Home >> Toyota >> 2024 >> Prius XLE AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 18 (Plug-In Charge Control System (PHEV) - Diagnostics - Introduction) >> PLUG-IN CHARGE CONTROL SYSTEM (for PHEV Model) >> Vehicle Behavior Chart [03/2023 - ] >> Vehicle Behavior Chart [03/2023 - ]
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Vehicle Behavior Chart [03/2023 - ]

WARNING: This page is about a different car, the 2025 Toyota Prius, 2024 Toyota Prius Prime, and 2023 Toyota Prius Prime. However, it is still accessible from the selected car via links, so may be relevant.
  1. VEHICLE BEHAVIOR CHART 
    1. Vehicle behavior categorized by DTC

      If a DTC is output, the vehicle behaves as follows.

      DTC No. Detection Item Vehicle Behavior when DTC is Output
      P0560-14 System Voltage (BATT) Circuit Short to Ground or Open -
      P060B-1C Plug-in Control Module A/D Processing Circuit Voltage Out of Range Charging stops / Supply power stops
      P060B-49 Plug-in Control Module A/D Processing Internal Electronic Failure Charging stops / Supply power stops
      P060B-71 Plug-in Control Module A/D Processing Actuator Stuck Charging stops / Supply power stops
      P062F-44 Plug-in Control Module EEPROM Data Memory Failure -
      P0688-1F Plug-in Control Module Power Relay Sense Circuit Intermittent Charging stops / Supply power stops
      P0D07-00 Hybrid/EV Battery Charging System Positive Contactor Stuck Closed
      1. Charging continues
      2. Solar charging, remote air conditioning, my room mode, cooling before charging, timer charging, external supply power, recovery of compressor oil from battery cooling refrigerant control: Stops
      P0D07-73 Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed
      1. Charging continues
      2. Solar charging, remote air conditioning, my room mode, cooling before charging, timer charging, external supply power, recovery of compressor oil from battery cooling refrigerant control: Stops
      P0D0E-73 Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed
      1. Charging continues
      2. Solar charging, remote air conditioning, my room mode, cooling before charging, timer charging, external supply power, recovery of compressor oil from battery cooling refrigerant control: Stops
      P0D2A-19 Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Current Above Threshold Charging stops
      P0D38-12 Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Auxiliary Battery Charging stops / Supply power stops
      P0D38-14 Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Ground or Open Charging stops / Supply power stops
      P0D38-28 Hybrid/EV Battery Charger Input Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure Charging stops / Supply power stops
      P0D38-9E Hybrid/EV Battery Charger Input Current Sensor Overcurrent Detection Circuit Stuck On Charging stops / Supply power stops
      P0D4C-1C Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range
      1. Charging stops
      2. Solar charging, remote air conditioning, my room mode, cooling before charging, timer charging, external supply power, recovery of compressor oil from battery cooling refrigerant control: Stops
      P0D4C-36 Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Signal Frequency Too Low Charging stops / Supply power stops
      P0D4C-37 Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Signal Frequency Too High Charging stops / Supply power stops
      P0D4C-9E Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Stuck On Charging stops / Supply power stops
      P0D51-12 Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit High Circuit Short to Battery Charging stops / Supply power stops
      P0D51-14 Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Low Circuit Short to Ground or Open Charging stops / Supply power stops
      P0D51-28 Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure Charging stops / Supply power stops
      P0D51-9E Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Stuck On Charging stops / Supply power stops
      P0D56-11 Charging Connector Proximity Detection Circuit Short to Ground Charging stops / Supply power stops
      P0D56-15 Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open Charging stops / Supply power stops
      P0D5C-00 Charger Input/Output Power Difference High Charging continues
      P0D5E-00 Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long
      1. Charging continues
      2. Solar charging, remote air conditioning, my room mode, cooling before charging, timer charging, external supply power, recovery of compressor oil from battery cooling refrigerant control: Stops
      P0E5E-87 Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message Charging stops / Supply power stops
      P0E61-9E Hybrid/EV Battery Charger Enable Circuit Stuck On
      1. Charging stops
      2. Solar charging, remote air conditioning, my room mode, cooling before charging, timer charging, external supply power, recovery of compressor oil from battery cooling refrigerant control: Stops
      P0E6A-73 Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed
      1. Charging continues
      2. Solar charging, remote air conditioning, my room mode, cooling before charging, timer charging, external supply power, recovery of compressor oil from battery cooling refrigerant control: Stops
      P0EF7-16 Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold Charging stops / Supply power stops
      P0EF7-17 Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold Charging stops / Supply power stops
      P0EF7-28 Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure Charging stops / Supply power stops
      P0EFB-16 Hybrid/EV Battery Charger "A" Input Voltage Sensor "C" Circuit Low Circuit Voltage Below Threshold Charging stops / Supply power stops
      P1661-00 Battery Charger "A" Inlet-Outlet Switching Contactor Stuck Open Charging stops
      P1661-73 Battery Charger "A" Inlet-Outlet Switching Contactor Actuator Stuck Closed Charging stops
      P1684-49 AC Onboard Charger Module Processor Internal Electronic Failure Charging continues / Supply power continues
      P1687-49 AC Onboard Charger Module A/D Processing Internal Electronic Failure Charging stops / Supply power stops
      P1951-62 Charger "A" DC/DC Converter Temperature Sensor (for Charging)/Hybrid/EV Output Temperature Sensor Signal Compare Failure Charging continues / Supply power continues
      P1958-16 Charger "A" Power Feeding Output Voltage Sensor Circuit Voltage Below Threshold Supply power stops
      P19AF-00 Charger "A" DC/DC Converter Malfunction (for Power Feeding) Supply power stops
      P19C5-12 Hybrid/EV Output Temperature Sensor Circuit Short to Battery Charging stops / Supply power stops
      P19C5-14 Hybrid/EV Output Temperature Sensor Circuit Short to Ground or Open -
      P19CC-19 Hybrid/EV Battery Charger Hybrid/EV Battery Output Current (ICHG) High Circuit Current Above Threshold Charging stops
      P19D0-14 Hybrid/EV Battery Charger Control Module "A" Sensor Power Supply "A" Circuit Short to Ground or Open Charging stops / Supply power stops
      P1C00-12 Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Auxiliary Battery Charging stops / Supply power stops
      P1C00-14 Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Ground or Open Charging stops / Supply power stops
      P1C00-16 Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Voltage Below Threshold Charging stops
      P1C00-9E Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On Charging stops / Supply power stops
      P1C05-12 PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery Charging stops / Supply power stops
      P1C05-14 PFC Inverter Temperature Sensor Circuit Short to Ground or Open Charging continues / Supply power continues
      P1C0A-12 DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery Charging stops / Supply power stops
      P1C0A-14 DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open Charging continues / Supply power continues
      P1C1B-00 PFC Boosting Circuit Malfunction Charging stops / Supply power stops
      P1C1C-00 DC/DC Converter Malfunction (for Charging) Charging stops
      P1C1D-00 Charging Power Low
      1. Charging stops
      2. Solar charging, remote air conditioning, my room mode, cooling before charging, timer charging, external supply power, recovery of compressor oil from battery cooling refrigerant control: Stops
      P1C1E-00 Charging Power High
      1. Charging stops
      2. Solar charging, remote air conditioning, my room mode, cooling before charging, timer charging, external supply power, recovery of compressor oil from battery cooling refrigerant control: Stops
      P1C25-62 PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure Charging continues / Supply power continues
      P1C26-17 Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Voltage Above Threshold Charging stops
      P1C27-17 Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Voltage Above Threshold Charging stops
      P1CA4-00 Charger Pre-charging Malfunction Charging stops
      P1CE9-96 Charger Cooling Fan Revolution Sensor Component Internal Failure Charging continues / Supply power continues
      P1CED-1C Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range -
      P1CF0-1C Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range -
      P1EA0-9E Solar Charger Enable Circuit Stuck On Solar charging stops
      P1EA4-1C Solar Charging Voltage Sensor Circuit Voltage Out of Range Solar charging stops
      P1EA9-17 Solar Charging Control Module Circuit Voltage Above Threshold Solar charging stops
      P308F-49 High Voltage Charging Circuit Short during Pre-Charge
      1. Charging continues
      2. Solar charging, remote air conditioning, my room mode, cooling before charging, timer charging, external supply power, recovery of compressor oil from battery cooling refrigerant control: Stops
      P309F-49 High Voltage Charging Circuit Consumption Circuit Short
      1. Charging continues
      2. Solar charging, remote air conditioning, my room mode, cooling before charging, timer charging, external supply power, recovery of compressor oil from battery cooling refrigerant control: Stops
      U0100-87 Lost Communication with ECM/PCM "A" Missing Message -
      U0155-87 Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message My room mode, timer charging, AC external supply power (HV supply mode): Stops
      U01BB-87 Lost Communication with Battery Charger Control Module "B" Missing Message Charging stops / Supply power stops
      U0293-87 Lost Communication with Hybrid/EV Powertrain Control Module Missing Message Charging continues / Battery heating continues (Other AC charging and supply power terminated, including optional features)
      U113A-87 Lost Communication with Solar Charging Control Module Missing Message Charging continues / Battery heating continues (Other AC charging and supply power terminated, including optional features)
      U1151-87 Lost Communication with Hybrid/EV Powertrain Control Module (ch3) Missing Message Charging stops / Supply power stops
      U117B-87 Lost Communication with Hybrid/EV Battery Energy Control Module "A" (ch2) Missing Message Charging stops / Supply power stops