-44: Internal Control Module EEPROM Data Memory Failure [03/2023 - ] |
| P062F-46 |
Generator Control Module (EEPROM Learning Value) Calibration / Parameter Memory Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P062F |
Refer to DTC P062F-46: Generator Control Module (EEPROM Learning Value) Calibration / Parameter Memory Failure [03/2023 - ] |
| P06B0-1C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P06B0 |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P06D6-1C |
Generator Control Module Offset Power Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P06D6 |
Refer to DTC P06D6-1C: Generator Control Module Offset Power Circuit Voltage Out of Range [03/2023 - ] |
| P0A00-11 |
Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A02 |
Refer to DTC P0A00-11: Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; DTC P0A00-15: Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open [03/2023 - ] |
| P0A00-15 |
Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A03 |
Refer to DTC P0A00-11: Motor Electronics Coolant Temperature Sensor Circuit Short to Ground; DTC P0A00-15: Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open [03/2023 - ] |
| P0A00-1C |
Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A01 |
Refer to DTC P0A00-1C: Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range [03/2023 - ] |
| P0A1A-47 |
Generator Control Module Watchdog / Safety MC Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A1A |
Refer to DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A1A-47: Generator Control Module Watchdog / Safety MC Failure; DTC P0A4B-22: Generator Position Sensor Signal Amplitude > Maximum; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure [03/2023 - ] |
| P0A1A-49 |
Generator Control Module Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A1A |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P0A1B-1F |
Generator Control Module Circuit Intermittent |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A1B |
Refer to DTC P0A1B-1F: Generator Control Module Circuit Intermittent [03/2023 - ] |
| P0A1B-47 |
Drive Motor "A" Control Module Watchdog / Safety MC Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A1B |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P0A1B-49 |
Drive Motor "A" Control Module Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A1B |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P0A1B-94 |
Drive Motor "A" Control Module Unexpected Operation |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A1B |
Refer to DTC P0A1B-94: Drive Motor "A" Control Module Unexpected Operation [03/2023 - ] |
| P0A2A-11 |
Drive Motor "A" Temperature Sensor Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A2C |
Refer to DTC P0A2A-11: Drive Motor "A" Temperature Sensor Circuit Short to Ground; DTC P0A2A-15: Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open [03/2023 - ] |
| P0A2A-15 |
Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A2D |
Refer to DTC P0A2A-11: Drive Motor "A" Temperature Sensor Circuit Short to Ground; DTC P0A2A-15: Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open [03/2023 - ] |
| P0A2A-1C |
Drive Motor "A" Temperature Sensor Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A2B |
Refer to DTC P0A2A-1C: Drive Motor "A" Temperature Sensor Voltage Out of Range; DTC P0A2A-1F: Drive Motor "A" Temperature Sensor Circuit Intermittent [03/2023 - ] |
| P0A2A-1F |
Drive Motor "A" Temperature Sensor Circuit Intermittent |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A2E |
Refer to DTC P0A2A-1C: Drive Motor "A" Temperature Sensor Voltage Out of Range; DTC P0A2A-1F: Drive Motor "A" Temperature Sensor Circuit Intermittent [03/2023 - ] |
| P0A36-11 |
Generator Temperature Sensor Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A38 |
Refer to DTC P0A36-11: Generator Temperature Sensor Circuit Short to Ground; DTC P0A36-15: Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open [03/2023 - ] |
| P0A36-15 |
Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A39 |
Refer to DTC P0A36-11: Generator Temperature Sensor Circuit Short to Ground; DTC P0A36-15: Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open [03/2023 - ] |
| P0A36-1C |
Generator Temperature Sensor Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A37 |
Refer to DTC P0A36-1C: Generator Temperature Sensor Voltage Out of Range; DTC P0A36-1F: Generator Temperature Sensor Circuit Intermittent [03/2023 - ] |
| P0A36-1F |
Generator Temperature Sensor Circuit Intermittent |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A3A |
Refer to DTC P0A36-1C: Generator Temperature Sensor Voltage Out of Range; DTC P0A36-1F: Generator Temperature Sensor Circuit Intermittent [03/2023 - ] |
| P0A3F-16 |
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A3F |
Refer to DTC P0A3F-16: Drive Motor "A" Position Sensor Circuit Voltage Below Threshold; DTC P0A3F-1F: Drive Motor "A" Position Sensor Circuit Intermittent [03/2023 - ] |
| P0A3F-1F |
Drive Motor "A" Position Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P0A43 |
Refer to DTC P0A3F-16: Drive Motor "A" Position Sensor Circuit Voltage Below Threshold; DTC P0A3F-1F: Drive Motor "A" Position Sensor Circuit Intermittent [03/2023 - ] |
| P0A3F-21 |
Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A41 |
Refer to DTC P0A3F-21: Drive Motor "A" Position Sensor Signal Amplitude < Minimum; DTC P0A3F-22: Drive Motor "A" Position Sensor Signal Amplitude > Maximum [03/2023 - ] |
| P0A3F-22 |
Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A42 |
Refer to DTC P0A3F-21: Drive Motor "A" Position Sensor Signal Amplitude < Minimum; DTC P0A3F-22: Drive Motor "A" Position Sensor Signal Amplitude > Maximum [03/2023 - ] |
| P0A4B-16 |
Generator Position Sensor Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A4B |
Refer to DTC P0A4B-16: Generator Position Sensor Circuit Voltage Below Threshold; DTC P0A4B-1F: Generator Position Sensor Circuit Intermittent [03/2023 - ] |
| P0A4B-1F |
Generator Position Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P0A4F |
Refer to DTC P0A4B-16: Generator Position Sensor Circuit Voltage Below Threshold; DTC P0A4B-1F: Generator Position Sensor Circuit Intermittent [03/2023 - ] |
| P0A4B-21 |
Generator Position Sensor Signal Amplitude < Minimum |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A4D |
Refer to DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A1A-47: Generator Control Module Watchdog / Safety MC Failure; DTC P0A4B-22: Generator Position Sensor Signal Amplitude > Maximum; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure [03/2023 - ] |
| P0A4B-22 |
Generator Position Sensor Signal Amplitude > Maximum |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A4E |
Refer to DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A1A-47: Generator Control Module Watchdog / Safety MC Failure; DTC P0A4B-22: Generator Position Sensor Signal Amplitude > Maximum; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure [03/2023 - ] |
| P0A60-12 |
Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery |
Does not come on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A62 |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [03/2023 - ] |
| P0A60-14 |
Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A61 |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [03/2023 - ] |
| P0A60-1C |
Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range |
Does not come on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1C32 |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [03/2023 - ] |
| P0A60-1F |
Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C33 |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [03/2023 - ] |
| P0A63-12 |
Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery |
Does not come on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A65 |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [03/2023 - ] |
| P0A63-14 |
Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open |
Does not come on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A64 |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [03/2023 - ] |
| P0A63-1C |
Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range |
Does not come on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1C34 |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [03/2023 - ] |
| P0A63-1F |
Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C35 |
Refer to DTC P0A60-12: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery; DTC P0A60-14: Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open; DTC P0A60-1C: Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range; DTC P0A60-1F: Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent; DTC P0A63-12: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery; DTC P0A63-14: Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open; DTC P0A63-1C: Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range; DTC P0A63-1F: Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent [03/2023 - ] |
| P0A78-72 |
Drive Motor "A" Inverter Actuator Stuck Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A78 |
Refer to DTC P0A78-72: Drive Motor "A" Inverter Actuator Stuck Open [03/2023 - ] |
| P0A78-73 |
Drive Motor "A" Inverter Actuator Stuck Closed |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A78 |
Refer to DTC P0A78-73: Drive Motor "A" Inverter Actuator Stuck Closed [03/2023 - ] |
| P0A78-9E |
Drive Motor "A" Inverter Stuck On |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A78 |
Refer to DTC P0A78-9E: Drive Motor "A" Inverter Stuck On; DTC P1C5D-19: Drive Motor "A" Inverter Circuit Current Above Threshold [03/2023 - ] |
| P0A7A-72 |
Generator Inverter Actuator Stuck Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A7A |
Refer to DTC P0A7A-72: Generator Inverter Actuator Stuck Open [03/2023 - ] |
| P0A7A-73 |
Generator Inverter Actuator Stuck Closed |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A7A |
Refer to DTC P0A7A-73: Generator Inverter Actuator Stuck Closed [03/2023 - ] |
| P0A7A-9E |
Generator Inverter Stuck On |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A7A |
Refer to DTC P0A7A-9E: Generator Inverter Stuck On; DTC P1C5F-19: Generator Inverter Circuit Current Above Threshold [03/2023 - ] |
| P0A90-00 |
Drive Motor "A" Performance |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A90 |
Refer to DTC P0A90-00: Drive Motor "A" Performance [03/2023 - ] |
| P0A92-00 |
Hybrid/EV Generator Performance |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A92 |
Refer to DTC P0A92-00: Hybrid/EV Generator Performance [03/2023 - ] |
| P0A94-9E |
DC/DC Converter Stuck On |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A94 |
Refer to DTC P0A94-9E: DC/DC Converter Stuck On; DTC P0D33-19: DC/DC Converter Circuit Current Above Threshold [03/2023 - ] |
| P0AED-11 |
Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0AEF |
Refer to DTC P0AED-11: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground; DTC P0AED-15: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open [03/2023 - ] |
| P0AED-15 |
Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0AF0 |
Refer to DTC P0AED-11: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground; DTC P0AED-15: Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open [03/2023 - ] |
| P0AED-1C |
Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0AEE |
Refer to DTC P0AED-1C: Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range [03/2023 - ] |
| P0BCC-11 |
Generator Inverter Temperature Sensor Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BCE |
Refer to DTC P0BCC-11: Generator Inverter Temperature Sensor Circuit Short to Ground; DTC P0BCC-15: Generator Inverter Temperature Sensor Circuit Short to Battery or Open [03/2023 - ] |
| P0BCC-15 |
Generator Inverter Temperature Sensor Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BCF |
Refer to DTC P0BCC-11: Generator Inverter Temperature Sensor Circuit Short to Ground; DTC P0BCC-15: Generator Inverter Temperature Sensor Circuit Short to Battery or Open [03/2023 - ] |
| P0BCC-1C |
Generator Inverter Temperature Sensor Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BCD |
Refer to DTC P0BCC-1C: Generator Inverter Temperature Sensor Circuit Voltage Out of Range [03/2023 - ] |
| P0BE5-12 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BE8 |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0BE5-14 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BE7 |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0BE5-1F |
Drive Motor "A" Phase U Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C40 |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0BE5-28 |
Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BE6 |
Refer to DTC P0BE5-28: Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BE9-28: Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BED-28: Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" [03/2023 - ] |
| P0BE9-12 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BEC |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0BE9-14 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BEB |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0BE9-1F |
Drive Motor "A" Phase V Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C41 |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0BE9-28 |
Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BEA |
Refer to DTC P0BE5-28: Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BE9-28: Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BED-28: Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" [03/2023 - ] |
| P0BED-12 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BF0 |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0BED-14 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BEF |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0BED-1F |
Drive Motor "A" Phase W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C42 |
Refer to DTC P0BE5-12: Drive Motor "A" Phase U Current Sensor Circuit Short to Battery; DTC P0BE5-14: Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open; DTC P0BE5-1F: Drive Motor "A" Phase U Current Sensor Circuit Intermittent; DTC P0BE9-12: Drive Motor "A" Phase V Current Sensor Circuit Short to Battery; DTC P0BE9-14: Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open; DTC P0BE9-1F: Drive Motor "A" Phase V Current Sensor Circuit Intermittent; DTC P0BED-12: Drive Motor "A" Phase W Current Sensor Circuit Short to Battery; DTC P0BED-14: Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open; DTC P0BED-1F: Drive Motor "A" Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0BED-28 |
Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BEE |
Refer to DTC P0BE5-28: Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BE9-28: Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"; DTC P0BED-28: Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure" [03/2023 - ] |
| P0BFD-62 |
Drive Motor A" Phase U-V-W Current Sensor Signal Compare Failure" |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BFD |
Refer to DTC P0BFD-62: Drive Motor A" Phase U-V-W Current Sensor Signal Compare Failure"; DTC P1C67-1F: Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0BFF-1D |
Drive Motor "A" Circuit Current Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0BFF |
Refer to DTC P0BFF-1D: Drive Motor "A" Circuit Current Out of Range [03/2023 - ] |
| P0C19-00 |
Drive Motor "A" Execution Torque Performance |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C19 |
Refer to DTC P0C19-00: Drive Motor "A" Execution Torque Performance [03/2023 - ] |
| P0C38-11 |
DC/DC Converter Temperature Sensor "A" Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C3A |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [03/2023 - ] |
| P0C38-15 |
DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C3B |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [03/2023 - ] |
| P0C38-1C |
DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C39 |
Refer to DTC P0C38-1C: DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range [03/2023 - ] |
| P0C3D-11 |
DC/DC Converter Temperature Sensor "B" Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C3F |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [03/2023 - ] |
| P0C3D-15 |
DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C40 |
Refer to DTC P0C38-11: DC/DC Converter Temperature Sensor "A" Circuit Short to Ground; DTC P0C38-15: DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open; DTC P0C3D-11: DC/DC Converter Temperature Sensor "B" Circuit Short to Ground; DTC P0C3D-15: DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open [03/2023 - ] |
| P0C3D-1C |
DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C3E |
Refer to DTC P0C3D-1C: DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range [03/2023 - ] |
| P0C50-13 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C50 |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [03/2023 - ] |
| P0C50-16 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C52 |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [03/2023 - ] |
| P0C50-17 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C53 |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [03/2023 - ] |
| P0C50-1F |
Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P0C54 |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [03/2023 - ] |
| P0C5A-13 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C5A |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [03/2023 - ] |
| P0C5A-16 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C5C |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [03/2023 - ] |
| P0C5A-17 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C5D |
Refer to DTC P0C50-16: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C50-17: Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C5A-16: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C5A-17: Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold [03/2023 - ] |
| P0C5A-1F |
Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P0C5E |
Refer to DTC P0C50-13: Drive Motor "A" Position Sensor Circuit "A" Circuit Open; DTC P0C50-1F: Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent; DTC P0C5A-13: Drive Motor "A" Position Sensor Circuit "B" Circuit Open; DTC P0C5A-1F: Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent [03/2023 - ] |
| P0C64-13 |
Generator Position Sensor Circuit "A" Circuit Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C64 |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [03/2023 - ] |
| P0C64-16 |
Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C66 |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [03/2023 - ] |
| P0C64-17 |
Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C67 |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [03/2023 - ] |
| P0C64-1F |
Generator Position Sensor Circuit "A" Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P0C68 |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [03/2023 - ] |
| P0C69-13 |
Generator Position Sensor Circuit "B" Circuit Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C69 |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [03/2023 - ] |
| P0C69-16 |
Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C6B |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [03/2023 - ] |
| P0C69-17 |
Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C6C |
Refer to DTC P0C64-16: Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold; DTC P0C64-17: Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold; DTC P0C69-16: Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold; DTC P0C69-17: Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold [03/2023 - ] |
| P0C69-1F |
Generator Position Sensor Circuit "B" Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P0C6D |
Refer to DTC P0C64-13: Generator Position Sensor Circuit "A" Circuit Open; DTC P0C64-1F: Generator Position Sensor Circuit "A" Circuit Intermittent; DTC P0C69-13: Generator Position Sensor Circuit "B" Circuit Open; DTC P0C69-1F: Generator Position Sensor Circuit "B" Circuit Intermittent [03/2023 - ] |
| P0C79-17 |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0C79 |
Refer to DTC P0C79-17: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold [03/2023 - ] |
| P0CA3-00 |
DC/DC Converter Step Up Voltage Performance |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0CA3 |
Refer to DTC P0CA3-00: DC/DC Converter Step Up Voltage Performance [03/2023 - ] |
| P0D2D-16 |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0D2F |
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold; DTC P0D2D-17: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold; DTC P0D2D-1F: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent [03/2023 - ] |
| P0D2D-17 |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0D30 |
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold; DTC P0D2D-17: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold; DTC P0D2D-1F: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent [03/2023 - ] |
| P0D2D-1F |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P0D31 |
Refer to DTC P0D2D-16: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold; DTC P0D2D-17: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold; DTC P0D2D-1F: Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent [03/2023 - ] |
| P0D33-19 |
DC/DC Converter Circuit Current Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0D33 |
Refer to DTC P0A94-9E: DC/DC Converter Stuck On; DTC P0D33-19: DC/DC Converter Circuit Current Above Threshold [03/2023 - ] |
| P0DFA-62 |
Generator Phase U-V-W Current Sensor Signal Compare Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0DFA |
Refer to DTC P0DFA-62: Generator Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C69-1F: Generator Phase U-V-W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E00-12 |
Generator Phase U Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E03 |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E00-14 |
Generator Phase U Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E02 |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E00-1F |
Generator Phase U Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C46 |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E00-28 |
Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E01 |
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E04-28: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E08-28: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0E04-12 |
Generator Phase V Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E07 |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E04-14 |
Generator Phase V Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E06 |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E04-1F |
Generator Phase V Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C47 |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E04-28 |
Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E05 |
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E04-28: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E08-28: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0E08-12 |
Generator Phase W Current Sensor Circuit Short to Battery |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E0B |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E08-14 |
Generator Phase W Current Sensor Circuit Short to Ground or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E0A |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E08-1F |
Generator Phase W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C48 |
Refer to DTC P0E00-12: Generator Phase U Current Sensor Circuit Short to Battery; DTC P0E00-14: Generator Phase U Current Sensor Circuit Short to Ground or Open; DTC P0E00-1F: Generator Phase U Current Sensor Circuit Intermittent; DTC P0E04-12: Generator Phase V Current Sensor Circuit Short to Battery; DTC P0E04-14: Generator Phase V Current Sensor Circuit Short to Ground or Open; DTC P0E04-1F: Generator Phase V Current Sensor Circuit Intermittent; DTC P0E08-12: Generator Phase W Current Sensor Circuit Short to Battery; DTC P0E08-14: Generator Phase W Current Sensor Circuit Short to Ground or Open; DTC P0E08-1F: Generator Phase W Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E08-28 |
Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E09 |
Refer to DTC P0E00-28: Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E04-28: Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure; DTC P0E08-28: Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0E31-16 |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E33 |
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E31-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E31-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [03/2023 - ] |
| P0E31-17 |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E34 |
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E31-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E31-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [03/2023 - ] |
| P0E31-1F |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P0E35 |
Refer to DTC P0E31-16: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold; DTC P0E31-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold; DTC P0E31-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [03/2023 - ] |
| P0E51-11 |
DC/DC Converter Current Sensor Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E53 |
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E51-15: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E51-1F: DC/DC Converter Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E51-15 |
DC/DC Converter Current Sensor Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E54 |
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E51-15: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E51-1F: DC/DC Converter Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E51-1F |
DC/DC Converter Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P0E55 |
Refer to DTC P0E51-11: DC/DC Converter Current Sensor Circuit Short to Ground; DTC P0E51-15: DC/DC Converter Current Sensor Circuit Short to Battery or Open; DTC P0E51-1F: DC/DC Converter Current Sensor Circuit Intermittent [03/2023 - ] |
| P0E51-28 |
DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E52 |
Refer to DTC P0E51-28: DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0E57-17 |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E57 |
Refer to DTC P0E57-17: DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold [03/2023 - ] |
| P0E71-00 |
Generator Execution Torque Performance |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E71 |
Refer to DTC P0E71-00: Generator Execution Torque Performance [03/2023 - ] |
| P0E9B-11 |
DC/DC Converter Current Sensor "B" Circuit Low Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E9D |
Refer to DTC P0E9B-11: DC/DC Converter Current Sensor "B" Circuit Low Circuit Short to Ground; DTC P0E9B-15: DC/DC Converter Current Sensor "B" Circuit High Circuit Short to Battery or Open; DTC P0E9B-1F: DC/DC Converter Current Sensor "B" Circuit Intermittent/Erratic Circuit Intermittent [03/2023 - ] |
| P0E9B-15 |
DC/DC Converter Current Sensor "B" Circuit High Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E9E |
Refer to DTC P0E9B-11: DC/DC Converter Current Sensor "B" Circuit Low Circuit Short to Ground; DTC P0E9B-15: DC/DC Converter Current Sensor "B" Circuit High Circuit Short to Battery or Open; DTC P0E9B-1F: DC/DC Converter Current Sensor "B" Circuit Intermittent/Erratic Circuit Intermittent [03/2023 - ] |
| P0E9B-1F |
DC/DC Converter Current Sensor "B" Circuit Intermittent/Erratic Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P0E9F |
Refer to DTC P0E9B-11: DC/DC Converter Current Sensor "B" Circuit Low Circuit Short to Ground; DTC P0E9B-15: DC/DC Converter Current Sensor "B" Circuit High Circuit Short to Battery or Open; DTC P0E9B-1F: DC/DC Converter Current Sensor "B" Circuit Intermittent/Erratic Circuit Intermittent [03/2023 - ] |
| P0E9B-28 |
DC/DC Converter Current Sensor "B" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0E9C |
Refer to DTC P0E9B-28: DC/DC Converter Current Sensor "B" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0EA0-11 |
DC/DC Converter Current Sensor "C" Circuit Low Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0EA2 |
Refer to DTC P0EA0-11: DC/DC Converter Current Sensor "C" Circuit Low Circuit Short to Ground; DTC P0EA0-15: DC/DC Converter Current Sensor "C" Circuit High Circuit Short to Battery or Open [03/2023 - ] |
| P0EA0-15 |
DC/DC Converter Current Sensor "C" Circuit High Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0EA3 |
Refer to DTC P0EA0-11: DC/DC Converter Current Sensor "C" Circuit Low Circuit Short to Ground; DTC P0EA0-15: DC/DC Converter Current Sensor "C" Circuit High Circuit Short to Battery or Open [03/2023 - ] |
| P0EA0-28 |
DC/DC Converter Current Sensor "C" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0EA1 |
Refer to DTC P0EA0-28: DC/DC Converter Current Sensor "C" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0EA5-9E |
DC/DC Converter "B" Stuck On |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0EA5 |
Refer to DTC P0EA5-9E: DC/DC Converter "B" Stuck On; DTC P1F2F-19: DC/DC Converter "B" Circuit Current Above Threshold [03/2023 - ] |
| P19F8-1C |
Generator Control Module Offset Power Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P19F8 |
Refer to DTC P19F8-1C: Generator Control Module Offset Power Circuit Voltage Out of Range [03/2023 - ] |
| P1C2A-1C |
Generator A/D Converter Circuit - Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1C2A |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P1C2A-49 |
Generator A/D Converter Circuit Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1C2A |
Refer to DTC P0A4B-21: Generator Position Sensor Signal Amplitude < Minimum; DTC P0A1A-47: Generator Control Module Watchdog / Safety MC Failure; DTC P0A4B-22: Generator Position Sensor Signal Amplitude > Maximum; DTC P1C2A-49: Generator A/D Converter Circuit Internal Electronic Failure [03/2023 - ] |
| P1C2A-71 |
Generator A/D Converter Circuit Actuator Stuck |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1C2A |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P1C2B-1C |
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1C2B |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P1C2B-49 |
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1C2B |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P1C2B-71 |
Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1C2B |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P1C5D-19 |
Drive Motor "A" Inverter Circuit Current Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1C5D |
Refer to DTC P0A78-9E: Drive Motor "A" Inverter Stuck On; DTC P1C5D-19: Drive Motor "A" Inverter Circuit Current Above Threshold [03/2023 - ] |
| P1C5F-19 |
Generator Inverter Circuit Current Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1C5F |
Refer to DTC P0A7A-9E: Generator Inverter Stuck On; DTC P1C5F-19: Generator Inverter Circuit Current Above Threshold [03/2023 - ] |
| P1C60-1F |
Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C60 |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P1C62-1F |
Generator Control Module Offset Power Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C62 |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P1C64-1F |
Generator Control Module Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C64 |
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C64-1F: Generator Control Module Circuit Intermittent; DTC P1CAF-38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [03/2023 - ] |
| P1C65-1F |
Generator Control Module Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C65 |
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C65-1F: Generator Control Module Circuit Intermittent; DTC P1CB0-38: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [03/2023 - ] |
| P1C67-1F |
Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C67 |
Refer to DTC P0BFD-62: Drive Motor A" Phase U-V-W Current Sensor Signal Compare Failure"; DTC P1C67-1F: Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent [03/2023 - ] |
| P1C69-1F |
Generator Phase U-V-W Current Sensor Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P1C69 |
Refer to DTC P0DFA-62: Generator Phase U-V-W Current Sensor Signal Compare Failure; DTC P1C69-1F: Generator Phase U-V-W Current Sensor Circuit Intermittent [03/2023 - ] |
| P1CA5-1D |
Hybrid/EV Generator Circuit Current Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1CA5 |
Refer to DTC P1CA5-1D: Hybrid/EV Generator Circuit Current Out of Range [03/2023 - ] |
| P1CAC-49 |
Generator Position Sensor Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1CAC |
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C64-1F: Generator Control Module Circuit Intermittent; DTC P1CAF-38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [03/2023 - ] |
| P1CAD-49 |
Drive Motor "A" Position Sensor Internal Electronic Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1CAD |
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C65-1F: Generator Control Module Circuit Intermittent; DTC P1CB0-38: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [03/2023 - ] |
| P1CAF-38 |
Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1CAF |
Refer to DTC P1CAC-49: Generator Position Sensor Internal Electronic Failure; DTC P1C64-1F: Generator Control Module Circuit Intermittent; DTC P1CAF-38: Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect [03/2023 - ] |
| P1CB0-38 |
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1CB0 |
Refer to DTC P1CAD-49: Drive Motor "A" Position Sensor Internal Electronic Failure; DTC P1C65-1F: Generator Control Module Circuit Intermittent; DTC P1CB0-38: Drive Motor "A" Position Sensor REF Signal Frequency Incorrect [03/2023 - ] |
| P1CB5-9E |
DC/DC Converter Voltage Sensor "A"(VL) Stuck On |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A94 |
Refer to DTC P1CB5-9E: DC/DC Converter Voltage Sensor "A"(VL) Stuck On [03/2023 - ] |
| P1CB6-9E |
Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P0A78 |
Refer to DTC P1CB6-9E: Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On [03/2023 - ] |
| P1F2F-19 |
DC/DC Converter "B" Circuit Current Above Threshold |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1F2F |
Refer to DTC P0EA5-9E: DC/DC Converter "B" Stuck On; DTC P1F2F-19: DC/DC Converter "B" Circuit Current Above Threshold [03/2023 - ] |
| P1F70-11 |
DC/DC Converter Current Sensor "D" Circuit Low Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1F72 |
Refer to DTC P1F70-11: DC/DC Converter Current Sensor "D" Circuit Low Circuit Short to Ground; DTC P1F70-15: DC/DC Converter Current Sensor "D" Circuit High Circuit Short to Battery or Open [03/2023 - ] |
| P1F70-15 |
DC/DC Converter Current Sensor "D" Circuit High Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1F73 |
Refer to DTC P1F70-11: DC/DC Converter Current Sensor "D" Circuit Low Circuit Short to Ground; DTC P1F70-15: DC/DC Converter Current Sensor "D" Circuit High Circuit Short to Battery or Open [03/2023 - ] |
| P1F70-28 |
DC/DC Converter Current Sensor "D" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1F71 |
Refer to DTC P1F70-28: DC/DC Converter Current Sensor "D" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P1F75-62 |
DC/DC Converter Current Sensor A/C Correlation Signal Compare Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1F75 |
Refer to DTC P1F75-62: DC/DC Converter Current Sensor A/C Correlation Signal Compare Failure [03/2023 - ] |
| P1F76-62 |
DC/DC Converter Current Sensor B/D Correlation Signal Compare Failure |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P1F76 |
Refer to DTC P1F76-62: DC/DC Converter Current Sensor B/D Correlation Signal Compare Failure [03/2023 - ] |
| P26DF-1C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P26DF |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P26DF-1F |
Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P19F7 |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P274A-11 |
Transmission Fluid Temperature Sensor "C" Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P274C |
Refer to DTC P274A-11: Transmission Fluid Temperature Sensor "C" Circuit Short to Ground; DTC P274A-15: Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open [03/2023 - ] |
| P274A-15 |
Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P274D |
Refer to DTC P274A-11: Transmission Fluid Temperature Sensor "C" Circuit Short to Ground; DTC P274A-15: Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open [03/2023 - ] |
| P274A-1C |
Transmission Fluid Temperature Sensor "C" Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P274B |
Refer to DTC P274A-1C: Transmission Fluid Temperature Sensor "C" Voltage Out of Range; DTC P274A-1F: Transmission Fluid Temperature Sensor "C" Circuit Intermittent [03/2023 - ] |
| P274A-1F |
Transmission Fluid Temperature Sensor "C" Circuit Intermittent |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P274E |
Refer to DTC P274A-1C: Transmission Fluid Temperature Sensor "C" Voltage Out of Range; DTC P274A-1F: Transmission Fluid Temperature Sensor "C" Circuit Intermittent [03/2023 - ] |
| P2C8C-11 |
DC/DC Converter Temperature Sensor "D" Circuit Low Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P2C8E |
Refer to DTC P2C8C-11: DC/DC Converter Temperature Sensor "D" Circuit Low Circuit Short to Ground; DTC P2C8C-15: DC/DC Converter Temperature Sensor "D" Circuit High Circuit Short to Battery or Open; DTC P2CA5-11: DC/DC Converter Temperature Sensor "E" Circuit Low Circuit Short to Ground; DTC P2CA5-15: DC/DC Converter Temperature Sensor "E" Circuit High Circuit Short to Battery or Open [03/2023 - ] |
| P2C8C-15 |
DC/DC Converter Temperature Sensor "D" Circuit High Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P2C8F |
Refer to DTC P2C8C-11: DC/DC Converter Temperature Sensor "D" Circuit Low Circuit Short to Ground; DTC P2C8C-15: DC/DC Converter Temperature Sensor "D" Circuit High Circuit Short to Battery or Open; DTC P2CA5-11: DC/DC Converter Temperature Sensor "E" Circuit Low Circuit Short to Ground; DTC P2CA5-15: DC/DC Converter Temperature Sensor "E" Circuit High Circuit Short to Battery or Open [03/2023 - ] |
| P2C8C-1C |
DC/DC Converter Temperature Sensor "D" Circuit Range/Performance Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P2C8D |
Refer to DTC P2C8C-1C: DC/DC Converter Temperature Sensor "D" Circuit Range/Performance Circuit Voltage Out of Range [03/2023 - ] |
| P2CA5-11 |
DC/DC Converter Temperature Sensor "E" Circuit Low Circuit Short to Ground |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P2CA6 |
Refer to DTC P2C8C-11: DC/DC Converter Temperature Sensor "D" Circuit Low Circuit Short to Ground; DTC P2C8C-15: DC/DC Converter Temperature Sensor "D" Circuit High Circuit Short to Battery or Open; DTC P2CA5-11: DC/DC Converter Temperature Sensor "E" Circuit Low Circuit Short to Ground; DTC P2CA5-15: DC/DC Converter Temperature Sensor "E" Circuit High Circuit Short to Battery or Open [03/2023 - ] |
| P2CA5-15 |
DC/DC Converter Temperature Sensor "E" Circuit High Circuit Short to Battery or Open |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P2CA7 |
Refer to DTC P2C8C-11: DC/DC Converter Temperature Sensor "D" Circuit Low Circuit Short to Ground; DTC P2C8C-15: DC/DC Converter Temperature Sensor "D" Circuit High Circuit Short to Battery or Open; DTC P2CA5-11: DC/DC Converter Temperature Sensor "E" Circuit Low Circuit Short to Ground; DTC P2CA5-15: DC/DC Converter Temperature Sensor "E" Circuit High Circuit Short to Battery or Open [03/2023 - ] |
| P2CA5-1C |
DC/DC Converter Temperature Sensor "E" Circuit Range/Performance Circuit Voltage Out of Range |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P2CA8 |
Refer to DTC P2CA5-1C: DC/DC Converter Temperature Sensor "E" Circuit Range/Performance Circuit Voltage Out of Range [03/2023 - ] |
| P3124-1F |
Lost Communication between Drive Motor "A" and HV/EV ECU Circuit Intermittent |
Does not come on |
Master Warning: Does not come on |
Motor Generator |
A |
SAE Code: P3124 |
Refer to DTC P3124-1F: Lost Communication between Drive Motor "A" and HV/EV ECU Circuit Intermittent [03/2023 - ] |
| P3133-83 |
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P3133 |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P3133-86 |
Communication Error from Generator to Drive Motor "A" Signal Invalid |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P3133 |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P3133-87 |
Communication Error from Generator to Drive Motor "A" Missing Message |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P3133 |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P3134-83 |
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P3134 |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P3134-86 |
Communication Error from Drive Motor "A" to Generator Signal Invalid |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P3134 |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P3134-87 |
Communication Error from Drive Motor "A" to Generator Missing Message |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P3134 |
Refer to DTC P06B0-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P0A1A-49: Generator Control Module Internal Electronic Failure; DTC P0A1B-47: Drive Motor "A" Control Module Watchdog / Safety MC Failure; DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure; DTC P1C2A-1C: Generator A/D Converter Circuit - Circuit Voltage Out of Range; DTC P1C2A-71: Generator A/D Converter Circuit Actuator Stuck; DTC P1C2B-1C: Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range; DTC P1C2B-49: Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure; DTC P1C2B-71: Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck; DTC P1C60-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P1C62-1F: Generator Control Module Offset Power Circuit Intermittent; DTC P26DF-1C: Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range; DTC P26DF-1F: Generator Control Module Position Sensor REF Power Source Circuit Intermittent; DTC P3133-83: Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect; DTC P3133-86: Communication Error from Generator to Drive Motor "A" Signal Invalid; DTC P3133-87: Communication Error from Generator to Drive Motor "A" Missing Message; DTC P3134-83: Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect; DTC P3134-86: Communication Error from Drive Motor "A" to Generator Signal Invalid; DTC P3134-87: Communication Error from Drive Motor "A" to Generator Missing Message [03/2023 - ] |
| P314F-1F |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent |
Comes on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P314F |
Refer to DTC P314F-1F: DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent [03/2023 - ] |
| P3153-1D |
DC/DC Converter Current Sensor Circuit Current Out of Range |
Does not come on |
Master Warning: Comes on |
Motor Generator |
A |
SAE Code: P3153 |
Refer to DTC P3153-1D: DC/DC Converter Current Sensor Circuit Current Out of Range [03/2023 - ] |
| U0100-87 |
Lost Communication With ECM/PCM "A" Missing Message |
Comes on |
Master Warning: Comes on |
Motor Generator |
B |
SAE Code: U0100 |
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U0293-87: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U1170-08: Lost Communication with Brake System Control Module (ch2) Bus Signal / Message Failure; DTC U1170-87: Lost Communication With Brake System Control Module (ch2) Missing Message [03/2023 - ] |
| U0293-87 |
Lost Communication With Hybrid Powertrain Control Module Missing Message |
Comes on |
Master Warning: Comes on |
Motor Generator |
B |
SAE Code: U0293 |
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U0293-87: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U1170-08: Lost Communication with Brake System Control Module (ch2) Bus Signal / Message Failure; DTC U1170-87: Lost Communication With Brake System Control Module (ch2) Missing Message [03/2023 - ] |
| U1170-08 |
Lost Communication with Brake System Control Module (ch2) Bus Signal / Message Failure |
Does not come on |
Master Warning: Comes on |
Motor Generator |
B |
SAE Code: U1170 |
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U0293-87: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U1170-08: Lost Communication with Brake System Control Module (ch2) Bus Signal / Message Failure; DTC U1170-87: Lost Communication With Brake System Control Module (ch2) Missing Message [03/2023 - ] |
| U1170-87 |
Lost Communication With Brake System Control Module (ch2) Missing Message |
Comes on |
Master Warning: Comes on |
Motor Generator |
B |
SAE Code: U1170 |
Refer to DTC U0100-87: Lost Communication With ECM/PCM "A" Missing Message; DTC U0293-87: Lost Communication With Hybrid Powertrain Control Module Missing Message; DTC U1170-08: Lost Communication with Brake System Control Module (ch2) Bus Signal / Message Failure; DTC U1170-87: Lost Communication With Brake System Control Module (ch2) Missing Message [03/2023 - ] |
| U11B3-00 |
Lost Communication with Hybrid/EV Powertrain Control Module (ch5) (System 2) Missing Message |
Comes on |
Master Warning: Comes on |
Motor Generator |
B |
SAE Code: U11B3 |
Refer to DTC U11B3-00: Lost Communication with Hybrid/EV Powertrain Control Module (ch5) (System 2) Missing Message; DTC U11B3-87: Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message [03/2023 - ] |
| U11B3-87 |
Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message |
Comes on |
Master Warning: Comes on |
Motor Generator |
B |
SAE Code: U11B3 |
Refer to DTC U11B3-00: Lost Communication with Hybrid/EV Powertrain Control Module (ch5) (System 2) Missing Message; DTC U11B3-87: Lost Communication with Hybrid/EV Powertrain Control Module (ch5) Missing Message [03/2023 - ] |