LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Volkswagen >> 2017 >> Golf R Standard Trans >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Drivers Assistance Systems - ADAS >> Driver Assistance Systems Front Camera Calibration >> Driver Assistance Systems Front Camera >> Driver Assistance Systems Front Camera, Calibrating
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Driver Assistance Systems Front Camera, Calibrating

Special tools and workshop equipment required 

If the camera lens is obstructed by a lot of dirt on the inside, then lens must be cleaned by hand. To do this, remove the control module and the lens, and clean the windshield using Cleaning Solution. Remove the control module and the lens  . Refer to Driver Assistance Systems Front Camera, Removing and Installing

The calibration must be correct for the Driver Assistance Systems Front Camera - R242- to function correctly. 

The Driver Assistance Systems Front Camera - R242- must be calibrated again for the following reasons: 

NOTE:
  • Before calibrating the driver assistance systems front camera, check the DTC memory and correct any faults.
  • The driver assistance systems front camera may only be calibrated using alignment equipment approved by VW/Audi.
  • Only the - VAS6430/1- may be used to calibrate the driver assistance systems front camera.
NOTE:
  • The Driver Assistance Systems Front Camera - R242- must fit correctly in the bracket.
  • The camera viewing range must be clean and unobstructed.
  • Before driving the vehicle onto the vehicle alignment platform, make sure there is sufficient space between the center of the wheel hub on the front wheels and the - VAS6430/1-.
  • The distance between the - VAS6430/1- and the center of the wheel hub on the front wheels must be 1, 500 mm ± 25 mm.
  • If there is not sufficient space, drive the vehicle backward onto the alignment stand in order to use the corresponding space.
  • The calibration board must be positioned in the center of the setting device.
  • Check the DTC memory before calibrating. Erase any entries if necessary.
NOTE: During the calibration procedure, make sure all the vehicle doors remain closed and the vehicle exterior lamps are switched off.
NOTE:
  • The -VAS6430/1- must not be moved on the calibration beam.
  • The alignment stand must be in the lowest level position for the next step.
G12354057Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
  1. Distance measuring unit with spring tape measure and mounting pin
    • Position the -VAS6430/1- at a distance -a- of 1500 mm ± 25 mm from the center of the wheel hub on the front wheels to the beam on the -VAS6430/1-.
      CAUTION:
      • Distance -a- 1, 500 mm ± 25 mm must be measured on both side of the vehicle and then the - VAS66430/1- must be aligned.
      • Distance -a- must be the same on both sides of the vehicle.
    • Mount the front wheel measuring sensors -1- to the - VAS6430/1-.
      G12354058Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
      G12354049Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
    • Determine the height value -a- between the -VAS6430/1- contact patch and the wheel contact surface on the vehicle alignment platform. Enter the determined value in the wheel alignment computer.
      G12354060Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
    • Loosen the clamping bolt -arrow- and place the measuring bar -1- on the floor.
      G12354061Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.
    • Turn the crank -1- to adjust the -VAS6430/4- to the height specification -2- and then make a note of it.
      G12354062Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

If the specified height was reached, then the measuring bar -1- must be pushed slightly forward and secured with the locking bolt -arrow-. 

G12354061Courtesy of VOLKSWAGEN GROUP OF AMERICA, INC.

If the specified height was reached, then the measuring bar -1- must be pushed slightly forward and secured with the locking bolt -arrow-. 

Perform any subsequent work using the Vehicle Diagnostic Tester. 

Follow the instructions on the screen to perform the calibration.

NOTE: Next, in guided fault finding  , determine the height of the body.