Diagnostic Trouble Code Chart [03/2023 - 01/2025]
WARNING: This page is about a different variant/trim than selected.
PLUG-IN CHARGE CONTROL SYSTEM
| DTC No. | Detection Item | MIL | Warning Indicate | DTC Output from | Priority | Note | Link |
|---|---|---|---|---|---|---|---|
| P0560-14 | System Voltage (BATT) Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0562 |
Refer to DTC P0560-14: System Voltage (BATT) Circuit Short to Ground or Open [03/2023 - ] |
| P060B-1C | Plug-in Control Module A/D Processing Circuit Voltage Out of Range | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P060B |
Refer to DTC P060B-1C: Plug-in Control Module A/D Processing Circuit Voltage Out of Range; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P060B-71: Plug-in Control Module A/D Processing Actuator Stuck [03/2023 - ] |
| P060B-49 | Plug-in Control Module A/D Processing Internal Electronic Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P060B |
Refer to DTC P060B-1C: Plug-in Control Module A/D Processing Circuit Voltage Out of Range; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P060B-71: Plug-in Control Module A/D Processing Actuator Stuck [03/2023 - ] |
| P060B-71 | Plug-in Control Module A/D Processing Actuator Stuck | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P060B |
Refer to DTC P060B-1C: Plug-in Control Module A/D Processing Circuit Voltage Out of Range; DTC P060B-49: Plug-in Control Module A/D Processing Internal Electronic Failure; DTC P060B-71: Plug-in Control Module A/D Processing Actuator Stuck [03/2023 - ] |
| P062F-44 | Plug-in Control Module EEPROM Data Memory Failure | Comes on | Master Warning: Does not come on |
Plug-in Control | A | SAE Code: P062F |
Refer to DTC P062F-44: Plug-in Control Module EEPROM Data Memory Failure [03/2023 - ] |
| P0688-1F | Plug-in Control Module Power Relay Sense Circuit Intermittent | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P2511 |
Refer to DTC P0688-1F: Plug-in Control Module Power Relay Sense Circuit Intermittent [03/2023 - ] |
| P0D07-00 | Hybrid/EV Battery Charging System Positive Contactor Stuck Closed | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D08 | Refer to DTC P0D07-00: Hybrid/EV Battery Charging System Positive Contactor Stuck Closed [03/2023 - 01/2025] |
| P0D07-73 | Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D08 | Refer to DTC P0D07-73: Hybrid/EV Battery Charging System Positive/Negative Contactor Actuator Stuck Closed [03/2023 - 01/2025] |
| P0D0E-73 | Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D0F | Refer to DTC P0D0E-73: Hybrid/EV Battery Charging System Negative Contactor Control Actuator Stuck Closed [03/2023 - 01/2025] |
| P0D2A-19 | Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Current Above Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D2A |
Refer to DTC P0D2A-19: Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Current Above Threshold [03/2023 - ] |
| P0D38-12 | Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Auxiliary Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D3B |
Refer to DTC P0D38-12: Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Auxiliary Battery; DTC P0D38-14: Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Ground or Open [03/2023 - ] |
| P0D38-14 | Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D3A |
Refer to DTC P0D38-12: Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Auxiliary Battery; DTC P0D38-14: Hybrid/EV Battery Charger Input Current Sensor Circuit - Circuit Short to Ground or Open [03/2023 - ] |
| P0D38-28 | Hybrid/EV Battery Charger Input Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D39 |
Refer to DTC P0D38-28: Hybrid/EV Battery Charger Input Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0D38-9E | Hybrid/EV Battery Charger Input Current Sensor Overcurrent Detection Circuit Stuck On | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D38 |
Refer to DTC P0D38-9E: Hybrid/EV Battery Charger Input Current Sensor Overcurrent Detection Circuit Stuck On [03/2023 - ] |
| P0D4C-1C | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D4D | Refer to DTC P0D4C-1C: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Voltage Out of Range [03/2023 - ] |
| P0D4C-36 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Signal Frequency Too Low | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D4E |
Refer to DTC P0D4C-36: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Signal Frequency Too Low [03/2023 - ] |
| P0D4C-37 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Signal Frequency Too High | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D4F |
Refer to DTC P0D4C-37: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Signal Frequency Too High [03/2023 - ] |
| P0D4C-9E | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Stuck On | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D4C |
Refer to DTC P0D4C-9E: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Stuck On [03/2023 - ] |
| P0D51-12 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit High Circuit Short to Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D54 |
Refer to DTC P0D51-12: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit High Circuit Short to Battery; DTC P0D51-14: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Low Circuit Short to Ground or Open [03/2023 - ] |
| P0D51-14 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Low Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D53 |
Refer to DTC P0D51-12: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit High Circuit Short to Battery; DTC P0D51-14: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Low Circuit Short to Ground or Open [03/2023 - ] |
| P0D51-28 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D52 |
Refer to DTC P0D51-28: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0D51-9E | Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Stuck On | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D51 |
Refer to DTC P0D51-9E: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current Sensor Circuit Stuck On [03/2023 - ] |
| P0D56-11 | Charging Connector Proximity Detection Circuit Short to Ground | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D58 |
Refer to DTC P0D56-11: Charging Connector Proximity Detection Circuit Short to Ground [03/2023 - ] |
| P0D56-15 | Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D59 |
Refer to DTC P0D56-15: Charging Connector Proximity Detection Circuit Short to Auxiliary Battery or Open [03/2023 - ] |
| P0D5C-00 | Charger Input/Output Power Difference High | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D5C |
Refer to DTC P0D5C-00: Charger Input/Output Power Difference High [03/2023 - ] |
| P0D5E-00 | Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D5E | Refer to DTC P0D5E-00: Hybrid/EV Battery Charger Hybrid/EV System Discharge Time Too Long [03/2023 - 01/2025] |
| P0E5E-87 | Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0E5E |
Refer to DTC P0E5E-87: Plug-in Control Module Processor from Hybrid/EV Battery Charger Control Module Processor Missing Message [03/2023 - ] |
| P0E61-9E | Hybrid/EV Battery Charger Enable Circuit Stuck On | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0E64 | Refer to DTC P0E61-9E: Hybrid/EV Battery Charger Enable Circuit Stuck On [03/2023 - ] |
| P0E6A-73 | Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0E6B | Refer to DTC P0E6A-73: Hybrid/EV Battery Charging System Precharge Contactor Control Actuator Stuck Closed [03/2023 - 01/2025] |
| P0EF7-16 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0EF9 |
Refer to DTC P0EF7-16: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold; DTC P0EF7-17: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold [03/2023 - ] |
| P0EF7-17 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0EFA |
Refer to DTC P0EF7-16: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Low Circuit Voltage Below Threshold; DTC P0EF7-17: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit High Circuit Voltage Above Threshold [03/2023 - ] |
| P0EF7-28 | Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0EF8 |
Refer to DTC P0EF7-28: Hybrid/EV Battery Charger Input Voltage Sensor "B" Circuit Range/Performance Signal Bias Level Out of Range / Zero Adjustment Failure [03/2023 - ] |
| P0EFB-16 | Hybrid/EV Battery Charger "A" Input Voltage Sensor "C" Circuit Low Circuit Voltage Below Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0EFD |
Refer to DTC P0EFB-16: Hybrid/EV Battery Charger "A" Input Voltage Sensor "C" Circuit Low Circuit Voltage Below Threshold [03/2023 - ] |
| P1661-00 | Battery Charger "A" Inlet-Outlet Switching Contactor Stuck Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1663 |
Refer to DTC P1661-00: Battery Charger "A" Inlet-Outlet Switching Contactor Stuck Open [03/2023 - ] |
| P1661-73 | Battery Charger "A" Inlet-Outlet Switching Contactor Actuator Stuck Closed | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1662 |
Refer to DTC P1661-73: Battery Charger "A" Inlet-Outlet Switching Contactor Actuator Stuck Closed [03/2023 - ] |
| P1684-49 | AC Onboard Charger Module Processor Internal Electronic Failure | Does not come on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1684 |
Refer to DTC P1684-49: AC Onboard Charger Module Processor Internal Electronic Failure [03/2023 - ] |
| P1687-49 | AC Onboard Charger Module A/D Processing Internal Electronic Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1687 |
Refer to DTC P1687-49: AC Onboard Charger Module A/D Processing Internal Electronic Failure [03/2023 - ] |
| P1951-62 | Charger "A" DC/DC Converter Temperature Sensor (for Charging)/Hybrid/EV Output Temperature Sensor Signal Compare Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1951 |
Refer to DTC P1951-62: Charger "A" DC/DC Converter Temperature Sensor (for Charging)/Hybrid/EV Output Temperature Sensor Signal Compare Failure [03/2023 - ] |
| P1958-16 | Charger "A" Power Feeding Output Voltage Sensor Circuit Voltage Below Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P195A |
Refer to DTC P1958-16: Charger "A" Power Feeding Output Voltage Sensor Circuit Voltage Below Threshold [03/2023 - ] |
| P19AF-00 | Charger "A" DC/DC Converter Malfunction (for Power Feeding) | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P19AF |
Refer to DTC P19AF-00: Charger "A" DC/DC Converter Malfunction (for Power Feeding) [03/2023 - ] |
| P19C5-12 | Hybrid/EV Output Temperature Sensor Circuit Short to Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P19C8 |
Refer to DTC P19C5-12: Hybrid/EV Output Temperature Sensor Circuit Short to Battery; DTC P19C5-14: Hybrid/EV Output Temperature Sensor Circuit Short to Ground or Open [03/2023 - ] |
| P19C5-14 | Hybrid/EV Output Temperature Sensor Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P19C7 |
Refer to DTC P19C5-12: Hybrid/EV Output Temperature Sensor Circuit Short to Battery; DTC P19C5-14: Hybrid/EV Output Temperature Sensor Circuit Short to Ground or Open [03/2023 - ] |
| P19CC-19 | Hybrid/EV Battery Charger Hybrid/EV Battery Output Current (ICHG) High Circuit Current Above Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P19CC |
Refer to DTC P19CC-19: Hybrid/EV Battery Charger Hybrid/EV Battery Output Current (ICHG) High Circuit Current Above Threshold [03/2023 - ] |
| P19D0-14 | Hybrid/EV Battery Charger Control Module "A" Sensor Power Supply "A" Circuit Short to Ground or Open | Does not come on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P19D1 |
Refer to DTC P19D0-14: Hybrid/EV Battery Charger Control Module "A" Sensor Power Supply "A" Circuit Short to Ground or Open [03/2023 - ] |
| P1C00-12 | Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Auxiliary Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C03 |
Refer to DTC P1C00-12: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Auxiliary Battery; DTC P1C00-14: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Ground or Open [03/2023 - ] |
| P1C00-14 | Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C02 |
Refer to DTC P1C00-12: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Auxiliary Battery; DTC P1C00-14: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Short to Ground or Open [03/2023 - ] |
| P1C00-16 | Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Voltage Below Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C01 |
Refer to DTC P1C00-16: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Voltage Below Threshold [03/2023 - ] |
| P1C00-9E | Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C00 |
Refer to DTC P1C00-9E: Voltage Sensor after Boosting by PFC Boosting Circuit Overvoltage Detection Circuit Stuck On [03/2023 - ] |
| P1C05-12 | PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C08 |
Refer to DTC P1C05-12: PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery; DTC P1C05-14: PFC Inverter Temperature Sensor Circuit Short to Ground or Open [03/2023 - ] |
| P1C05-14 | PFC Inverter Temperature Sensor Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C07 |
Refer to DTC P1C05-12: PFC Inverter Temperature Sensor Circuit Short to Auxiliary Battery; DTC P1C05-14: PFC Inverter Temperature Sensor Circuit Short to Ground or Open [03/2023 - ] |
| P1C0A-12 | DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C0D |
Refer to DTC P1C0A-12: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery; DTC P1C0A-14: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open [03/2023 - ] |
| P1C0A-14 | DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C0C |
Refer to DTC P1C0A-12: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Auxiliary Battery; DTC P1C0A-14: DC/DC Converter Temperature Sensor (for Charging) Circuit Short to Ground or Open [03/2023 - ] |
| P1C1B-00 | PFC Boosting Circuit Malfunction | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D5C |
Refer to DTC P1C1B-00: PFC Boosting Circuit Malfunction [03/2023 - ] |
| P1C1C-00 | DC/DC Converter Malfunction (for Charging) | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D5C |
Refer to DTC P1C1C-00: DC/DC Converter Malfunction (for Charging) [03/2023 - ] |
| P1C1D-00 | Charging Power Low | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D5C |
Refer to DTC P1C1D-00: Charging Power Low [03/2023 - ] |
| P1C1E-00 | Charging Power High | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P0D5C |
Refer to DTC P1C1E-00: Charging Power High [03/2023 - ] |
| P1C25-62 | PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C25 |
Refer to DTC P1C25-62: PFC Inverter Temperature Sensor/DC/DC Converter for Charging Temperature Sensor Signal Compare Failure [03/2023 - ] |
| P1C26-17 | Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Voltage Above Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P1C26 |
Refer to DTC P1C26-17: Hybrid/EV Battery Charger Hybrid/EV Battery Input Voltage Sensor Circuit Voltage Above Threshold [03/2023 - ] |
| P1C27-17 | Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Voltage Above Threshold | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1C27 |
Refer to DTC P1C27-17: Voltage Sensor after Boosting by PFC Boosting Circuit - Circuit Voltage Above Threshold [03/2023 - ] |
| P1CA4-00 | Charger Pre-charging Malfunction | Comes on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P0D5C |
Refer to DTC P1CA4-00: Charger Pre-charging Malfunction [03/2023 - ] |
| P1CE9-96 | Charger Cooling Fan Revolution Sensor Component Internal Failure | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P1CEA |
Refer to DTC P1CE9-96: Charger Cooling Fan Revolution Sensor Component Internal Failure [03/2023 - ] |
| P1CED-1C | Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range | Does not come on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1CED |
Refer to DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range [03/2023 - ] |
| P1CF0-1C | Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range | Does not come on | Master Warning: Comes on |
Plug-in Control | A | SAE Code: P1CF0 |
Refer to DTC P1CED-1C: Plug-in Control ECU Power Supply (Plus) Circuit Voltage Out of Range; DTC P1CF0-1C: Plug-in Control ECU Power Supply (Minus) Circuit Voltage Out of Range [03/2023 - ] |
| P1EA0-9E | Solar Charger Enable Circuit Stuck On | Does not come on | Solar Charging Warning Light: Comes on |
Plug-in Control | B | SAE Code: P1EA3 | Refer to DTC P1EA0-9E: Solar Charger Enable Circuit Stuck On [03/2023 - ] |
| P1EA4-1C | Solar Charging Voltage Sensor Circuit Voltage Out of Range | Does not come on | Solar Charging Warning Light: Comes on |
Plug-in Control | B | SAE Code: P1EA5 | Refer to DTC P1EA4-1C: Solar Charging Voltage Sensor Circuit Voltage Out of Range [03/2023 - ] |
| P1EA9-17 | Solar Charging Control Module Circuit Voltage Above Threshold | Does not come on | Solar Charging Warning Light: Comes on |
Plug-in Control | B | SAE Code: P1EA9 | Refer to DTC P1EA9-17: Solar Charging Control Module Circuit Voltage Above Threshold [03/2023 - ] |
| P308F-49 | High Voltage Charging Circuit Short during Pre-Charge | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P308F | Refer to DTC P308F-49: High Voltage Charging Circuit Short during Pre-Charge [03/2023 - 01/2025] |
| P309F-49 | High Voltage Charging Circuit Consumption Circuit Short | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: P309F | Refer to DTC P309F-49: High Voltage Charging Circuit Consumption Circuit Short [03/2023 - 01/2025] |
| U0100-87 | Lost Communication with ECM/PCM "A" Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U0100 |
Refer to DTC U0100-87: Lost Communication with ECM/PCM "A" Missing Message; DTC U0155-87: Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message; DTC U0293-87: Lost Communication with Hybrid/EV Powertrain Control Module Missing Message [03/2023 - ] |
| U0155-87 | Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message | Does not come on | Master Warning: Does not come on |
Plug-in Control | B | SAE Code: U0155 |
Refer to DTC U0100-87: Lost Communication with ECM/PCM "A" Missing Message; DTC U0155-87: Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message; DTC U0293-87: Lost Communication with Hybrid/EV Powertrain Control Module Missing Message [03/2023 - ] |
| U01BB-87 | Lost Communication with Battery Charger Control Module "B" Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U01BB | Refer to DTC U01BB-87: Lost Communication with Battery Charger Control Module "B" Missing Message [03/2023 - ] |
| U0293-87 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U0293 |
Refer to DTC U0100-87: Lost Communication with ECM/PCM "A" Missing Message; DTC U0155-87: Lost Communication with Instrument Panel Cluster (IPC) Control Module Missing Message; DTC U0293-87: Lost Communication with Hybrid/EV Powertrain Control Module Missing Message [03/2023 - ] |
| U113A-87 | Lost Communication with Solar Charging Control Module Missing Message | Does not come on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U113A |
Refer to DTC U113A-87: Lost Communication with Solar Charging Control Module Missing Message [03/2023 - ] |
| U1151-87 | Lost Communication with Hybrid/EV Powertrain Control Module (ch3) Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U1151 |
Refer to DTC U1151-87: Lost Communication with Hybrid/EV Powertrain Control Module (ch3) Missing Message [03/2023 - ] |
| U117B-87 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" (ch2) Missing Message | Comes on | Master Warning: Comes on |
Plug-in Control | B | SAE Code: U117B |
Refer to DTC U117B-87: Lost Communication with Hybrid/EV Battery Energy Control Module "A" (ch2) Missing Message [03/2023 - ] |