Basic Adjustment Of Pressure Regulator Push Rod
- Remove locking circlip from end of push rod. Connect Pressure Gauge (5230 ) and Pressure Tester (5496 ) to pressure regulator. See Fig 1 . Increase pressure to 7.0-7.8 psi (.49-.54 kg/cm2 ). Press wastegate lever against turbine housing, closing wastegate valve.
- Adjust push rod length so push rod fits exactly over wastegate valve lever. Install locking circlip, and tighten push rod lock nut. Remove pressure gauge and tester.