Service Data [11/2023 - ]: Relay
RELAY
| Standard Resistance (Injector Relay (IGT/INJ)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (Electronic Driver Unit Relay (D INJ)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (No. 1 Electronic Fuel Injection Main Relay (EFI-MAIN)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (No. 2 Electronic Fuel Injection Main Relay (EFI-MAIN NO. 2)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (No. 3 Electronic Fuel Injection Main Relay (EFI-MAIN NO. 3)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| Standard Resistance (IGP Relay (IGP NO. 1)) |
3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω |