Typical Enabling Conditions
U0110
| Monitor runs whenever the following DTCs are not stored | C14C8: Brake system voltage circuit high U0293: Lost communication with HPCM (CH1) |
| All of the following conditions are met | A, B, C, D, E and F |
| A. Both of the following conditions a and b are met | More than 1 second |
| a. Both of the following conditions are met | More than 0.198 seconds |
| +BS cut MOS | Valid |
| +BS cut MOS voltage | Higher than 7.4 V |
| b. Both of the following conditions are met | More than 0.012 seconds |
| +BS cut MOS | Valid |
| +BS cut MOS voltage | Below 23.2 V |
| B. CAN communication status | Enable |
| C. Following condition is met | More than 3 seconds |
| IGP_PT2 voltage | Higher than 9.5 V |
| D. Following condition is met | More than 3 seconds |
| IGR voltage | Higher than 9.5 V |
| E. Following condition is met | More than 3 seconds |
| IGP_PT2 | On |
| F. +BS cut MOS voltage | Higher than 7.8 V |
U0129 AND U117D
| Monitor runs whenever the following DTCs are not stored | C14C8: Brake system voltage circuit high |
| All of the following conditions are met | A, B, C, D and E |
| A. Both of the following conditions a and b are met | More than 1 second |
| a. Both of the following conditions are met | More than 0.198 seconds |
| +BS cut MOS | Valid |
| +BS cut MOS voltage | Higher than 7.4 V |
| b. Both of the following conditions are met | More than 0.012 seconds |
| +BS cut MOS | Valid |
| +BS cut MOS voltage | Below 23.2 V |
| B. CAN communication status | Enable |
| C. Following condition is met | More than 3 seconds |
| IGR voltage | Higher than 9.5 V |
| D. Following condition is met | More than 3 seconds |
| IGR | On |
| E. +BS cut MOS voltage | Higher than 7.8 V |
U0293
| Monitor runs whenever the following DTCs are not stored | C14C8: Brake system voltage circuit high |
| All of the following conditions are met | A, B, C, D and E |
| A. Both of the following conditions a and b are met | More than 1 second |
| a. Both of the following conditions are met | More than 0.198 seconds |
| +BS cut MOS | Valid |
| +BS cut MOS voltage | Higher than 7.4 V |
| b. Both of the following conditions are met | More than 0.012 seconds |
| +BS cut MOS | Valid |
| +BS cut MOS voltage | Below 23.2 V |
| B. CAN communication status | Enable |
| C. Both of the following conditions are met | More than 3 seconds |
| IGR voltage | Higher than 9.5 V |
| IGP_PT2 voltage | Higher than 9.5 V |
| D. Both of the following conditions are met | More than 3 seconds |
| IGR | On |
| IGP_PT2 | On |
| E. +BS cut MOS voltage | Higher than 7.8 V |
U1150
| Monitor runs whenever the following DTCs are not stored | C14C8: Brake system voltage circuit high U0293: Lost communication with HPCM (CH1) |
| All of the following conditions are met | A, B, C, D, E and F |
| A. Both of the following conditions a and b are met | More than 1 second |
| a. Both of the following conditions are met | More than 0.198 seconds |
| +BS cut MOS | Valid |
| +BS cut MOS voltage | Higher than 7.4 V |
| b. Both of the following conditions are met | More than 0.012 seconds |
| +BS cut MOS | Valid |
| +BS cut MOS voltage | Below 23.2 V |
| B. CAN communication status | Enable |
| C. Both of the following conditions are met | More than 3 seconds |
| IGR voltage | Higher than 9.5 V |
| IGP_PT2 voltage | Higher than 9.5 V |
| D. Both of the following conditions are met | More than 3 seconds |
| IGR | On |
| IGP_PT2 | On |
| E. +BS cut MOS voltage | Higher than 7.8 V |