LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volkswagen >> 1969 >> Fastback Eng CD AD, Not Available Trans >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generators >> Testing >> On Car Test >> Testing Generator Without Regulator (Quick Check)
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Testing Generator Without Regulator (Quick Check)

  1. Disconnect both leads (D+ and DF) from generator. Connect terminal DF of generator to ground (D-).
  2. Connect positive lead of voltmeter to large connector (D+) of generator and the negative lead to the D-terminal.
  3. Run generator briefly at the following speeds. The voltage supplied by the generator must be as follows:
    RPM 6V Units 12V Units
    1500 6V 12V
    3000 18V 36V
    VOLKSWAGEN GENERATOR & REGULATOR SPECIFICATIONS

    VW Part No Reg. Part No Nominal Data Cut-in Speed RPM Cut-in Voltage Return Current Amps No-Load Reg. Voltage Load Reg. Voltage Load Current Amps.
    Max. Amps. Mean Reg. Volts Output RPM
    113 903 021C 113 903 801C 45 6.8 2400 1500 6.2-6.8 2.0-9.0 7.4-8.1 6.4-7.3 34
    211 903 031 211 903 803 30 14 2000 1450 12.4-13.1 2.0-7.5 13.5-14.5 12.8-13.8 45
    211 903 031A 21 1 903 803B 30 14 2000 1450 12.4-13.1 2.0-7.5 13.5-14.5 12.8-13.8 45
    113 903 031G 113 903 803E 30 14 2000 1450 12.4-13.1 2.0-7.5 13.5-14.5 12.8-13.8 45
    211 903 031 211 903 803 30 14 2000 1450 12.4-13.1 2.0-7.5 13.5-14.5 12.8-13.8 45
    211 903 031A 211 903 803B 30 14 2000 1450 12.4-13.1 2.0-7.5 13.5-14.5 12.8-13.8 45
    113 903 031G 113 903 803E 30 14 2000 1450 12.4-13.1 2.0-7.5 13.5-14.5 12.8-13.8 45
    211 903 03 ID 211 903 803E 38 14 2000 1300 12.5-13.2 5.0-11.5 13.5-14.2 12.9-13.6 35
    311 903 031E 211 903 803 and B 30 14 2000 1450 12.4-13.1 2.0-7.5 13.5-14.5 12.8-13.8 45
    311 903 031F 113 903 803E 30 14 2000 1450 12.4-13.1 2.0-7.5 13.5-14.5 12.8-13.8 45
  4. If the generator supplies no voltage or too little voltage, it must be removed and checked.
    Fig 1: Testing Generator Without Regulator
    G09319090Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.