Display group 33
Fig 1: Display Group 33 - Oxygen Sensor (O2S) Control - Oxygen Sensor (O2S) Learned Values Before Three Way Catalytic Converter
NOTE:
In the previous graphic, for Evaluation, refer to:
Note on display zone 1:
The display must swing around 0.0%. If 0.0% is constantly displayed, the Oxygen Sensor (O2S) control has switched from control to control because a malfunction has occurred in the Oxygen Sensor (O2S) control. Check DTC memory. See DTC memory, checking and erasing .