Inspection [12/2023 - ]: Procedure
- INSPECT ECO RUN CANCEL SWITCH ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition Result J24-5 (ECU) - J24-2 (E) Eco run cancel switch assembly being pushed and held Below 1 Ω Ω J24-5 (ECU) - J24-2 (E) Eco run cancel switch assembly not pushed 10 kΩ or higher kΩ If the result is not as specified, replace the eco run cancel switch assembly.
*a Component without harness connected
(Eco Run Cancel Switch Assembly) - Apply auxiliary battery voltage between the terminals of the switch, and check the illumination condition of the eco run cancel switch assembly.
OK
Measurement Condition Specified Condition Auxiliary battery positive (+) → J24-6 (ILL+)
Auxiliary battery negative (-) → J24-1 (ILL-)Illuminates If the result is not as specified, replace the eco run cancel switch assembly.
*a Component without harness connected
(Eco Run Cancel Switch Assembly)
- Measure the resistance according to the value(s) in the table below.