Inspection [02/2024 - ]: Procedure
- INSPECT AIR FUEL RATIO SENSOR
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Air Fuel Ratio Sensor)Standard Resistance
Tester Connection Condition Specified Condition C82-1(HA1A) - C82-2(+B) 20°C (68°F) 1.4 to 3.0 Ω C82-1(HA1A) - C82-4(A1A-) Always 10 kΩ or higher - If the result is not as specified, replace the air fuel ratio sensor.
- Measure the resistance according to the value(s) in the table below.