Customize Parameters [10/2022 - ]
- CUSTOMIZE HYBRID CONTROL SYSTEM
The following items can be customized.
NOTE:- When the customer requests a change in a function, first make sure that the function can be customized.
- Be sure to make a note of the current settings before customizing.
- When troubleshooting a function, first make sure that the function is set to the default setting.
- Customizing with the multi-information display
- Turn the ignition switch to ON.
- Select the setting tab in the multi-information display.
- Enter the following menus: Vehicle Settings / Charge settings.
- Select the setting by referring to the table below.
Display Description Default Setting Relevant ECU Charge schedule Setting the timer charging. - - Scheduled Events
- Charge Now
- Next Charging Event
Electric vehicle charger assembly Charge current Changing the upper limit of the charging current. MAX - for 3.5 kW Type:
MAX / 8 A
- for 7 kW Type:
MAX / 16 A / 8 A
Connector Lock Changing the charging connector lock settings. Auto Lock Auto Lock / Auto Lock & Unlock / OFF Battery heater Setting "HV Supply Battery Heater" on/off. ON ON / OFF Battery ECU assembly Battery Cooler Setting "HV Supply Battery Cooler" on/off. ON ON / OFF
- Customizing with the radio and display receiver assembly
- Turn the ignition switch to ON.
- Enter the following menus: MENU / Info / Charge Schedule.
- Select the setting by referring to the table below.
Display Description Default Setting Relevant ECU Charge schedule Setting the timer charging. - - Scheduled Events
- Charge Now
- Next Charging Event
Electric vehicle charger assembly